7 resultados para Operational efficiency

em Universitätsbibliothek Kassel, Universität Kassel, Germany


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A stand-alone power system is an autonomous system that supplies electricity to the user load without being connected to the electric grid. This kind of decentralized system is frequently located in remote and inaccessible areas. It is essential for about one third of the world population which are living in developed or isolated regions and have no access to an electricity utility grid. The most people live in remote and rural areas, with low population density, lacking even the basic infrastructure. The utility grid extension to these locations is not a cost effective option and sometimes technically not feasible. The purpose of this thesis is the modelling and simulation of a stand-alone hybrid power system, referred to as “hydrogen Photovoltaic-Fuel Cell (PVFC) hybrid system”. It couples a photovoltaic generator (PV), an alkaline water electrolyser, a storage gas tank, a proton exchange membrane fuel cell (PEMFC), and power conditioning units (PCU) to give different system topologies. The system is intended to be an environmentally friendly solution since it tries maximising the use of a renewable energy source. Electricity is produced by a PV generator to meet the requirements of a user load. Whenever there is enough solar radiation, the user load can be powered totally by the PV electricity. During periods of low solar radiation, auxiliary electricity is required. An alkaline high pressure water electrolyser is powered by the excess energy from the PV generator to produce hydrogen and oxygen at a pressure of maximum 30bar. Gases are stored without compression for short- (hourly or daily) and long- (seasonal) term. A proton exchange membrane (PEM) fuel cell is used to keep the system’s reliability at the same level as for the conventional system while decreasing the environmental impact of the whole system. The PEM fuel cell consumes gases which are produced by an electrolyser to meet the user load demand when the PV generator energy is deficient, so that it works as an auxiliary generator. Power conditioning units are appropriate for the conversion and dispatch the energy between the components of the system. No batteries are used in this system since they represent the weakest when used in PV systems due to their need for sophisticated control and their short lifetime. The model library, ISET Alternative Power Library (ISET-APL), is designed by the Institute of Solar Energy supply Technology (ISET) and used for the simulation of the hybrid system. The physical, analytical and/or empirical equations of each component are programmed and implemented separately in this library for the simulation software program Simplorer by C++ language. The model parameters are derived from manufacturer’s performance data sheets or measurements obtained from literature. The identification and validation of the major hydrogen PVFC hybrid system component models are evaluated according to the measured data of the components, from the manufacturer’s data sheet or from actual system operation. Then, the overall system is simulated, at intervals of one hour each, by using solar radiation as the primary energy input and hydrogen as energy storage for one year operation. A comparison between different topologies, such as DC or AC coupled systems, is carried out on the basis of energy point of view at two locations with different geographical latitudes, in Kassel/Germany (Europe) and in Cairo/Egypt (North Africa). The main conclusion in this work is that the simulation method of the system study under different conditions could successfully be used to give good visualization and comparison between those topologies for the overall performance of the system. The operational performance of the system is not only depending on component efficiency but also on system design and consumption behaviour. The worst case of this system is the low efficiency of the storage subsystem made of the electrolyser, the gas storage tank, and the fuel cell as it is around 25-34% at Cairo and 29-37% at Kassel. Therefore, the research for this system should be concentrated in the subsystem components development especially the fuel cell.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thermoaktive Bauteilsysteme sind Bauteile, die als Teil der Raumumschließungsflächen über ein integriertes Rohrsystem mit einem Heiz- oder Kühlmedium beaufschlagt werden können und so die Beheizung oder Kühlung des Raumes ermöglichen. Die Konstruktionenvielfalt reicht nach diesem Verständnis von Heiz, bzw. Kühldecken über Geschoßtrenndecken mit kern-integrierten Rohren bis hin zu den Fußbodenheizungen. Die darin enthaltenen extrem trägen Systeme werden bewußt eingesetzt, um Energieangebot und Raumenergiebedarf unter dem Aspekt der rationellen Energieanwendung zeitlich zu entkoppeln, z. B. aktive Bauteilkühlung in der Nacht, passive Raumkühlung über das kühle Bauteil am Tage. Gebäude- und Anlagenkonzepte, die träge reagierende thermoaktive Bauteilsysteme vorsehen, setzen im kompetenten und verantwortungsvollen Planungsprozeß den Einsatz moderner Gebäudesimulationswerkzeuge voraus, um fundierte Aussagen über Behaglichkeit und Energiebedarf treffen zu können. Die thermoaktiven Bauteilsysteme werden innerhalb dieser Werkzeuge durch Berechnungskomponenten repräsentiert, die auf mathematisch-physikalischen Modellen basieren und zur Lösung des bauteilimmanenten mehrdimensionalen instationären Wärmeleitungsproblems dienen. Bisher standen hierfür zwei unterschiedliche prinzipielle Vorgehensweisen zur Lösung zur Verfügung, die der physikalischen Modellbildung entstammen und Grenzen bzgl. abbildbarer Geometrie oder Rechengeschwindigkeit setzen. Die vorliegende Arbeit dokumentiert eine neue Herangehensweise, die als experimentelle Modellbildung bezeichnet wird. Über den Weg der Systemidentifikation können aus experimentell ermittelten Datenreihen die Parameter für ein kompaktes Black-Box-Modell bestimmt werden, das das Eingangs-Ausgangsverhalten des zugehörigen beliebig aufgebauten thermoaktiven Bauteils mit hinreichender Genauigkeit widergibt. Die Meßdatenreihen lassen sich über hochgenaue Berechnungen generieren, die auf Grund ihrer Detailtreue für den unmittelbaren Einsatz in der Gebäudesimulation ungeeignet wären. Die Anwendung der Systemidentifikation auf das zweidimensionale Wärmeleitungsproblem und der Nachweis ihrer Eignung wird an Hand von sechs sehr unterschiedlichen Aufbauten thermoaktiver Bauteilsysteme durchgeführt und bestätigt sehr geringe Temperatur- und Energiebilanzfehler. Vergleiche zwischen via Systemidentifikation ermittelten Black-Box-Modellen und physikalischen Modellen für zwei Fußbodenkonstruktionen zeigen, daß erstgenannte auch als Referenz für Genauigkeitsabschätzungen herangezogen werden können. Die Praktikabilität des neuen Modellierungsansatzes wird an Fallstudien demonstriert, die Ganzjahressimulationen unter Bauteil- und Betriebsvariationen an einem exemplarischen Büroraum betreffen. Dazu erfolgt die Integration des Black-Box-Modells in das kommerzielle Gebäude- und Anlagensimulationsprogramm CARNOT. Die akzeptablen Rechenzeiten für ein Einzonen-Gebäudemodell in Verbindung mit den hohen Genauigkeiten bescheinigen die Eignung der neuen Modellierungsweise.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Like elsewhere also in Kabul, Afghanistan urban and peri-urban agriculture (UPA) has often been accused of being resource inefficient and unsustainable causing negatives externalities to community health and to the surroundings. These arise from the inappropriate management and use of agricultural inputs, including often pesticides and inter-city wastes containing heavy metal residues and pathogens. To address these concerns, parallel studies with the aims of quantification of carbon (C), nitrogen (N), phosphorus (P) and potassium (K) horizontal and vertical fluxes; the assessment of heavy metal and pathogen contaminations of UPA produce, and an economic analysis of cereal, vegetable and grape production systems conducted for two years in UPA of Kabul from April 2008 to October 2009. The results of the studies from these three UPA diverse production systems can be abridged as follows: Biennial net balances in vegetable production systems were positive for N (80 kg ha-1 ), P (75 kg ha-1) and C (3,927 kg ha-1), negative for K (-205 kg ha-1), whereas in cereal production systems biennial horizontal balances were positive for P (20 kg ha-1 ) and C (4,900 kg ha-1) negative for N (-155 kg ha-1) and K (-355 kg ha-1) and in vineyards corresponding values were highly positive for N (295 kg ha-1), P (235 kg ha-1), C (3,362 kg ha-1) and slightly positive for K (5 kg ha-1). Regardless of N and C gaseous emissions, yearly leaching losses of N and P in selected vegetable gardens varied from 70 - 205 kg N ha-1 and 5 - 10 kg P ha-1. Manure and irrigation water contributed on average 12 - 79% to total Inputs of N, P, K and C, 10 - 53% to total inputs of C in the gardens and fields. The elevated levels of heavy metal and pathogen loads on fresh UPA vegetables reflected contamination from increasing traffic in the city, deposits of the past decades of war, lacking collection and treatment of raw inter-city wastes which call for solutions to protect consumer and producer health and increase reliability of UPA productions. A cost-revenue analysis of all inputs and outputs of cereal, vegetable and grapes production systems over two years showed substantial differences in net UPA household income. To confirm these results, more detailed studies are needed, but tailoring and managing the optimal application of inputs to crop needs will significantly enhance farmer’s better revenues as will as environmental and produce quality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Three different drying methods, a forced convection double-pass solar drier (DPSD), typical cabinet type natural convection solar drier (CD) and traditional open-sun drying (OSD) were used for draying of bamboo shoots in central Vietnam. During drying the operational parameters such as drying temperature, relative humidity, air velocity, insolation and water evaporation have been recorded hourly. The mean drying temperatures and relative humidity in the drying chamber were 55.2°C, 23.7%; 47.5°C, 37,6%; 36.2°C, 47.8% in DPSD, CD and OSD, respectively. The mean global radiation during all experimental runs was 670 Wm^−2. The result also shows that fastest drying process was occurred in DPSD where the falling-rate period was achieved after 7 hours, in change to OSD where it took 16 hours. The overall drying efficiency was 23.11%, 15.83% and 9.73% in case of DPSD, CD and OSD, respectively. Although the construction cost of DPSD was significantly higher than in CD, the drying costs per one kilogram of bamboo shoots were by 42.8% lower in case of DPSD as compared to CD. Double-pass solar drier was found to be technically and economically suitable for drying of bamboo shoots under the specific conditions in central Vietnam and in all cases, the use of this drier led to considerable reduction in drying time in comparison to traditional open-sun drying.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present study examines the level of pure technical and scale efficiencies of cassava production system including its sub-processes (that is production and processing stages) of 278 cassava farmers/processors from three regions of Delta State, Nigeria by applying Two-Stage Data Envelopment Analysis (DEA) approach. Results reveal that pure technical efficiency (PTE) is significantly lower at the production stage 0.41 vs 0.55 for the processing stage, but scale efficiency (SE) is high at both stages (0.84 and 0.87), implying that productivity can be improved substantially by reallocation of resources and adjusting operation size. The socio-economic determinants exert differential impacts on PTE and SE at each stage. Overall, education, experience and main occupation as farmer significantly improve SE while subsistence pressure reduces it. Extension contact significantly improves SE at the processing stage but reduces PTE and SE overall. Inverse size-PTE and size-SE relationships exist in cassava production system. In other words, large/medium farms are technically and scale inefficient. Gender gap exists in performance. Male farmers are technically efficient at processing stage but scale inefficient overall. Farmers in northern region are technically efficient. Investments in education, extension services and infrastructure are suggested as policy options to improve the cassava sector in Nigeria.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper estimates a translog stochastic production function to examine the determinants of technical efficiency of freshwater prawn farming in Bangladesh. Primary data has been collected using random sampling from 90 farmers of three villages in southwestern Bangladesh. Prawn farming displayed much variability in technical efficiency ranging from 9.50 to 99.94% with mean technical efficiency of 65%, which suggested a substantial 35% of potential output can be recovered by removing inefficiency. For a land scarce country like Bangladesh this gain could help increase income and ensure better livelihood for the farmers. Based on the translog production function specification, farmers could be made scale efficient by providing more input to produce more output. The results suggest that farmers’ education and non-farm income significantly improve efficiency whilst farmers’ training, farm distance from the water canal and involvement in fish farm associations reduces efficiency. Hence, the study proposes strategies such as less involvement in farming-related associations and raising the effective training facilities of the farmers as beneficial adjustments for reducing inefficiency. Moreover, the key policy implication of the analysis is that investment in primary education would greatly improve technical efficiency.