6 resultados para Signal spectrum

em Universitätsbibliothek Kassel, Universität Kassel, Germany


Relevância:

20.00% 20.00%

Publicador:

Resumo:

KLL-Auger transitions of the three electron system in Ne have been recorded in a coincidence experiment frec of contaminants from other systems. Energies as well as intensities are compared with calculated values.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a comparison between experimental and theoretical results for pump/probe multiphoton ionizing transitions of the sodium dimer, initiated by femtosecond laser pulses. It is shown that the motion of vibrational wavepackets in two electronic states is probed simultaneously and their dynamics is reflected in the total Na^+_2 ion signal which is recorded as a function of the time delay between pump and probe pulse. The time dependent quantum calculations demonstrate that two ionization pathways leading to the same final states of the molecularion exist: one gives an oscillating contribution to the ion signal, the other yields a constant background. From additional measurements of the Na^+ -transient photofragmentation spectrum it is deduced that another ionization process leading to different final ionic states exists. The process includes the excitation of a doubly excitedbound Rydberg state. This conclusion is supported by the theoretical simulation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The rapid growth in high data rate communication systems has introduced new high spectral efficient modulation techniques and standards such as LTE-A (long term evolution-advanced) for 4G (4th generation) systems. These techniques have provided a broader bandwidth but introduced high peak-to-average power ratio (PAR) problem at the high power amplifier (HPA) level of the communication system base transceiver station (BTS). To avoid spectral spreading due to high PAR, stringent requirement on linearity is needed which brings the HPA to operate at large back-off power at the expense of power efficiency. Consequently, high power devices are fundamental in HPAs for high linearity and efficiency. Recent development in wide bandgap power devices, in particular AlGaN/GaN HEMT, has offered higher power level with superior linearity-efficiency trade-off in microwaves communication. For cost-effective HPA design to production cycle, rigorous computer aided design (CAD) AlGaN/GaN HEMT models are essential to reflect real response with increasing power level and channel temperature. Therefore, large-size AlGaN/GaN HEMT large-signal electrothermal modeling procedure is proposed. The HEMT structure analysis, characterization, data processing, model extraction and model implementation phases have been covered in this thesis including trapping and self-heating dispersion accounting for nonlinear drain current collapse. The small-signal model is extracted using the 22-element modeling procedure developed in our department. The intrinsic large-signal model is deeply investigated in conjunction with linearity prediction. The accuracy of the nonlinear drain current has been enhanced through several issues such as trapping and self-heating characterization. Also, the HEMT structure thermal profile has been investigated and corresponding thermal resistance has been extracted through thermal simulation and chuck-controlled temperature pulsed I(V) and static DC measurements. Higher-order equivalent thermal model is extracted and implemented in the HEMT large-signal model to accurately estimate instantaneous channel temperature. Moreover, trapping and self-heating transients has been characterized through transient measurements. The obtained time constants are represented by equivalent sub-circuits and integrated in the nonlinear drain current implementation to account for complex communication signals dynamic prediction. The obtained verification of this table-based large-size large-signal electrothermal model implementation has illustrated high accuracy in terms of output power, gain, efficiency and nonlinearity prediction with respect to standard large-signal test signals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Neben der Verbreitung von gefährlichen Krankheiten sind Insekten für enorme agrarwirtschaftliche Schäden verantwortlich. Ein Großteil der Verhaltensweisen bei Insekten wird über den Geruchssinn gesteuert, der somit einen möglichen Angriffspunkt zur Bekämpfung von Schadinsekten darstellt. Hierzu ist es allerdings nötig, die Mechanismen der olfaktorischen Signalübertragung im Detail zu verstehen. Neben den duftstoffbindenden olfaktorischen Rezeptoren spielt hier auch ein konservierter Korezeptor (Orco) eine entscheidende Rolle. Inwieweit bei diesen Proteinen ionotrope bzw. metabotrope Prozesse involviert sind ist bislang nicht vollständig aufgeklärt. Um weitere Einzelheiten aufzuklären wurden daher Einzelsensillenableitungen am Tabakschwärmer Manduca sexta durchgeführt. Orco-Agonisten und Antagonisten wurden eingesetzt, um die Funktion des Korezeptors besser zu verstehen. Bei dem Einsatz des Orco-Agonisten VUAA1 konnte keine Verstärkung der Pheromonantworten bzw. eine Sensitivierung beobachtet werden, wie im Falle einer ionotropen Signalweiterleitung zu erwarten gewesen wäre. Ein ionotroper Signalweg über den OR/Orco-Komplex in M. sexta ist daher unwahrscheinlich. Der Orco-Antagonist OLC15 beeinflusste die gleichen Parameter wie VUAA1 und konnte die von VUAA1 generierte Spontanaktivität blocken. Daher ist es wahrscheinlich, dass dieser einen spezifischen Orco-Blocker darstellt. Sowohl VUAA1 als auch OLC15 hatten großen Effekt auf die langanhaltende Pheromonantwort, welches die Vermutung nahelegt, dass Orco modulierend auf die Sensitivität der Nervenzelle einwirkt. Von OLC15 abweichende Effekte durch die getesteten Amiloride HMA und MIA auf die Pheromonantwort lassen nicht auf eine spezifische Wirkung dieser Agenzien auf Orco schließen und zusätzliche Wirkorte sind anzunehmen. Um die These eines metabotropen Signalwegs zu überprüfen wurde ebenfalls der G-Protein-Blocker GDP-β-S eingesetzt. Alle Parameter der Pheromonantwort die innerhalb der ersten Millisekunden analysiert wurden wiesen eine Reduktion der Sensitivität auf. Im Gegensatz dazu hatte GDP-β-S keinen Effekt auf die langanhaltende Pheromonantwort. Somit scheint ausschließlich die schnelle Pheromonantwort über einen Ligand-bindenden G-Protein-gesteuerten Rezeptor gesteuert zu werden.