3 resultados para traffic fuel
em Universitätsbibliothek Kassel, Universität Kassel, Germany
Resumo:
A stand-alone power system is an autonomous system that supplies electricity to the user load without being connected to the electric grid. This kind of decentralized system is frequently located in remote and inaccessible areas. It is essential for about one third of the world population which are living in developed or isolated regions and have no access to an electricity utility grid. The most people live in remote and rural areas, with low population density, lacking even the basic infrastructure. The utility grid extension to these locations is not a cost effective option and sometimes technically not feasible. The purpose of this thesis is the modelling and simulation of a stand-alone hybrid power system, referred to as “hydrogen Photovoltaic-Fuel Cell (PVFC) hybrid system”. It couples a photovoltaic generator (PV), an alkaline water electrolyser, a storage gas tank, a proton exchange membrane fuel cell (PEMFC), and power conditioning units (PCU) to give different system topologies. The system is intended to be an environmentally friendly solution since it tries maximising the use of a renewable energy source. Electricity is produced by a PV generator to meet the requirements of a user load. Whenever there is enough solar radiation, the user load can be powered totally by the PV electricity. During periods of low solar radiation, auxiliary electricity is required. An alkaline high pressure water electrolyser is powered by the excess energy from the PV generator to produce hydrogen and oxygen at a pressure of maximum 30bar. Gases are stored without compression for short- (hourly or daily) and long- (seasonal) term. A proton exchange membrane (PEM) fuel cell is used to keep the system’s reliability at the same level as for the conventional system while decreasing the environmental impact of the whole system. The PEM fuel cell consumes gases which are produced by an electrolyser to meet the user load demand when the PV generator energy is deficient, so that it works as an auxiliary generator. Power conditioning units are appropriate for the conversion and dispatch the energy between the components of the system. No batteries are used in this system since they represent the weakest when used in PV systems due to their need for sophisticated control and their short lifetime. The model library, ISET Alternative Power Library (ISET-APL), is designed by the Institute of Solar Energy supply Technology (ISET) and used for the simulation of the hybrid system. The physical, analytical and/or empirical equations of each component are programmed and implemented separately in this library for the simulation software program Simplorer by C++ language. The model parameters are derived from manufacturer’s performance data sheets or measurements obtained from literature. The identification and validation of the major hydrogen PVFC hybrid system component models are evaluated according to the measured data of the components, from the manufacturer’s data sheet or from actual system operation. Then, the overall system is simulated, at intervals of one hour each, by using solar radiation as the primary energy input and hydrogen as energy storage for one year operation. A comparison between different topologies, such as DC or AC coupled systems, is carried out on the basis of energy point of view at two locations with different geographical latitudes, in Kassel/Germany (Europe) and in Cairo/Egypt (North Africa). The main conclusion in this work is that the simulation method of the system study under different conditions could successfully be used to give good visualization and comparison between those topologies for the overall performance of the system. The operational performance of the system is not only depending on component efficiency but also on system design and consumption behaviour. The worst case of this system is the low efficiency of the storage subsystem made of the electrolyser, the gas storage tank, and the fuel cell as it is around 25-34% at Cairo and 29-37% at Kassel. Therefore, the research for this system should be concentrated in the subsystem components development especially the fuel cell.
Resumo:
Energy production from biomass and the conservation of ecologically valuable grassland habitats are two important issues of agriculture today. The combination of a bioenergy production, which minimises environmental impacts and competition with food production for land with a conversion of semi-natural grasslands through new utilization alternatives for the biomass, led to the development of the IFBB process. Its basic principle is the separation of biomass into a liquid fraction (press fluid, PF) for the production of electric and thermal energy after anaerobic digestion to biogas and a solid fraction (press cake, PC) for the production of thermal energy through combustion. This study was undertaken to explore mass and energy flows as well as quality aspects of energy carriers within the IFBB process and determine their dependency on biomass-related and technical parameters. Two experiments were conducted, in which biomass from semi-natural grassland was conserved as silage and subjected to a hydrothermal conditioning and a subsequent mechanical dehydration with a screw press. Methane yield of the PF and the untreated silage was determined in anaerobic digestion experiments in batch fermenters at 37°C with a fermentation time of 13-15 and 27-35 days for the PF and the silage, respectively. Concentrations of dry matter (DM), ash, crude protein (CP), crude fibre (CF), ether extract (EE), neutral detergent fibre (NDF), acid detergent fibre (ADF), acid detergent ligning (ADL) and elements (K, Mg, Ca, Cl, N, S, P, C, H, N) were determined in the untreated biomass and the PC. Higher heating value (HHV) and ash softening temperature (AST) were calculated based on elemental concentration. Chemical composition of the PF and mass flows of all plant compounds into the PF were calculated. In the first experiment, biomass from five different semi-natural grassland swards (Arrhenaterion I and II, Caricion fuscae, Filipendulion ulmariae, Polygono-Trisetion) was harvested at one late sampling (19 July or 31 August) and ensiled. Each silage was subjected to three different temperature treatments (5°C, 60°C, 80°C) during hydrothermal conditioning. Based on observed methane yields and HHV as energy output parameters as well as literature-based and observed energy input parameters, energy and green house gas (GHG) balances were calculated for IFBB and two reference conversion processes, whole-crop digestion of untreated silage (WCD) and combustion of hay (CH). In the second experiment, biomass from one single semi-natural grassland sward (Arrhenaterion) was harvested at eight consecutive dates (27/04, 02/05, 09/05, 16/05, 24/05, 31/05, 11/06, 21/06) and ensiled. Each silage was subjected to six different treatments (no hydrothermal conditioning and hydrothermal conditioning at 10°C, 30°C, 50°C, 70°C, 90°C). Energy balance was calculated for IFBB and WCD. Multiple regression models were developed to predict mass flows, concentrations of elements in the PC, concentration of organic compounds in the PF and energy conversion efficiency of the IFBB process from temperature of hydrothermal conditioning as well as NDF and DM concentration in the silage. Results showed a relative reduction of ash and all elements detrimental for combustion in the PC compared to the untreated biomass of 20-90%. Reduction was highest for K and Cl and lowest for N. HHV of PC and untreated biomass were in a comparable range (17.8-19.5 MJ kg-1 DM), but AST of PC was higher (1156-1254°C). Methane yields of PF were higher compared to those of WCD when the biomass was harvested late (end of May and later) and in a comparable range when the biomass was harvested early and ranged from 332 to 458 LN kg-1 VS. Regarding energy and GHG balances, IFBB, with a net energy yield of 11.9-14.1 MWh ha-1, a conversion efficiency of 0.43-0.51, and GHG mitigation of 3.6-4.4 t CO2eq ha-1, performed better than WCD, but worse than CH. WCD produces thermal and electric energy with low efficiency, CH produces only thermal energy with a low quality solid fuel with high efficiency, IFBB produces thermal and electric energy with a solid fuel of high quality with medium efficiency. Regression models were able to predict target parameters with high accuracy (R2=0.70-0.99). The influence of increasing temperature of hydrothermal conditioning was an increase of mass flows, a decrease of element concentrations in the PC and a differing effect on energy conversion efficiency. The influence of increasing NDF concentration of the silage was a differing effect on mass flows, a decrease of element concentrations in the PC and an increase of energy conversion efficiency. The influence of increasing DM concentration of the silage was a decrease of mass flows, an increase of element concentrations in the PC and an increase of energy conversion efficiency. Based on the models an optimised IFBB process would be obtained with a medium temperature of hydrothermal conditioning (50°C), high NDF concentrations in the silage and medium DM concentrations of the silage.
Resumo:
Diese Arbeit behandelt Controlled Traffic Farming (CTF) Anbausysteme, bei denen für alle Arbeitsgänge satellitengesteuert immer dieselben Fahrspuren benutzt werden. Lässt sich mit CTF die Belastung des Bodens verringern und die Effizienz von Direktsaat-Anbausystemen steigern? Neben agronomischen und bodenphysikalischen Parametern wurden Auswirkungen von Lenksystemen und Umsetzungsmöglichkeiten von CTF in die Praxis untersucht. Die Analyse einer CTF-Umsetzung unter europäischen Bedingungen mit der Verwendung von Standardmaschinen zeigte, dass sich CTF-Anbausysteme mit den heute zur Verfügung stehenden Maschinen für Dauergrünland, Mähdruschfrüchte und Mais auf kleiner und grösser strukturierten Flächen relativ einfach mechanisieren lassen. Bei Zuckerrüben und Kartoffeln können Kompromisse notwendig sein. Generell erfordern CTF-Anbausysteme eine sorgfältige Planung und Umsetzung in die Praxis. Im dreijährigen Feldversuch (Winterweizen, Wintergerste, Kunstwiese mit Kleegrasmischung) auf einem Lehmboden wurde CTF-Direktsaat mit konventionell zufällig befahrenen Direktsaat- und Pflugverfahren verglichen. Unter CTF zeigte sich eine Differenzierung der nicht, gering und intensiv befahrenen Varianten. Auf dem vorliegenden kompakten Boden mit 1150 mm Jahresniederschlag waren die Unterschiede zwischen den nicht befahrenen Flächen und den mit niedrigem Kontaktflächendruck befahrenen Flächen eher gering. In den nicht befahrenen Flächen entwickelten Eindringwiderstand und Kohlendioxidgehalt der Bodenluft nach drei Jahren signifikant bessere Werte. Bodendichte und Porosität zeigten hingegen keinen eindeutig interpretierbaren Trend. Aufgrund teils suboptimaler Feldaufgänge liess sich keine generelle agronomische Tendenz ableiten. Die intensive Befahrung der Pflegefahrgassen zeigte allerdings klar negative bodenkundliche und planzenbauliche Auswirkungen. Es bietet sich daher an, vor allem für Pflegearbeiten permanent dieselben Fahrspuren zu nutzen. In der Untersuchung zu den Auswirkungen von Lenksystemen zeigten sich signifikante Vorteile von Lenksystemen in einer Verminderung der Fahrerbelastung und einer höheren Lenkgenauigkeit vor allem bei grossen Arbeitsbreiten ohne Spuranreisser. Die meisten anderen Messparameter waren mit Lenksystem leicht vorteilhafter als ohne, unterschieden sich aber nicht signifikant voneinander. Fahrer und naturräumliche Gegebenheiten wie die Schlagform hatten einen wesentlich grösseren Einfluss. Gesamthaft betrachtet erweitert CTF in Kombination mit weiteren Bodenschutzmass-nahmen die Möglichkeiten, Bodenverdichtungen zu vermeiden, den Bedarf an energieintensiver Bodenlocke-rung zu reduzieren und die Entwicklung einer stabileren Bodenstruktur mit höherer Tragfähigkeit zu fördern. Zusammen mit einer an Kultur und Anbausystem angepassten Saatbettbereitung und den in geraden Reihen einfacher durchführbaren mechanischen Pflegemassnahmen ergeben sich gute Voraussetzungen für die Gestaltung agronomisch leistungsfähiger und ökologisch nachhaltiger Anbausysteme.