8 resultados para Vector sensor
em Universitätsbibliothek Kassel, Universität Kassel, Germany
Resumo:
At present, a fraction of 0.1 - 0.2% of the patients undergoing surgery become aware during the process. The situation is referred to as anesthesia awareness and is obviously very traumatic for the person experiencing it. The reason for its occurrence is mostly an insufficient dosage of the narcotic Propofol combined with the incapability of the technology monitoring the depth of the patient’s anesthetic state to notice the patient becoming aware. A solution can be a highly sensitive and selective real time monitoring device for Propofol based on optical absorption spectroscopy. Its working principle has been postulated by Prof. Dr. habil. H. Hillmer and formulated in DE10 2004 037 519 B4, filed on Aug 30th, 2004. It consists of the exploitation of Intra Cavity Absorption effects in a two mode laser system. In this Dissertation, a two mode external cavity semiconductor laser, which has been developed previously to this work is enhanced and optimized to a functional sensor. Enhancements include the implementation of variable couplers into the system and the implementation of a collimator arrangement into which samples can be introduced. A sample holder and cells are developed and characterized with a focus on compatibility with the measurement approach. Further optimization concerns the overall performance of the system: scattering sources are reduced by re-splicing all fiber-to-fiber connections, parasitic cavities are eliminated by suppressing the Fresnel reflexes of all one fiber ends by means of optical isolators and wavelength stability of the system is improved by the implementation of thermal insulation to the Fiber Bragg Gratings (FBG). The final laser sensor is characterized in detail thermally and optically. Two separate modes are obtained at 1542.0 and 1542.5 nm, tunable in a range of 1nm each. Mode Full Width at Half Maximum (FWHM) is 0.06nm and Signal to Noise Ratio (SNR) is as high as 55 dB. Independent of tuning the two modes of the system can always be equalized in intensity, which is important as the delicacy of the intensity equilibrium is one of the main sensitivity enhancing effects formulated in DE10 2004 037 519 B4. For the proof of concept (POC) measurements the target substance Propofol is diluted in the solvents Acetone and DiChloroMethane (DCM), which have been investigated for compatibility with Propofol beforehand. Eight measurement series (two solvents, two cell lengths and two different mode spacings) are taken, which draw a uniform picture: mode intensity ratio responds linearly to an increase of Propofol in all cases. The slope of the linear response indicates the sensitivity of the system. The eight series are split up into two groups: measurements taken in long cells and measurements taken in short cells.
Resumo:
This thesis concerns with the main aspects of medical trace molecules detection by means of intracavity laser absorption spectroscopy (ICLAS), namely with the equirements for highly sensitive, highly selective, low price, and compact size sensor. A novel two modes semiconductor laser sensor is demonstrated. Its operation principle is based on the competition between these two modes. The sensor sensitivity is improved when the sample is placed inside the two modes laser cavity, and the competition between the two modes exists. The effects of the mode competition in ICLAS are discussed theoretically and experimentally. The sensor selectivity is enhanced using external cavity diode laser (ECDL) configuration, where the tuning range only depends on the external cavity configuration. In order to considerably reduce the sensor cost, relative intensity noise (RIN) is chosen for monitoring the intensity ratio of the two modes. RIN is found to be an excellent indicator for the two modes intensity ratio variations which strongly supports the sensor methodology. On the other hand, it has been found that, wavelength tuning has no effect on the RIN spectrum which is very beneficial for the proposed detection principle. In order to use the sensor for medical applications, the absorption line of an anesthetic sample, propofol, is measured. Propofol has been dissolved in various solvents. RIN has been chosen to monitor the sensor response. From the measured spectra, the sensor sensitivity enhancement factor is found to be of the order of 10^(3) times of the conventional laser spectroscopy.
Resumo:
ZUSAMMENFASSUNG: Proteinkinasen übernehmen zentrale Aufgaben in der Signaltransduktion höherer Zellen. Dabei ist die cAMP-abhängige Proteinkinase (PKA) bezüglich ihrer Struktur und Funktion eine der am besten charakterisierten Proteinkinasen. Trotzdem ist wenig über direkte Interaktionspartner der katalytischen Untereinheiten (PKA-C) bekannt. In einem Split-Ubiquitin basiertem Yeast Two Hybrid- (Y2H-)System wurden potenzielle Interaktionspartner der PKA-C identifiziert. Als Bait wurden sowohl die humane Hauptisoform Cα (hCα) als auch die Proteinkinase X (PrKX) eingesetzt. Nach der Bestätigung der Funktionalität der PKA-C-Baitproteine, dem Nachweis der Expression und der Interaktion mit dem bekannten Interaktionspartner PKI wurde ein Y2H-Screen gegen eine Mausembryo-cDNA-Expressionsbibliothek durchgeführt. Von 2*10^6 Klonen wurden 76 Kolonien isoliert, die ein mit PrKX interagierendes Preyprotein exprimierten. Über die Sequenzierung der enthaltenen Prey-Vektoren wurden 25 unterschiedliche, potenzielle Interaktionspartner identifiziert. Für hCα wurden über 2*10^6 S. cerevisiae-Kolonien untersucht, von denen 1.959 positiv waren (1.663 unter erhöhter Stringenz). Über die Sequenzierung von ca. 10% der Klone (168) konnten Sequenzen für 67 verschiedene, potenzielle Interaktionspartner der hCα identifiziert werden. 15 der Preyproteine wurden in beiden Screens identifiziert. Die PKA-C-spezifische Wechselwirkung der insgesamt 77 Preyproteine wurde im Bait Dependency Test gegen largeT, ein Protein ohne Bezug zum PKA-System, untersucht. Aus den PKA-C-spezifischen Bindern wurden die löslichen Preyproteine AMY-1, Bax72-192, Fabp3, Gng11, MiF, Nm23-M1, Nm23-M2, Sssca1 und VASP256-375 für die weitere in vitro-Validierung ausgewählt. Die Interaktion von FLAG-Strep-Strep-hCα (FSS-hCα) mit den über Strep-Tactin aus der rekombinanten Expression in E. coli gereinigten One-STrEP-HA-Proteinen (SSHA-Proteine) wurde über Koimmunpräzipitation für SSHA-Fabp3, -Nm23-M1, -Nm23-M2, -Sssca1 und -VASP256-375 bestätigt. In SPR-Untersuchungen, für die hCα kovalent an die Oberfläche eines CM5-Sensorchips gekoppelt wurde, wurden die ATP/Mg2+-Abhängigkeit der Bindungen sowie differentielle Effekte der ATP-kompetitiven Inhibitoren H89 und HA-1077 untersucht. Freie hCα, die vor der Injektion zu den SSHA-Proteinen gegeben wurde, kompetierte im Gegensatz zu FSS-PrKX die Bindung an die hCα-Oberfläche. Erste kinetische Analysen lieferten Gleichgewichtsdissoziationskonstanten im µM- (SSHA-Fabp3, -Sssca1), nM- (SSHA-Nm23-M1, –M2) bzw. pM- (SSHA-VASP256-375) Bereich. In funktionellen Analysen konnte eine Phosphorylierung von SSHA-Sssca1 und VASP256-375 durch hCα und FSS-PrKX im Autoradiogramm nachgewiesen werden. SSHA-VASP256-375 zeigte zudem eine starke Inhibition von hCα im Mobility Shift-Assay. Dieser inhibitorische Effekt sowie die hohe Affinität konnten jedoch auf eine Kombination aus der Linkersequenz des Vektors und dem N-Terminus von VASP256-375 zurückgeführt werden. Über die Wechselwirkungen der hier identifizierten Interaktionspartner Fabp3, Nm23-M1 und Nm23-M2 mit hCα können in Folgeuntersuchungen neue PKA-Funktionen insbesondere im Herzen sowie während der Zellmigration aufgedeckt werden. Sssca1 stellt dagegen ein neues, näher zu charakterisierendes PKA-Substrat dar.
Resumo:
Die thermische Verarbeitung von Lebensmitteln beeinflusst deren Qualität und ernährungsphysiologischen Eigenschaften. Im Haushalt ist die Überwachung der Temperatur innerhalb des Lebensmittels sehr schwierig. Zudem ist das Wissen über optimale Temperatur- und Zeitparameter für die verschiedenen Speisen oft unzureichend. Die optimale Steuerung der thermischen Zubereitung ist maßgeblich abhängig von der Art des Lebensmittels und der äußeren und inneren Temperatureinwirkung während des Garvorgangs. Das Ziel der Arbeiten war die Entwicklung eines automatischen Backofens, der in der Lage ist, die Art des Lebensmittels zu erkennen und die Temperatur im Inneren des Lebensmittels während des Backens zu errechnen. Die für die Temperaturberechnung benötigten Daten wurden mit mehreren Sensoren erfasst. Hierzu kam ein Infrarotthermometer, ein Infrarotabstandssensor, eine Kamera, ein Temperatursensor und ein Lambdasonde innerhalb des Ofens zum Einsatz. Ferner wurden eine Wägezelle, ein Strom- sowie Spannungs-Sensor und ein Temperatursensor außerhalb des Ofens genutzt. Die während der Aufheizphase aufgenommen Datensätze ermöglichten das Training mehrerer künstlicher neuronaler Netze, die die verschiedenen Lebensmittel in die entsprechenden Kategorien einordnen konnten, um so das optimale Backprogram auszuwählen. Zur Abschätzung der thermische Diffusivität der Nahrung, die von der Zusammensetzung (Kohlenhydrate, Fett, Protein, Wasser) abhängt, wurden mehrere künstliche neuronale Netze trainiert. Mit Ausnahme des Fettanteils der Lebensmittel konnten alle Komponenten durch verschiedene KNNs mit einem Maximum von 8 versteckten Neuronen ausreichend genau abgeschätzt werden um auf deren Grundlage die Temperatur im inneren des Lebensmittels zu berechnen. Die durchgeführte Arbeit zeigt, dass mit Hilfe verschiedenster Sensoren zur direkten beziehungsweise indirekten Messung der äußeren Eigenschaften der Lebensmittel sowie KNNs für die Kategorisierung und Abschätzung der Lebensmittelzusammensetzung die automatische Erkennung und Berechnung der inneren Temperatur von verschiedensten Lebensmitteln möglich ist.
Resumo:
The measurement of feed intake, feeding time and rumination time, summarized by the term feeding behavior, are helpful indicators for early recognition of animals which show deviations in their behavior. The overall objective of this work was the development of an early warning system for inadequate feeding rations and digestive and metabolic disorders, which prevention constitutes the basis for health, performance, and reproduction. In a literature review, the current state of the art and the suitability of different measurement tools to determine feeding behavior of ruminants was discussed. Five measurement methods based on different methodological approaches (visual observance, pressure transducer, electrical switches, electrical deformation sensors and acoustic biotelemetry), and three selected measurement techniques (the IGER Behavior Recorder, the Hi-Tag rumination monitoring system and RumiWatchSystem) were described, assessed and compared to each other within this review. In the second study, the new system for measuring feeding behavior of dairy cows was evaluated. The measurement of feeding behavior ensues through electromyography (EMG). For validation, the feeding behavior of 14 cows was determined by both the EMG system and by visual observation. The high correlation coefficients indicate that the current system is a reliable and suitable tool for monitoring the feeding behavior of dairy cows. The aim of a further study was to compare the DairyCheck (DC) system and two additional measurement systems for measuring rumination behavior in relation to efficiency, reliability and reproducibility, with respect to each other. The two additional systems were labeled as the Lely Qwes HR (HR) sensor, and the RumiWatchSystem (RW). Results of accordance of RW and DC to each other were high. The last study examined whether rumination time (RT) is affected by the onset of calving and if it might be a useful indicator for the prediction of imminent birth. Data analysis referred to the final 72h before the onset of calving, which were divided into twelve 6h-blocks. The results showed that RT was significantly reduced in the final 6h before imminent birth.
Resumo:
Tunable Optical Sensor Arrays (TOSA) based on Fabry-Pérot (FP) filters, for high quality spectroscopic applications in the visible and near infrared spectral range are investigated within this work. The optical performance of the FP filters is improved by using ion beam sputtered niobium pentoxide (Nb2O5) and silicon dioxide (SiO2) Distributed Bragg Reflectors (DBRs) as mirrors. Due to their high refractive index contrast, only a few alternating pairs of Nb2O5 and SiO2 films can achieve DBRs with high reflectivity in a wide spectral range, while ion beam sputter deposition (IBSD) is utilized due to its ability to produce films with high optical purity. However, IBSD films are highly stressed; resulting in stress induced mirror curvature and suspension bending in the free standing filter suspensions of the MEMS (Micro-Electro-Mechanical Systems) FP filters. Stress induced mirror curvature results in filter transmission line degradation, while suspension bending results in high required filter tuning voltages. Moreover, stress induced suspension bending results in higher order mode filter operation which in turn degrades the optical resolution of the filter. Therefore, the deposition process is optimized to achieve both near zero absorption and low residual stress. High energy ion bombardment during film deposition is utilized to reduce the film density, and hence the film compressive stress. Utilizing this technique, the compressive stress of Nb2O5 is reduced by ~43%, while that for SiO2 is reduced by ~40%. Filters fabricated with stress reduced films show curvatures as low as 100 nm for 70 μm mirrors. To reduce the stress induced bending in the free standing filter suspensions, a stress optimized multi-layer suspension design is presented; with a tensile stressed metal sandwiched between two compressively stressed films. The stress in Physical Vapor Deposited (PVD) metals is therefore characterized for use as filter top-electrode and stress compensating layer. Surface micromachining is used to fabricate tunable FP filters in the visible spectral range using the above mentioned design. The upward bending of the suspensions is reduced from several micrometers to less than 100 nm and 250 nm for two different suspension layer combinations. Mechanical tuning of up to 188 nm is obtained by applying 40 V of actuation voltage. Alternatively, a filter line with transmission of 65.5%, Full Width at Half Maximum (FWHM) of 10.5 nm and a stopband of 170 nm (at an output wavelength of 594 nm) is achieved. Numerical model simulations are also performed to study the validity of the stress optimized suspension design for the near infrared spectral range, wherein membrane displacement and suspension deformation due to material residual stress is studied. Two bandpass filter designs based on quarter-wave and non-quarter-wave layers are presented as integral components of the TOSA. With a filter passband of 135 nm and a broad stopband of over 650 nm, high average filter transmission of 88% is achieved inside the passband, while maximum filter transmission of less than 1.6% outside the passband is achieved.
Resumo:
Punktförmig messende optische Sensoren zum Erfassen von Oberflächentopografien im Nanometerbereich werden in der Forschung und Industrie benötigt. Dennoch ist die Auswahl unterschiedlicher Technologien und kommerziell verfügbarer Sensoren gering. In dieser Dissertationsschrift werden die wesentlichen Aspekte eines Messsystems untersucht das über das Potenzial verfügt, zu den künftigen Standardmessmethoden zu gehören. Das Messprinzip beruht auf einem Common-Path-Interferometer. In einer mikrooptischen Sonde wird das Laserlicht auf die zu untersuchende Oberfläche gerichtet. Das vom Messobjekt reflektierte Licht interferiert sondenintern mit einem Referenzreflex. Die kompakte Bauweise bewirkt kurze optische Wege und eine gewisse Robustheit gegen Störeinflüsse. Die Abstandsinformation wird durch eine mechanische Oszillation in eine Phasenmodulation überführt. Die Phasenmodulation ermöglicht eine robuste Auswertung des Interferenzsignals, auch wenn eine zusätzliche Amplitudenmodulation vorhanden ist. Dies bietet den Vorteil, unterschiedlich geartete Oberflächen messen zu können, z. B. raue, teilweise transparente und geneigte Oberflächen. Es können wiederholbar Messungen mit einer Standardabweichung unter einem Nanometer erzielt werden. Die beschriebene mechanische Oszillation wird durch ein periodisches elektrisches Signal an einem piezoelektrischen Aktor hervorgerufen, der in einem Biegebalken integriert ist. Die Bauform des Balkens gestattet eine Hybridisierung von optischen und mechanischen Komponenten zu einer Einheit, welche den Weg zur weiteren Miniaturisierung aufzeigt. Im Rahmen dieser Arbeit konnte so u. a. eine Sonde mit einer Bauhöhe unter 10 mm gefertigt werden. Durch eine zweite optische Wellenlänge lässt sich der eingeschränkte Eindeutigkeitsbereich des Laserinterferometers nachweislich vergrößern. Die hierfür eingesetzte Methode, die Stand der Technik ist, konnte erfolgreich problemspezifisch angepasst werden. Um das volle Potenzial des Sensors nutzen zu können, wurden zudem zahlreiche Algorithmen entworfen und erfolgreich getestet. Anhand von hier dokumentierten Messergebnissen können die Möglichkeiten, als auch die Schwächen des Messsystems abgeschätzt werden.
Resumo:
Im Rahmen dieser Arbeit wird eine gemeinsame Optimierung der Hybrid-Betriebsstrategie und des Verhaltens des Verbrennungsmotors vorgestellt. Die Übernahme von den im Steuergerät verwendeten Funktionsmodulen in die Simulationsumgebung für Fahrzeuglängsdynamik stellt eine effiziente Applikationsmöglichkeit der Originalparametrierung dar. Gleichzeitig ist es notwendig, das Verhalten des Verbrennungsmotors derart nachzubilden, dass das stationäre und das dynamische Verhalten, inklusive aller relevanten Einflussmöglichkeiten, wiedergegeben werden kann. Das entwickelte Werkzeug zur Übertragung der in Ascet definierten Steurgerätefunktionen in die Simulink-Simulationsumgebung ermöglicht nicht nur die Simulation der relevanten Funktionsmodule, sondern es erfüllt auch weitere wichtige Eigenschaften. Eine erhöhte Flexibilität bezüglich der Daten- und Funktionsstandänderungen, sowie die Parametrierbarkeit der Funktionsmodule sind Verbesserungen die an dieser Stelle zu nennen sind. Bei der Modellierung des stationären Systemverhaltens des Verbrennungsmotors erfolgt der Einsatz von künstlichen neuronalen Netzen. Die Auswahl der optimalen Neuronenanzahl erfolgt durch die Betrachtung des SSE für die Trainings- und die Verifikationsdaten. Falls notwendig, wird zur Sicherstellung der angestrebten Modellqualität, das Interpolationsverhalten durch Hinzunahme von Gauß-Prozess-Modellen verbessert. Mit den Gauß-Prozess-Modellen werden hierbei zusätzliche Stützpunkte erzeugt und mit einer verminderten Priorität in die Modellierung eingebunden. Für die Modellierung des dynamischen Systemverhaltens werden lineare Übertragungsfunktionen verwendet. Bei der Minimierung der Abweichung zwischen dem Modellausgang und den Messergebnissen wird zusätzlich zum SSE das 2σ-Intervall der relativen Fehlerverteilung betrachtet. Die Implementierung der Steuergerätefunktionsmodule und der erstellten Steller-Sensor-Streckenmodelle in der Simulationsumgebung für Fahrzeuglängsdynamik führt zum Anstieg der Simulationszeit und einer Vergrößerung des Parameterraums. Das aus Regelungstechnik bekannte Verfahren der Gütevektoroptimierung trägt entscheidend zu einer systematischen Betrachtung und Optimierung der Zielgrößen bei. Das Ergebnis des Verfahrens ist durch das Optimum der Paretofront der einzelnen Entwurfsspezifikationen gekennzeichnet. Die steigenden Simulationszeiten benachteiligen Minimumsuchverfahren, die eine Vielzahl an Iterationen benötigen. Um die Verwendung einer Zufallsvariablen, die maßgeblich zur Steigerung der Iterationanzahl beiträgt, zu vermeiden und gleichzeitig eine Globalisierung der Suche im Parameterraum zu ermöglichen wird die entwickelte Methode DelaunaySearch eingesetzt. Im Gegensatz zu den bekannten Algorithmen, wie die Partikelschwarmoptimierung oder die evolutionären Algorithmen, setzt die neu entwickelte Methode bei der Suche nach dem Minimum einer Kostenfunktion auf eine systematische Analyse der durchgeführten Simulationsergebnisse. Mit Hilfe der bei der Analyse gewonnenen Informationen werden Bereiche mit den bestmöglichen Voraussetzungen für ein Minimum identifiziert. Somit verzichtet das iterative Verfahren bei der Bestimmung des nächsten Iterationsschrittes auf die Verwendung einer Zufallsvariable. Als Ergebnis der Berechnungen steht ein gut gewählter Startwert für eine lokale Optimierung zur Verfügung. Aufbauend auf der Simulation der Fahrzeuglängsdynamik, der Steuergerätefunktionen und der Steller-Sensor-Streckenmodelle in einer Simulationsumgebung wird die Hybrid-Betriebsstrategie gemeinsam mit der Steuerung des Verbrennungsmotors optimiert. Mit der Entwicklung und Implementierung einer neuen Funktion wird weiterhin die Verbindung zwischen der Betriebsstrategie und der Motorsteuerung erweitert. Die vorgestellten Werkzeuge ermöglichten hierbei nicht nur einen Test der neuen Funktionalitäten, sondern auch eine Abschätzung der Verbesserungspotentiale beim Verbrauch und Abgasemissionen. Insgesamt konnte eine effiziente Testumgebung für eine gemeinsame Optimierung der Betriebsstrategie und des Verbrennungsmotorverhaltens eines Hybridfahrzeugs realisiert werden.