5 resultados para chains with unbounded variable length memory

em Universitätsbibliothek Kassel, Universität Kassel, Germany


Relevância:

100.00% 100.00%

Publicador:

Resumo:

We have studied the transport properties of disordered one-dimensional two-band systems. The model includes a narrow d band hybridised with an s band. The Landauer formula was used in the case of a very narrow d band or in the case of short chains. The results were compared with the localisation length of the wavefunctions calculated by the transfer matrix method, which allows the use of very lang chains, and an excellent agreement was obtained.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In dieser Arbeit wurden elektronische Eigenschaften der sogenannten Spiroverbin-dungen untersucht, die aus zwei durch ein gemeinsames Spiro-Kohlenstoffatom miteinander verbundenen π-Systemen bestehen. Solche Untersuchungen sind notwendig, um die gezielte Synthese organischer Materialien mit bestimmten optischen, elektrischen, photoelektrischen oder magnetischen Eigenschaften zu ermöglichen. Im einzelnen wurden mit Hilfe der Cyclovoltammetrie, Square-Wave-Voltammetrie und Spektroelektrochemie eine Reihe homologer Spiro-p-oligophenyle, sowie symmetrisch und unsymmetrisch substituierte Spiroverbindungen und Spirocyclopentadithiophene unter-sucht. Dabei ergaben sich folgende Einflussfaktoren: Kettenlänge, verschiedene Substituenten (Trimethylsilyl, tert-Butyl, Fluor, Pyridyl, perfluoriertes Pyridyl, Dimethylamino-Gruppe), verschiedene Positionen der Substitution, Lage der Spiroverknüpfung und Art des π-Systems im Spirokern. Die elektronischen Eigenschaften der untersuchten Verbindungen variieren systema-tisch mit der Kettenlänge. So vermindert sich der Betrag der Redoxpotentiale der Spiroverbin-dungen mit Zunahme der Kettenlänge, während die Anzahl der übertragenen Elektronen mit zunehmender Kettenlänge wächst. Die Absorption der neutralen und geladenen Spezies ver-schiebt sich mit steigender Kettenlänge bathochrom. Der Substituenteneinfluss auf die Poten-tiallage hängt davon ab, welcher der Effekte +I, -I, +M, -M überwiegt; dabei spielt auch die Position der Substitution eine Rolle. Weiter lässt sich der Einfluss der Lage der Spiroverknüpfung auf die Redoxpotentiale mit der verschiedenen Coulomb-Abstoßung innerhalb oder/und zwischen Phenylketten bei symmetrisch und unsymmetrisch verknüpften Spiroverbindungen begründen. Schließlich wurden die Redoxmechanismen der untersuchten Spiroverbindungen er-mittelt. Die meisten Verbindungen werden zum Bis(radikalion) reduziert bzw. oxidiert (Me-chanismus A). Nur wenige Verbindungen werden nach Mechanismus B reduziert, in dem das Elektron unter Bildung eines Dianions in die schon einfach reduzierte Molekülhälfte über-geht. Die Unterschiede der Redoxpotentiale, der Lage der Absorption, des Reduktionsme-chanismus der Verbindungen mit unterschiedlichen Spirokernen (Spirobifluoren und Spiro-cyclopentadithiophen) konnten mit den unterschiedlichen elektronischen Strukturen von Phe-nyl- und Thiophenring (aromatisches und heteroaromatisches π System) erklärt werden.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In der vorliegenden Arbeit wurden neue symmetrische Spiro-p-oligophenyle der allgemeinen Form Spiro-o-Φ[n,n] mit der Gesamtkettenlänge o=2n+2 Phenylringen (o > 10) und der Zahl n der Phenylringe in den p-Oligophenylsubstituenten am Spirobifluorenkern, dargestellt. Neben den symmetrischen Verbindungen wurden erstmals auch unsymmetrische Spiro-p-oligophenyle der allgemeinen Form Spiro-o-Φ[n,m] mit o=n+m+2 (o = 3-7) und n ≠ m synthetisiert. Aufgrund der sehr geringen Löslichkeit der größeren Verbindungen wurden löslichkeitssteigernde Substituenten an den endständigen Phenylringen angebracht. Bei den Verbindungen, die mit Trimethylsilyl-Gruppen (TMS-) in den endständigen meta-Positionen „3“ und „5“ substituiert wurden, konnte die Löslichkeit um mehrere Größenordnungen gesteigert werden, sodass die Darstellung der symmetrischen Verbindungen bis zu einer Kettenlänge von 16 Phenylringen möglich wurde. Nach erfolgreicher Synthese und Aufreinigung wurden die TMS-Gruppen wieder entfernt und die erhaltenen, unsubstituierten Verbindungen charakterisiert. Zusätzlich wurden auch die TMS-Derivate untersucht. Zur Charakterisierung zählten neben der Reinheits- und Strukturanalytik unter anderem auch spektroskopische (UV/Vis-Absorption, Fluoreszenz, Fluoreszenzquantenausbeute), elektrochemische (Cyclovoltammetrie) und thermische (Thermogravimetrie, Dynamische Differenzkalorimetrie) Untersuchungen. Hier wurde unter anderem der Einfluss der Kettenlänge und der Position der Spiroverknüpfung auf isomere Verbindungen gleicher Kettenlänge untersucht. Bei den spektroskopischen Messungen konnte eine Konvergenz der längstwelligen Absorptionsbanden, bzw. kürzestwelligen Fluoreszenzbanden mit zunehmender Kettenlänge beobachtet werden. Die effektive Konjugationslänge konnte so aus experimentellen Daten bestimmt werden zu 12 Phenylringen in der Absorption und 14 Phenylringen in der Fluoreszenz. Bei den Isomeren gleicher Kettenlänge zeigte sich in der Absorption eine hypsochrome Verschiebung der Absorptionsmaxima mit zunehmender Verschiebung der Spiroverknüpfung zum Kettenende hin, während die Position der Spiroverknüpfung keinen messbaren Einfluss auf die Verschiebung der Fluoreszenzbanden hatte. Die Substitution mit TMS in den meta-Positionen zeigte keinen messbaren Einfluss auf die Absorptions- bzw. Fluoreszenzbanden. Die elektrochemischen Untersuchungen zeigten mit zunehmender Kettenlänge eine erleichterte Oxidation und Reduktion, während bei Isomeren gleicher Kettenlänge die Oxidation mit Verschiebung der Spiroverknüpfung zum Kettenende hin erschwert und die Reduktion erleichtert war. Die thermogravimetrischen Analysen (TGA) zeigten eine außerordentlich hohe thermische Stabilität (5% Massenabnahme unter Schutzgas) der Spiro-p-oligophenyle von Td,5% = 474°C bei Spiro-5Φ[1,2] bis 570°C bei Spiro 8Φ[3,3]. Ebenso blieben hohe Rückstandsmassen unter Schutzgas bei 850°C zurück, wie das Beispiel Spiro 8Φ[3,3] mit 68% zeigt. Die Verbindungen zeigten hohe Schmelzpunkte (max. 496°C bei Spiro-6Φ[0,4]) und Glasübergangstemperaturen (max. 434°C bei p-TMS-Spiro-8Φ[3,3]). Viele der Verbindungen, besonders die in den meta-Positionen TMS-substituierten Verbindungen, bildeten stabile amorphe Gläser.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the vision of Mark Weiser on ubiquitous computing, computers are disappearing from the focus of the users and are seamlessly interacting with other computers and users in order to provide information and services. This shift of computers away from direct computer interaction requires another way of applications to interact without bothering the user. Context is the information which can be used to characterize the situation of persons, locations, or other objects relevant for the applications. Context-aware applications are capable of monitoring and exploiting knowledge about external operating conditions. These applications can adapt their behaviour based on the retrieved information and thus to replace (at least a certain amount) the missing user interactions. Context awareness can be assumed to be an important ingredient for applications in ubiquitous computing environments. However, context management in ubiquitous computing environments must reflect the specific characteristics of these environments, for example distribution, mobility, resource-constrained devices, and heterogeneity of context sources. Modern mobile devices are equipped with fast processors, sufficient memory, and with several sensors, like Global Positioning System (GPS) sensor, light sensor, or accelerometer. Since many applications in ubiquitous computing environments can exploit context information for enhancing their service to the user, these devices are highly useful for context-aware applications in ubiquitous computing environments. Additionally, context reasoners and external context providers can be incorporated. It is possible that several context sensors, reasoners and context providers offer the same type of information. However, the information providers can differ in quality levels (e.g. accuracy), representations (e.g. position represented in coordinates and as an address) of the offered information, and costs (like battery consumption) for providing the information. In order to simplify the development of context-aware applications, the developers should be able to transparently access context information without bothering with underlying context accessing techniques and distribution aspects. They should rather be able to express which kind of information they require, which quality criteria this information should fulfil, and how much the provision of this information should cost (not only monetary cost but also energy or performance usage). For this purpose, application developers as well as developers of context providers need a common language and vocabulary to specify which information they require respectively they provide. These descriptions respectively criteria have to be matched. For a matching of these descriptions, it is likely that a transformation of the provided information is needed to fulfil the criteria of the context-aware application. As it is possible that more than one provider fulfils the criteria, a selection process is required. In this process the system has to trade off the provided quality of context and required costs of the context provider against the quality of context requested by the context consumer. This selection allows to turn on context sources only if required. Explicitly selecting context services and thereby dynamically activating and deactivating the local context provider has the advantage that also the resource consumption is reduced as especially unused context sensors are deactivated. One promising solution is a middleware providing appropriate support in consideration of the principles of service-oriented computing like loose coupling, abstraction, reusability, or discoverability of context providers. This allows us to abstract context sensors, context reasoners and also external context providers as context services. In this thesis we present our solution consisting of a context model and ontology, a context offer and query language, a comprehensive matching and mediation process and a selection service. Especially the matching and mediation process and the selection service differ from the existing works. The matching and mediation process allows an autonomous establishment of mediation processes in order to transfer information from an offered representation into a requested representation. In difference to other approaches, the selection service selects not only a service for a service request, it rather selects a set of services in order to fulfil all requests which also facilitates the sharing of services. The approach is extensively reviewed regarding the different requirements and a set of demonstrators shows its usability in real-world scenarios.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Das Gesundheitsmanagement von Milchkühen hat in den vergangenen Jahren auf den landwirtschaftlichen Betrieben an Bedeutung gewonnen. Neben Präventionsmaßnahmen zur Gesunderhaltung der Tiere ist die frühzeitige und systematische Erkennung von Erkrankungen hierbei der Hauptbestandteil. Es zeigt sich vermehrt, dass vor allem Transitkühe verstärkt an Stoffwechselerkrankungen in sowohl klinischer als auch subklinischer Form erkranken. Letztere stellen ein hohes Risiko dar, zum einen weil subklinische Erkrankungen oftmals nur schwer oder gar nicht erkannt werden und zum anderen, weil sie in vielen Fällen die Grundlage für meist schwerwiegendere Folgeerkrankungen sind. In der vorliegenden Studie wird das Thema der Früherkennung von subklinischen Ketosen und der subakuten Pansenazidose behandelt. Verschiedene Methoden wurden unter praktischen Versuchsbedingungen auf ihre Tauglichkeit zur Krankheitserkennung hin geprüft. In einer ersten Studie wurde auf einem konventionellen Milchviehbetrieb ein Ketose-Monitoring bei frischlaktierenden Kühen ab Tag 3 postpartum durchgeführt. Insgesamt 15 Tiere waren an einer subklinischen Ketose erkrankt, was eine Aufkommensrate von 26% in den untersuchten Tieren bedeutete. Die Blutproben von insgesamt 24 Tieren wurden auf ihren IL-6-Gehalt untersucht. Von den untersuchten Tieren waren 14 Tiere erkrankt, 10 Tiere bildeten die gesunde Kontrollgruppe. Interleukin-6 wurde bestimmt, da dem Zytokin IL-6 in anderen Studien in Bezug auf Ketosen eine Rolle zugesprochen wurde. Die erwartete Erhöhung von IL-6 bei erkrankten Tieren konnte nicht festgestellt werden; die erkrankten Kühe zeigten vielmehr die niedrigsten IL-6 Werte der Studiengruppe. Insgesamt waren die IL-6 Konzentrationen auf einem niedrigen Niveau mit 27.2 pg/m l± 10.2. Es zeigte sich, dass die IL-6 Bestimmung im Blut hinsichtlich der Erkennung von subklinischen Ketosen nur eingeschränkt nutzbar ist. Es konnte ausschließlich eine schwache negative Korrelation zwischen Beta- Hydroxybutyrat (BHBA, Goldstandard für den Nachweis einer Ketose) und IL-6 detektiert werden. Zusätzlich zu den Blutanalysen wurde ebenfalls die tägliche Wiederkauaktivität mit dem „DairyCheck“ System bestimmt, welches kontinuierlich die charakteristischen Kaumuskelkontraktionen aufzeichnet und somit die Dauer des Wiederkäuens bestimmt werden kann. Es wurde geprüft, ob sich ketotische Tiere von nicht ketotischen Tieren hinsichtlich der täglichen Wiederkäuzeit unterscheiden. Milchkühe mit einer Ketose kauten im Schnitt 475 min/d ± 56 wieder, nach Genesung 497 min/d ± 48. Sie befanden sich somit im Durchschnitt immer unterhalb der gesunden Kontrollgruppe, welche 521 min/d ± 76 wiederkaute. Eine Korrelation zwischen der Wiederkauzeit und dem BHBA- Gehalt im Blut war nur sehr schwach ausgeprägt, nicht zuletzt da die Tiere generell eine hohe Variabilität in der Wiederkauaktivität zeigten. Bei einer weiteren Studie, ebenfalls auf einem Praxisbetrieb durchgeführt, wurde auf die Erkennung der subakuten Pansensazidose (SARA) fokussiert. Hierbei kam ein drahtloses, kommerziell verfügbares Bolussystem zum Einsatz, welches den pH Wert kontinuierlich im Retikulorumen misst. Es macht die Erkennung einer SARA auch unter Praxisbedingungen ohne invasive Methoden wie der Punktion möglich. Das Bolussystem wurde 24 Milchkühen kurz vor der Abkalbung oral eingegeben, um den pH-Wert während der gesamten Transitphase messen und überwachen zu können. Während in der Trockenstehphase nur vereinzelte SARA Fälle auftraten, erlitt ein Großteil der untersuchten Tiere in der Frühlaktation eine SARA. Auf Grundlage von pH-Werten von laktierenden Milchkühen, wurde zusätzlich eine Sensitivitätsanalyse von verschieden, bereits eingesetzten Nachweismethoden durchgeführt, um die Tauglichkeit für die SARA-Diagnostik zu untersuchen. Es handelte sich hierbei zum einen um einen SARA-Nachweis unter Heranziehung von Einzelwerten, Fress- und Wiederkäuzeiten, sowie ausgewählten Milchinhaltsstoffen und der Milchmenge. Die Analyse ergab, dass nahezu alle Nachweismethoden im Vergleich zur Langzeitmessung nur eingeschränkt zur SARA-Diagnostik nutzbar sind. In einem weiteren Teil der Studie wurde eine Kotfraktionierung bei den gleichen Tieren durchgeführt, um damit SARA-Tiere auch mittels der Kotanalyse erkennen kann. Es konnte gezeigt werden, dass zum einen die Ration einen Einfluss auf die Kotzusammensetzung hat (Trockensteherration versus Ration für Laktierende) zum anderen aber auch, dass eine SARA die Zusammensetzung des Kotes verändert. Hierfür wurden Kotproben ausschließlich von laktierenden Kühen untersucht, sodass der Einfluss der Ration ausgeschlossen werden konnte. Erhöhte Faseranteile im Kot von SARA - Kühen gaben Hinweis auf eine verminderte Verdaulichkeit. Dabei erwies sich vor allem die Hemizellulose als guter Parameter, um auf eine SARA schließen zu können. Die Versuchsbedingungen ließen es ebenfalls zu, die pH-Verläufe der Tiere in der Frühlaktation zu untersuchen. Eine Clusteranalyse von pH-Werten der ersten 12 Tage postpartum zeigte, dass die untersuchten Tiere trotz gleicher Haltungs- und Fütterungsbedingungen unterschiedliche pH-Wert Verläufe entwickelten. So gab es eine Gruppe von Milchkühen, die den pH-Wert stabil halten konnte, während die restlichen pH-Abfälle in verschiedenen Verläufen und Intensitäten aufzeigten. Es konnte ebenfalls aufgezeigt werden, dass Tiere innerhalb der Testherde unterschiedliche Schweregrade der SARA entwickelten. Auch in dieser Studie wurde deutlich, dass Tiere scheinbar unterschiedliche Möglichkeiten haben, auf ihre Umwelt zu reagieren, bzw. suboptimalen Bedingungen entgegenwirken zu können. Zusammengefasst wurden verschiedene Methoden zur Ketose- und SARA- Erkennung geprüft, von denen nur einzelne für die Praxis zu empfehlen sind. Die Variabilität der Tiere, sowohl bei der Ausprägung der Erkrankungen als auch bei den gemessenen Parametern verdeutlicht die Notwendigkeit, diese im Herden- und Gesundheitsmanagement in Zukunft stärker zu berücksichtigen.