4 resultados para Surface Enhanced Raman Spectroscopy

em Universitätsbibliothek Kassel, Universität Kassel, Germany


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work deals with the optical properties of supported noble metal nanoparticles, which are dominated by the so-called Mie resonance and are strongly dependent on the particles’ morphology. For this reason, characterization and control of the dimension of these systems are desired in order to optimize their applications. Gold and silver nanoparticles have been produced on dielectric supports like quartz glass, sapphire and rutile, by the technique of vapor deposition under ultra-high vacuum conditions. During the preparation, coalescence is observed as an important mechanism of cluster growth. The particles have been studied in situ by optical transmission spectroscopy and ex situ by atomic force microscopy. It is shown that the morphology of the aggregates can be regarded as oblate spheroids. A theoretical treatment of their optical properties, based on the quasistatic approximation, and its combination with results obtained by atomic force microscopy give a detailed characterization of the nanoparticles. This method has been compared with transmission electron microscopy and the results are in excellent agreement. Tailoring of the clusters’ dimensions by irradiation with nanosecond-pulsed laser light has been investigated. Selected particles are heated within the ensemble by excitation of the Mie resonance under irradiation with a tunable laser source. Laser-induced coalescence prevents strongly tailoring of the particle size. Nevertheless, control of the particle shape is possible. Laser-tailored ensembles have been tested as substrates for surface-enhanced Raman spectroscopy (SERS), leading to an improvement of the results. Moreover, they constitute reproducible, robust and tunable SERS-substrates with a high potential for specific applications, in the present case focused on environmental protection. Thereby, these SERS-substrates are ideally suited for routine measurements.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work presents the developement of an chemically stable and easy to produce in situ sensor for fast and reliable detection of polycyclic aromatic hydrocarbons (PAH) in low nanomolar concentrations. Metallic nanoparticles on dielectric substrates werde used for the rst time with surface enhanced Raman spectroscopy (SERS) in combination with shifted excitation Raman difference spectroscopy (SERDS). The preparation of the metallic nanoparticle ensembles with Volmer-Webergrowth is described first. The nanoparticles are characterized with both, optical spectroscopy and atomic force microscopy. The morphological properties of the nanoparticle ensembles are de ned by the mean axial ratio (a/b) and the mean equivalent radius (R Äq), respectively. The prepared and characterized nanoparticles were then used for intensive Raman spectroscopy measurements. Two sophisticated diode laser systems were used in cooperation with the TU Berlin, to carry out these experiments. The first step was to establish the ideal combination of excitation wavelength of the diode laser and the maximum of the surface plasmon resonance of the nanoparticle ensembles. From these results it was deduced, that for an optimum Raman signal the plasmon resonance maximum of the nanoparticle ensemble has to be red-shifted a few nanometeres in respect to the excitation wavelength. Different PAHs werde detected in concentrations of only 2 and 0.5 nmol/, respectively. Furthermore, the obtained results show an excellent reproducability. In addition the time dependence of the Raman signal intensity was investigated. The results of these measurements show, that only 2 minutes after placing the substrates in the molecular solution, a detectable Raman signal was generated. The maximum Raman signal, i.e. the time in which the molecular adsorption process is finished, was determined to about 10 minutes. In summary it was shown, that the used metallic nanoparticle ensembles are highly usable as substrates for SERS in combination with SERDS to detect PAHs in low nanomolar concentrations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Boron-doped diamond is a promising electrode material for a number of applications providing efficient carrier transport, a high stability of the electrolytic performance with time, a possibility for dye-sensitizing with photosensitive molecules, etc. It can be functionalized with electron donor molecules, like phthalocyanines or porphyrins, for the development of light energy conversion systems. For effective attachment of such molecules, the diamond surface has to be modified by plasma- or photo-chemical processes in order to achieve a desired surface termination. In the present work, the surface modifications of undoped and boron-doped nanocrystalline diamond (NCD) films and their functionalization with various phthalocyanines (Pcs) were investigated. The NCD films have been prepared by hot filament chemical vapor deposition (HFCVD) on silicon substrates and were thereafter subjected to modifications with O2 or NH3 plasmas or UV/O3 treatments for exchange of the H-termination of the as-grown surface. The effectiveness of the modifications and their stability with time during storage under different ambients were studied by contact angle measurements and X-ray photoelectron spectroscopy (XPS). Furthermore, the surface roughness after the modifications was investigated with atomic force microscopy (AFM) and compared to that of as-grown samples in order to establish the appearance of etching of the surface during the treatment. The as-grown and the modified NCD surfaces were exposed to phthalocyanines with different metal centers (Ti, Cu, Mn) or with different side chains. The results of the Pc grafting were investigated by XPS and Raman spectroscopy. XPS revealed the presence of nitrogen stemming from the Pc molecules and traces of the respective metal atoms with ratios close to those in the applied Pc. In a next step Raman spectra of Ti-Pc, Cu-Pc and Mn-Pc were obtained with two different excitation wavelengths (488 and 785 nm) from droplet samples on Si after evaporation of the solvent in order to establish their Raman fingerprints. The major differences in the spectra were assigned to the effect of the size of the metal ion on the structure of the phthalocyanine ring. The spectra obtained were used as references for the Raman spectra of NCD surfaces grafted with Pc. Finally, selected boron doped NCD samples were used after their surface modification and functionalization with Pc for the preparation of electrodes which were tested in a photoelectrochemical cell with a Pt counter electrode and an Ag/AgCl reference electrode. The light sources and electrolytes were varied to establish their influence on the performance of the dye-sensitized diamond electrodes. Cyclic voltammetry measurements revealed broad electrochemical potential window and high stability of the electrodes after several cycles. The open circuit potential (OCP) measurements performed in dark and after illumination showed fast responses of the electrodes to the illumination resulting in photocurrent generation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mit dieser Arbeit wurde die Selbstassemblierung von dia- und paramagnetischen Molekülen sowie Einzelmolekülmagneten auf Goldsubstraten und magnetisch strukturierten Substraten untersucht. Dazu wurden drei verschiedene Klassen an Phthalocyaninderivaten verwendet: Diamagnetische Subphthalocyanine, paramagnetische Phthalocyaninatometalle und Diphthalocyaninatolanthanidkomplexe. Alle synthetisierten Verbindungen sind peripher thioethersubstituiert. Die Alkylketten (a: n-C8H17, b: n-C12H25) vermitteln die Löslichkeit in vielen organischen Solventien und sorgen für eine geordnete Assemblierung auf einer Oberfläche, wobei die Bindung auf Gold hauptsächlich über die Schwefelatome stattfindet. Die aus Lösung abgeschiedenen selbstassemblierten Monolagen wurden mit XPS, NEXAFS-Spektroskopie und ToF-SIMS untersucht. Bei der Selbstassemblierung auf magnetisch strukturierten Substraten stehen die Moleküle unter dem Einfluss magnetischer Streufelder und binden bevorzugt nur in bestimmten Bereichen. Die gebildeten Submonolagen wurden zusätzlich mit X-PEEM untersucht. Die erstmals dargestellten Manganphthalocyanine [MnClPc(SR)8] 1 wurden ausgehend von MnCl2 erhalten. Hier fand bei der Aufarbeitung an Luft eine Oxidation zu Mangan(III) statt; +III ist die stabilste Oxidationsstufe von Mangan in Phthalocyaninen. Der Nachweis des axialen Chloridoliganden erfolgte mit Massenspektrometrie und FIR- sowie Raman-Spektroskopie. SQUID-Messungen haben gezeigt, dass die Komplexe 1 vier ungepaarte Elektronen haben. Bei den Subphthalocyaninen [BClSubpc(SR)6] 2 wurde der axiale Chloridoligand mit dem stäbchenförmigen Phenolderivat 29-H substituiert und die erfolgreiche Ligandensubstitution durch NMR- und IR-Spektroskopie sowie Massenspektrometrie an den Produkten [BSubpc(SR)6(29)] 30 belegt. Der Radikalcharakter der synthetisierten Terbiumkomplexe [Tb{Pc(SR)8}2] 3 wurde spektroskopisch nachgewiesen; SQUID-Messungen ergaben, dass es sich um Einzelmolekülmagnete mit einer Energiebarriere U des Doppelpotentialtopfs von 880 K oder 610 cm-1 bei 3a handelt. Zunächst wurden die SAMs der Komplexverbindungen 1, 2, 30 und 3 auf nicht magnetisch strukturierten Goldsubstraten untersucht. Die Manganphthalocyanine 1 bilden geordnete SAMs mit größtenteils flach liegenden Molekülen, wie die XPS-, NEXAFS- und ToF-SIMS-Analyse zeigte. Die Mehrzahl der Thioether-Einheiten ist auf Gold koordiniert und die Alkylketten zeigen ungeordnet von der Oberfläche weg. Bei der Adsorption findet eine Reduktion zu Mangan(II) statt und der axiale Chloridoligand wird abgespalten. Das beruht auf dem sog. Oberflächen-trans-Effekt. Im vorliegenden Fall übt die Metalloberfläche einen stärkeren trans-Effekt als der axiale Ligand aus, was bisher experimentell noch nicht beobachtet wurde. Die thioethersubstituierten Subphthalocyanine 2 und 30 sowie die Diphthalocyaninatoterbium-Komplexe 3 sind ebenfalls für SAMs geeignet. Ihre Monolagen wurden mit XPS und NEXAFS-Spektroskopie untersucht, und trotz einer gewissen Unordnung in den Filmen liegen die Moleküle jeweils im Wesentlichen flach auf der Goldoberfläche. Vermutlich sind bei diesen Systemen auch die Alkylketten größtenteils parallel zur Oberfläche orientiert. Im Gegensatz zu den Manganphthalocyaninen 1 tritt bei 2b, 30a, 30b und 3b neben der koordinativen Bindung der Schwefelatome auf Gold auch eine für Thioether nicht erwartete kovalente Au–S-Bindung auf, die durch C–S-Bindungsbruch unter Abspaltung der Alkylketten ermöglicht wird. Der Anteil, zu dem dieser Prozess stattfindet, scheint nicht mit der Molekülstruktur zu korrelieren. Selbstassemblierte Submonolagen auf magnetisch strukturierten Substraten wurden mit dem diamagnetischen Subphthalocyanin 2b hergestellt. Der Nachweis der Submonolagen war schwierig und gelang schließlich durch eine Kombination von ToF-SIMS, NEXAFS Imaging und X-PEEM. Die Analyse der ToF-SIMS-Daten zeigte, dass tatsächlich eine Modulation der Verteilung der Moleküle auf einem unterwärts magnetisch strukturierten Substrat eintritt. Mit X-PEEM konnte die magnetische Struktur der ferromagnetischen Schicht des Substrats direkt der Verteilung der adsorbierten Moleküle zugeordnet werden. Die Subphthalocyanine 2b adsorbieren nicht an den Domänengrenzen, sondern vermehrt dazwischen. Auf Substraten mit abwechselnd 6.5 und 3.5 µm breiten magnetischen Domänen binden die Moleküle bevorzugt in den Bereichen geringster magnetischer Streufeldgradienten, also den größeren Domänen. Solche Substrate wurden für die ToF-SIMS- und X-PEEM-Messungen verwendet. Bei größeren magnetischen Strukturen mit ca. 400 µm breiten Domänen, wie sie aufgrund der geringeren Ortsauflösung dieser Methode für NEXAFS Imaging eingesetzt wurden, binden die Moleküle dann in allen Domänen. Die diamagnetischen Moleküle werden nach dieser Interpretation aus dem inhomogenen Magnetfeld über der Probenoberfläche heraus gedrängt und verhalten sich analog makroskopischer Diamagnete. Die eindeutige Detektion der Moleküle auf den magnetisch strukturierten Substraten konnte bisher nur für die diamagnetischen Subphthalocyanine 2b erfolgen. Um die Interpretation ihres Verhaltens bei der Selbstassemblierung in einem inhomogenen Magnetfeld weiter voranzutreiben, wurde das Subphthalocyanin 37b dargestellt, welches ein stabiles organisches TEMPO-Radikal in seinem axialen Liganden enthält. Das paramagnetische Subphthalocyanin 37b sollte auf den magnetisch strukturierten Substraten in Regionen starker magnetischer Streufelder binden und damit das entgegengesetzte Verhalten zu den diamagnetischen Subphthalocyaninen 2b zeigen. Aus Zeitgründen konnte dieser Nachweis im Rahmen dieser Arbeit noch nicht erbracht werden.