4 resultados para AMPEROMETRIC BIOSENSORS
em Universitätsbibliothek Kassel, Universität Kassel, Germany
Resumo:
The aim of the thesis is to theoretically investigate optical/plasmonic antennas for biosensing applications. The full 3-D numerical electromagnetic simulations have been performed by using finite integration technique (FIT). The electromagnetic properties of surface plasmon polaritons (SPPs) and the localized surface plasmons (LSPs) based devices are studied for sensing purpose. The surface plasmon resonance (SPR) biosensors offer high refractive index sensitivity at a fixed wavelength but are not enough for the detection of low concentrations of molecules. It has been demonstrated that the sensitivity of SPR sensors can be increased by employing the transverse magneto-optic Kerr effect (TMOKE) in combination with SPPs. The sensor based on the phenomena of TMOKE and SPPs are known as magneto-optic SPR (MOSPR) sensors. The optimized MOSPR sensor is analyzed which provides 8 times higher sensitivity than the SPR sensor, which will be able to detect lower concentration of molecules. But, the range of the refractive index detection is limited, due to the rapid decay of the amplitude of the MOSPR-signal with the increase of the refractive indices. Whereas, LSPs based sensors can detect lower concentrations of molecules, but their sensitivity is small at a fixed wavelength. Therefore, another device configuration known as perfect plasmonic absorber (PPA) is investigated which is based on the phenomena of metal-insulator-metal (MIM) waveguide. The PPA consists of a periodic array of gold nanoparticles and a thick gold film separated by a dielectric spacer. The electromagnetic modes of the PPA system are analyzed for sensing purpose. The second order mode of the PPA at a fixed wavelength has been proposed for the first time for biosensing applications. The PPA based sensor combines the properties of the LSPR sensor and the SPR sensor, for example, it illustrates increment in sensitivity of the LSPR sensor comparable to the SPR and can detect lower concentration of molecules due to the presence of nanoparticles.
Resumo:
Die Wechselwirkungen zwischen Biomolekülen spielen eine zentrale Rolle in der biochemischen und pharmazeutischen Forschung. In der biomolekularen Interaktionsanalyse sind dabei Biosensoren auf Basis des Oberflächenplasmonresonanzeffekts (SPR-Effekt) weitverbreitet. Seit Einführung der ersten kommerziellen SPR-Biosensoren Anfang der 1990er Jahre wurden verschiedenste Messanordnungen sowie Materialsysteme mit dem Ziel einer möglichst hohen Empfindlichkeit getestet. Eine Möglichkeit zur Steigerung der Empfindlichkeit klassischer SPR-Systeme bieten sogenannte magneto-optische SPR-Biosensoren (MOSPR-Biosensoren). Grundlage der Empfindlichkeitssteigerung ist die gleichzeitige Messung des SPR-Effekts und des transversalen magneto-optischen KERR-Effekts (tMOKE). Bisherige Untersuchungen haben sich meist auf den Einfluss der Magnetisierung freier ferromagnetischer Schichten beschränkt. Im Rahmen dieser Arbeit wurden erstmals austauschverschobene Dünnschichtsysteme (EB-Systeme), eine Kombination aus Ferromagnet und Antiferromagnet, hinsichtlich ihrer Eignung für SPR- und MOSPR-basierte biosensorische Anwendungen untersucht. Aufgrund der remanenten Magnetisierung der ferromagnetischen Schicht und ihrer magnetischen Strukturierbarkeit sind EB-Systeme eine hochinteressante Plattform zur Realisierung neuer Biosensorkonzepte. Zur Reduzierung der stark dämpfendenden Wirkung magnetischer Materialien wurde das hier betrachtete IrMn/Co EB-System zwischen zwei Goldschichten eingebettet. Eine Gegenüberstellung optimierter Au/ IrMn/Co/Au-Systeme mit einem reinen Au-System, wie es typischerweise in kommerziellen SPR-basierten Biosensoren eingesetzt wird, demonstriert, dass mit den entwickelten EB-Systemen vergleichbare Empfindlichkeiten in SPR-Sensor-Anwendungen erreicht werden können. Die magneto-optische Aktivität der untersuchten Dünnschichtsysteme liegt im Bereich der Literaturwerte für Au/Co/Au-Systeme, mit denen erhöhte Empfindlichkeiten gegenüber Standard-SPR-Biosensoren realisiert wurden. Auf Grundlage magnetisch strukturierter Au/IrMn/Co/Au-Systeme wurden neue Biosensorkonzepte entwickelt und getestet. Erste Experimente belegen, dass mit diesen Schichtsystemen eine gleichzeitige Detektion der magnetisierungsabhängigen Reflektivitäten in ortsauflösenden MOSPR-Messungen möglich ist. Eine solche Messanordnung profitiert von der erhöhten Empfindlichkeit MOSPR-basierter Biosensoren, hohen Messgeschwindigkeiten und einem verbesserten Signal-Rausch-Verhältnis. Weiterhin wurde der domänenwandassistierte Transport (DOWMAT) superparamagnetischer Partikel über der Oberfläche eines exemplarischen EB-Systems, zur Sensorintegration von Misch-, Reinigungs- und Aufkonzentrationsfunktionen erfolgreich getestet. Die Ergebnisse demonstrieren, dass ein Transport von Partikelreihen mit hohen Geschwindigkeiten bei moderaten externen Magnetfeldern über den entwickelten Schichtsystemen möglich ist. Die Agglomeration der Partikel wird dabei intrinsisch vermieden. Diese Beobachtungen verdeutlichen die Vorzüge des DOWMAT-Mechanismus für biosensorische Anwendungen. Die präsentierten Untersuchungen bilden die Grundlage auf dem Weg zur Umsetzung neuer vielversprechender Biosensorkonzepte, die eine Schlüsselfunktion in der medizinischen point-of-care-Diagnostik bei der Detektion kleinster Konzentrationen krankheitsrelevanter Biomarker einnehmen können.
Resumo:
Chromaffin cells release catecholamines by exocytosis, a process that includes vesicle docking, priming and fusion. Although all these steps have been intensively studied, some aspects of their mechanisms, particularly those regarding vesicle transport to the active sites situated at the membrane, are still unclear. In this work, we show that it is possible to extract information on vesicle motion in Chromaffin cells from the combination of Langevin simulations and amperometric measurements. We developed a numerical model based on Langevin simulations of vesicle motion towards the cell membrane and on the statistical analysis of vesicle arrival times. We also performed amperometric experiments in bovine-adrenal Chromaffin cells under Ba2+ stimulation to capture neurotransmitter releases during sustained exocytosis. In the sustained phase, each amperometric peak can be related to a single release from a new vesicle arriving at the active site. The amperometric signal can then be mapped into a spike-series of release events. We normalized the spike-series resulting from the current peaks using a time-rescaling transformation, thus making signals coming from different cells comparable. We discuss why the obtained spike-series may contain information about the motion of all vesicles leading to release of catecholamines. We show that the release statistics in our experiments considerably deviate from Poisson processes. Moreover, the interspike-time probability is reasonably well described by two-parameter gamma distributions. In order to interpret this result we computed the vesicles’ arrival statistics from our Langevin simulations. As expected, assuming purely diffusive vesicle motion we obtain Poisson statistics. However, if we assume that all vesicles are guided toward the membrane by an attractive harmonic potential, simulations also lead to gamma distributions of the interspike-time probability, in remarkably good agreement with experiment. We also show that including the fusion-time statistics in our model does not produce any significant changes on the results. These findings indicate that the motion of the whole ensemble of vesicles towards the membrane is directed and reflected in the amperometric signals. Our results confirm the conclusions of previous imaging studies performed on single vesicles that vesicles’ motion underneath plasma membranes is not purely random, but biased towards the membrane.
Resumo:
Die Miniaturisierung von konventioneller Labor- und Analysetechnik nimmt eine zentrale Rolle im Bereich der allgemeinen Lebenswissenschaften und medizinischen Diagnostik ein. Neuartige und preiswerte Technologieplattformen wie Lab-on-a-Chip (LOC) oder Mikrototalanalysesysteme (µTAS) versprechen insbesondere im Bereich der Individualmedizin einen hohen gesellschaftlichen Nutzen zur frühzeitigen und nichtinvasiven Diagnose krankheitsspezifischer Indikatoren. Durch den patientennahen Einsatz preiswerter und verlässlicher Mikrochips auf Basis hoher Qualitätsstandards entfallen kostspielige und zeitintensive Zentrallaboranalysen, was gleichzeitig Chancen für den globalen Einsatz - speziell in Schwellen- und Entwicklungsländern - bietet. Die technischen Herausforderungen bei der Realisierung moderner LOC-Systeme sind in der kontrollierten und verlässlichen Handhabung kleinster Flüssigkeitsmengen sowie deren diagnostischem Nachweis begründet. In diesem Kontext wird der erfolgreichen Integration eines fernsteuerbaren Transports von biokompatiblen, magnetischen Mikro- und Nanopartikeln eine Schlüsselrolle zugesprochen. Die Ursache hierfür liegt in der vielfältigen Einsetzbarkeit, die durch die einzigartigen Materialeigenschaften begründet sind. Diese reichen von der beschleunigten, aktiven Durchmischung mikrofluidischer Substanzvolumina über die Steigerung der molekularen Interaktionsrate in Biosensoren bis hin zur Isolation und Aufreinigung von krankheitsspezifischen Indikatoren. In der Literatur beschriebene Ansätze basieren auf der dynamischen Transformation eines makroskopischen, zeitabhängigen externen Magnetfelds in eine mikroskopisch veränderliche potentielle Energielandschaft oberhalb magnetisch strukturierter Substrate, woraus eine gerichtete und fernsteuerbare Partikelbewegung resultiert. Zentrale Kriterien, wie die theoretische Modellierung und experimentelle Charakterisierung der magnetischen Feldlandschaft in räumlicher Nähe zur Oberfläche der strukturierten Substrate sowie die theoretische Beschreibung der Durchmischungseffekte, wurden jedoch bislang nicht näher beleuchtet, obwohl diese essentiell für ein detailliertes Verständnis der zu Grunde liegenden Mechanismen und folglich für einen Markteintritt zukünftiger Geräte sind. Im Rahmen der vorgestellten Arbeit wurde daher ein neuartiger Ansatz zur erfolgreichen Integration eines Konzepts zum fernsteuerbaren Transport magnetischer Partikel zur Anwendung in modernen LOC-Systemen unter Verwendung von magnetisch strukturierten Exchange-Bias (EB) Dünnschichtsystemen verfolgt. Die Ergebnisse zeigen, dass sich das Verfahren der ionenbe-schussinduzierten magnetischen Strukturierung (IBMP) von EB-Systemen zur Herstellung von maßgeschneiderten magnetischen Feldlandschaften (MFL) oberhalb der Substratoberfläche, deren Stärke und räumlicher Verlauf auf Nano- und Mikrometerlängenskalen gezielt über die Veränderung der Materialparameter des EB-Systems via IBMP eingestellt werden kann, eignet. Im Zuge dessen wurden erstmals moderne, experimentelle Verfahrenstechniken (Raster-Hall-Sonden-Mikroskopie und rastermagnetoresistive Mikroskopie) in Kombination mit einem eigens entwickelten theoretischen Modell eingesetzt, um eine Abbildung der MFL in unterschiedlichen Abstandsbereichen zur Substratoberfläche zu realisieren. Basierend auf der quantitativen Kenntnis der MFL wurde ein neuartiges Konzept zum fernsteuerbaren Transport magnetischer Partikel entwickelt, bei dem Partikelgeschwindigkeiten im Bereich von 100 µm/s unter Verwendung von externen Magnetfeldstärken im Bereich weniger Millitesla erzielt werden können, ohne den magnetischen Zustand des Substrats zu modifizieren. Wie aus den Untersuchungen hervorgeht, können zudem die Stärke des externen Magnetfelds, die Stärke und der Gradient der MFL, das magnetfeldinduzierte magnetische Moment der Partikel sowie die Größe und der künstlich veränderliche Abstand der Partikel zur Substratoberfläche als zentrale Einflussgrößen zur quantitativen Modifikation der Partikelgeschwindigkeit genutzt werden. Abschließend wurde erfolgreich ein numerisches Simulationsmodell entwickelt, das die quantitative Studie der aktiven Durchmischung auf Basis des vorgestellten Partikeltransportkonzepts von theoretischer Seite ermöglicht, um so gezielt die geometrischen Gegebenheiten der mikrofluidischen Kanalstrukturen auf einem LOC-System für spezifische Anwendungen anzupassen.