5 resultados para Library extension.

em Universitätsbibliothek Kassel, Universität Kassel, Germany


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A stand-alone power system is an autonomous system that supplies electricity to the user load without being connected to the electric grid. This kind of decentralized system is frequently located in remote and inaccessible areas. It is essential for about one third of the world population which are living in developed or isolated regions and have no access to an electricity utility grid. The most people live in remote and rural areas, with low population density, lacking even the basic infrastructure. The utility grid extension to these locations is not a cost effective option and sometimes technically not feasible. The purpose of this thesis is the modelling and simulation of a stand-alone hybrid power system, referred to as “hydrogen Photovoltaic-Fuel Cell (PVFC) hybrid system”. It couples a photovoltaic generator (PV), an alkaline water electrolyser, a storage gas tank, a proton exchange membrane fuel cell (PEMFC), and power conditioning units (PCU) to give different system topologies. The system is intended to be an environmentally friendly solution since it tries maximising the use of a renewable energy source. Electricity is produced by a PV generator to meet the requirements of a user load. Whenever there is enough solar radiation, the user load can be powered totally by the PV electricity. During periods of low solar radiation, auxiliary electricity is required. An alkaline high pressure water electrolyser is powered by the excess energy from the PV generator to produce hydrogen and oxygen at a pressure of maximum 30bar. Gases are stored without compression for short- (hourly or daily) and long- (seasonal) term. A proton exchange membrane (PEM) fuel cell is used to keep the system’s reliability at the same level as for the conventional system while decreasing the environmental impact of the whole system. The PEM fuel cell consumes gases which are produced by an electrolyser to meet the user load demand when the PV generator energy is deficient, so that it works as an auxiliary generator. Power conditioning units are appropriate for the conversion and dispatch the energy between the components of the system. No batteries are used in this system since they represent the weakest when used in PV systems due to their need for sophisticated control and their short lifetime. The model library, ISET Alternative Power Library (ISET-APL), is designed by the Institute of Solar Energy supply Technology (ISET) and used for the simulation of the hybrid system. The physical, analytical and/or empirical equations of each component are programmed and implemented separately in this library for the simulation software program Simplorer by C++ language. The model parameters are derived from manufacturer’s performance data sheets or measurements obtained from literature. The identification and validation of the major hydrogen PVFC hybrid system component models are evaluated according to the measured data of the components, from the manufacturer’s data sheet or from actual system operation. Then, the overall system is simulated, at intervals of one hour each, by using solar radiation as the primary energy input and hydrogen as energy storage for one year operation. A comparison between different topologies, such as DC or AC coupled systems, is carried out on the basis of energy point of view at two locations with different geographical latitudes, in Kassel/Germany (Europe) and in Cairo/Egypt (North Africa). The main conclusion in this work is that the simulation method of the system study under different conditions could successfully be used to give good visualization and comparison between those topologies for the overall performance of the system. The operational performance of the system is not only depending on component efficiency but also on system design and consumption behaviour. The worst case of this system is the low efficiency of the storage subsystem made of the electrolyser, the gas storage tank, and the fuel cell as it is around 25-34% at Cairo and 29-37% at Kassel. Therefore, the research for this system should be concentrated in the subsystem components development especially the fuel cell.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this paper is to indicate how TOSCANA may be extended to allow graphical representations not only of concept lattices but also of concept graphs in the sense of Contextual Logic. The contextual-logic extension of TOSCANA requires the logical scaling of conceptual and relatioal scales for which we propose the Peircean Algebraic Logic as reconstructed by R. W. Burch. As graphical representations we recommend, besides labelled line diagrams of concept lattices and Sowa's diagrams of conceptual graphs, particular information maps for utilizing background knowledge as much as possible. Our considerations are illustrated by a small information system about the domestic flights in Austria.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The component structure of a 34-item scale measuring different aspects of job satisfaction was investigated among extension officers in North West Province, South Africa. A simple random sampling technique was used to select 40 extension officers from which data were collected. A structured questionnaire consisting of 34 job satisfaction and 10 personal characteristic items was administered to the extension officers. Items on job satisfaction were measured at interval level and analyzedwith Principal ComponentAnalysis. Most of the respondents (82.5%) weremales, between 40 to 45 years, 85% were married and 87.5% had a diploma as their educational qualification. Furthermore, 54% of the households size between 4 to 6 persons, whereas 75% were Christians. The majority of the extension officers lived in their job area (82.5), while 80% covered at least 3 communities and 3 farmer groups. In terms of number of farmers covered, only 40% of the extension officers covered more than 500 farmers and 45% travelled more than 40 km to reach their farmers. From the job satisfaction items 9 components were extracted to show areas for job satisfaction among extension officers. These were in-service training, research policies, communicating recommended practices, financial support for self and family, quality of technical help, opportunity to advance education, management and control of operations, rewarding system and sanctions. The results have several implications for motivating extension officers for high job performance especially with large number of clients and small number of extension agents.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The possibility to develop automatically running models which can capture some of the most important factors driving the urban climate would be very useful for many planning aspects. With the help of these modulated climate data, the creation of the typically used “Urban Climate Maps” (UCM) will be accelerated and facilitated. This work describes the development of a special ArcGIS software extension, along with two support databases to achieve this functionality. At the present time, lacking comparability between different UCMs and imprecise planning advices going along with the significant technical problems of manually creating conventional maps are central issues. Also inflexibility and static behaviour are reducing the maps’ practicality. From experi-ence, planning processes are formed more productively, namely to implant new planning parameters directly via the existing work surface to map the impact of the data change immediately, if pos-sible. In addition to the direct climate figures, information of other planning areas (like regional characteristics / developments etc.) have to be taken into account to create the UCM as well. Taking all these requirements into consideration, an automated calculation process of urban climate impact parameters will serve to increase the creation of homogenous UCMs efficiently.