2 resultados para BEAM-TO-COLUMN CONNECTION
em Universitätsbibliothek Kassel, Universität Kassel, Germany
Resumo:
To study the behaviour of beam-to-column composite connection more sophisticated finite element models is required, since component model has some severe limitations. In this research a generic finite element model for composite beam-to-column joint with welded connections is developed using current state of the art local modelling. Applying mechanically consistent scaling method, it can provide the constitutive relationship for a plane rectangular macro element with beam-type boundaries. Then, this defined macro element, which preserves local behaviour and allows for the transfer of five independent states between local and global models, can be implemented in high-accuracy frame analysis with the possibility of limit state checks. In order that macro element for scaling method can be used in practical manner, a generic geometry program as a new idea proposed in this study is also developed for this finite element model. With generic programming a set of global geometric variables can be input to generate a specific instance of the connection without much effort. The proposed finite element model generated by this generic programming is validated against testing results from University of Kaiserslautern. Finally, two illustrative examples for applying this macro element approach are presented. In the first example how to obtain the constitutive relationships of macro element is demonstrated. With certain assumptions for typical composite frame the constitutive relationships can be represented by bilinear laws for the macro bending and shear states that are then coupled by a two-dimensional surface law with yield and failure surfaces. In second example a scaling concept that combines sophisticated local models with a frame analysis using a macro element approach is presented as a practical application of this numerical model.
Resumo:
At the Institute of Structural Engineering of the Faculty of Civil Engineering, Kassel University, series tests of slab-column connection were carried out, subjected to concentrated punching load. The effects of steel fiber content, concrete compressive strength, tension reinforcement ratio, size effect, and yield stress of tension reinforcement were studied by testing a total of six UHPC slabs and one normal strength concrete slab. Based on experimental results; all the tested slabs failed in punching shear as a type of failure, except the UHPC slab without steel fiber which failed due to splitting of concrete cover. The post ultimate load-deformation behavior of UHPC slabs subjected to punching load shows harmonic behavior of three stages; first, drop of load-deflection curve after reaching maximum load, second, resistance of both steel fibers and tension reinforcement, and third, pure tension reinforcement resistance. The first shear crack of UHPC slabs starts to open at a load higher than that of normal strength concrete slabs. Typically, the diameter of the punching cone for UHPC slabs on the tension surface is larger than that of NSC slabs and the location of critical shear crack is far away from the face of the column. The angle of punching cone for NSC slabs is larger than that of UHPC slabs. For UHPC slabs, the critical perimeter is proposed and located at 2.5d from the face of the column. The final shape of the punching cone is completed after the tension reinforcement starts to yield and the column stub starts to penetrate through the slab. A numerical model using Finite Element Analysis (FEA) for UHPC slabs is presented. Also some variables effect on punching shear is demonstrated by a parametric study. A design equation for UHPC slabs under punching load is presented and shown to be applicable for a wide range of parametric variations; in the ranges between 40 mm to 300 mm in slab thickness, 0.1 % to 2.9 % in tension reinforcement ratio, 150 MPa to 250 MPa in compressive strength of concrete and 0.1 % to 2 % steel fiber content. The proposed design equation of UHPC slabs is modified to include HSC and NSC slabs without steel fiber, and it is checked with the test results from earlier researches.