44 resultados para Focused Ion Beam
Resumo:
The motion of a vibrational wave packet in the bound A(^1 \summe^+_u) electronic state of the sodium dimer is detected in a femtosecond pump/probe molecular beam experiment. For short times harmonic motion is seen in the total ion yield of Na^+_2 as a function of delay time between the two laser pulses. The spreading of the wave packet results in the loss of the periodic variation of the ion signal. For longer delay times (47 ps) the wave packet regains its initial form which is reflected in the revival structure of the Na^+_2 signal. Time-dependent quantum calculations reproduce the measured effects.
Resumo:
The real-time dynamics of multiphoton ionization and fragmentation of molecules - Na_2 , Na_3 - and clusters - Na_n, Hg_n - has been studied in molecular beam experiments employing ion and electron spectroscopy together with femtosecond pump-probe techniques. Experiments with Na_2 and Na_3 reveal unexpected features of the dynamics of the absorption of several photons as seen in the one- and three dimensional vibrational wave packet motion in different potential surfaces and in high laser fields. Cluster size dependent studies of physical properties such as absorption resonances, lifetimes and decay channels have been performed using tunable femtosecond light pulses in resonance enhanced multiphoton ionization (REMPI) of the cluster size under investigation. This method failed in ns-laser experiments due to the ultrafast decay of the studied cluster. For Na_n, cluster we find that for cluster sizes n \le 21 molecular excitations and properties prevail over collective excitations of plasmon-like resonances. In the case of Hg_n cluster prompt formation of singly and doubly charged cluster are observed up to n \approx 60. The transient multiphoton ionization spectra show a 'short' time wave packet dynamics, which is identical for singly and doubly charged mercury clusters while the 'long' time fragmentation dynamics is different.
Resumo:
Femtosecond reaction dynamics of OClO in a supersonic molecular beam are reported. The system is excited to the A^2A_2 state with a femtosecond pulse, covering a range of excitation in the symmetric stretch between v_1 = 17 to v_1 = 11 (308-352 nm). A time-delayed femtosecond probe pulse ionizes the OClO, and OClO^+ is detected. This ion has not been observed in previous experiments because of its ultrafast fragmentation. Transients are reported for the mass of the parent OClO as well as the mass of the ClO. Apparent biexponential decays are observed and related to the fragmentation dynamics: OClO+hv \rightarrow (OClO)^{(++)*} \rightarrow ClO+O \rightarrow Cl+O_2. Clusters of OClO with water (OClO)_n (H_2 0)_m with n from 1 to 3 and m from 0 to 3 are also observed. The dynamics of the fragmentation reveal the nuclear motions and the electronic coupling between surfaces. The time scale for bond breakage is in the range of 300-500 fs, depending on v_1; surface crossing to form new intermediates is a pathway for the two channels of fragmentation: ClO+O (primary) and Cl+O_2 (minor). Comparisons with results of ab initio calculations are made.
Resumo:
Optische Spektroskopie ist eine sehr wichtige Messtechnik mit einem hohen Potential für zahlreiche Anwendungen in der Industrie und Wissenschaft. Kostengünstige und miniaturisierte Spektrometer z.B. werden besonders für moderne Sensorsysteme “smart personal environments” benötigt, die vor allem in der Energietechnik, Messtechnik, Sicherheitstechnik (safety and security), IT und Medizintechnik verwendet werden. Unter allen miniaturisierten Spektrometern ist eines der attraktivsten Miniaturisierungsverfahren das Fabry Pérot Filter. Bei diesem Verfahren kann die Kombination von einem Fabry Pérot (FP) Filterarray und einem Detektorarray als Mikrospektrometer funktionieren. Jeder Detektor entspricht einem einzelnen Filter, um ein sehr schmales Band von Wellenlängen, die durch das Filter durchgelassen werden, zu detektieren. Ein Array von FP-Filter wird eingesetzt, bei dem jeder Filter eine unterschiedliche spektrale Filterlinie auswählt. Die spektrale Position jedes Bandes der Wellenlänge wird durch die einzelnen Kavitätshöhe des Filters definiert. Die Arrays wurden mit Filtergrößen, die nur durch die Array-Dimension der einzelnen Detektoren begrenzt werden, entwickelt. Allerdings erfordern die bestehenden Fabry Pérot Filter-Mikrospektrometer komplizierte Fertigungsschritte für die Strukturierung der 3D-Filter-Kavitäten mit unterschiedlichen Höhen, die nicht kosteneffizient für eine industrielle Fertigung sind. Um die Kosten bei Aufrechterhaltung der herausragenden Vorteile der FP-Filter-Struktur zu reduzieren, wird eine neue Methode zur Herstellung der miniaturisierten FP-Filtern mittels NanoImprint Technologie entwickelt und präsentiert. In diesem Fall werden die mehreren Kavitäten-Herstellungsschritte durch einen einzigen Schritt ersetzt, die hohe vertikale Auflösung der 3D NanoImprint Technologie verwendet. Seit dem die NanoImprint Technologie verwendet wird, wird das auf FP Filters basierende miniaturisierte Spectrometer nanospectrometer genannt. Ein statischer Nano-Spektrometer besteht aus einem statischen FP-Filterarray auf einem Detektorarray (siehe Abb. 1). Jeder FP-Filter im Array besteht aus dem unteren Distributed Bragg Reflector (DBR), einer Resonanz-Kavität und einen oberen DBR. Der obere und untere DBR sind identisch und bestehen aus periodisch abwechselnden dünnen dielektrischen Schichten von Materialien mit hohem und niedrigem Brechungsindex. Die optischen Schichten jeder dielektrischen Dünnfilmschicht, die in dem DBR enthalten sind, entsprechen einen Viertel der Design-Wellenlänge. Jeder FP-Filter wird einer definierten Fläche des Detektorarrays zugeordnet. Dieser Bereich kann aus einzelnen Detektorelementen oder deren Gruppen enthalten. Daher werden die Seitenkanal-Geometrien der Kavität aufgebaut, die dem Detektor entsprechen. Die seitlichen und vertikalen Dimensionen der Kavität werden genau durch 3D NanoImprint Technologie aufgebaut. Die Kavitäten haben Unterschiede von wenigem Nanometer in der vertikalen Richtung. Die Präzision der Kavität in der vertikalen Richtung ist ein wichtiger Faktor, der die Genauigkeit der spektralen Position und Durchlässigkeit des Filters Transmissionslinie beeinflusst.
Resumo:
To study the behaviour of beam-to-column composite connection more sophisticated finite element models is required, since component model has some severe limitations. In this research a generic finite element model for composite beam-to-column joint with welded connections is developed using current state of the art local modelling. Applying mechanically consistent scaling method, it can provide the constitutive relationship for a plane rectangular macro element with beam-type boundaries. Then, this defined macro element, which preserves local behaviour and allows for the transfer of five independent states between local and global models, can be implemented in high-accuracy frame analysis with the possibility of limit state checks. In order that macro element for scaling method can be used in practical manner, a generic geometry program as a new idea proposed in this study is also developed for this finite element model. With generic programming a set of global geometric variables can be input to generate a specific instance of the connection without much effort. The proposed finite element model generated by this generic programming is validated against testing results from University of Kaiserslautern. Finally, two illustrative examples for applying this macro element approach are presented. In the first example how to obtain the constitutive relationships of macro element is demonstrated. With certain assumptions for typical composite frame the constitutive relationships can be represented by bilinear laws for the macro bending and shear states that are then coupled by a two-dimensional surface law with yield and failure surfaces. In second example a scaling concept that combines sophisticated local models with a frame analysis using a macro element approach is presented as a practical application of this numerical model.
Resumo:
The main focus and concerns of this PhD thesis is the growth of III-V semiconductor nanostructures (Quantum dots (QDs) and quantum dashes) on silicon substrates using molecular beam epitaxy (MBE) technique. The investigation of influence of the major growth parameters on their basic properties (density, geometry, composition, size etc.) and the systematic characterization of their structural and optical properties are the core of the research work. The monolithic integration of III-V optoelectronic devices with silicon electronic circuits could bring enormous prospect for the existing semiconductor technology. Our challenging approach is to combine the superior passive optical properties of silicon with the superior optical emission properties of III-V material by reducing the amount of III-V materials to the very limit of the active region. Different heteroepitaxial integration approaches have been investigated to overcome the materials issues between III-V and Si. However, this include the self-assembled growth of InAs and InGaAs QDs in silicon and GaAx matrices directly on flat silicon substrate, sitecontrolled growth of (GaAs/In0,15Ga0,85As/GaAs) QDs on pre-patterned Si substrate and the direct growth of GaP on Si using migration enhanced epitaxy (MEE) and MBE growth modes. An efficient ex-situ-buffered HF (BHF) and in-situ surface cleaning sequence based on atomic hydrogen (AH) cleaning at 500 °C combined with thermal oxide desorption within a temperature range of 700-900 °C has been established. The removal of oxide desorption was confirmed by semicircular streaky reflection high energy electron diffraction (RHEED) patterns indicating a 2D smooth surface construction prior to the MBE growth. The evolution of size, density and shape of the QDs are ex-situ characterized by atomic-force microscopy (AFM) and transmission electron microscopy (TEM). The InAs QDs density is strongly increased from 108 to 1011 cm-2 at V/III ratios in the range of 15-35 (beam equivalent pressure values). InAs QD formations are not observed at temperatures of 500 °C and above. Growth experiments on (111) substrates show orientation dependent QD formation behaviour. A significant shape and size transition with elongated InAs quantum dots and dashes has been observed on (111) orientation and at higher Indium-growth rate of 0.3 ML/s. The 2D strain mapping derived from high-resolution TEM of InAs QDs embedded in silicon matrix confirmed semi-coherent and fully relaxed QDs embedded in defectfree silicon matrix. The strain relaxation is released by dislocation loops exclusively localized along the InAs/Si interfaces and partial dislocations with stacking faults inside the InAs clusters. The site controlled growth of GaAs/In0,15Ga0,85As/GaAs nanostructures has been demonstrated for the first time with 1 μm spacing and very low nominal deposition thicknesses, directly on pre-patterned Si without the use of SiO2 mask. Thin planar GaP layer was successfully grown through migration enhanced epitaxy (MEE) to initiate a planar GaP wetting layer at the polar/non-polar interface, which work as a virtual GaP substrate, for the GaP-MBE subsequently growth on the GaP-MEE layer with total thickness of 50 nm. The best root mean square (RMS) roughness value was as good as 1.3 nm. However, these results are highly encouraging for the realization of III-V optical devices on silicon for potential applications.
Resumo:
The accurate transport of an ion over macroscopic distances represents a challenging control problem due to the different length and time scales that enter and the experimental limitations on the controls that need to be accounted for. Here, we investigate the performance of different control techniques for ion transport in state-of-the-art segmented miniaturized ion traps. We employ numerical optimization of classical trajectories and quantum wavepacket propagation as well as analytical solutions derived from invariant based inverse engineering and geometric optimal control. The applicability of each of the control methods depends on the length and time scales of the transport. Our comprehensive set of tools allows us make a number of observations. We find that accurate shuttling can be performed with operation times below the trap oscillation period. The maximum speed is limited by the maximum acceleration that can be exerted on the ion. When using controls obtained from classical dynamics for wavepacket propagation, wavepacket squeezing is the only quantum effect that comes into play for a large range of trapping parameters. We show that this can be corrected by a compensating force derived from invariant based inverse engineering, without a significant increase in the operation time.
Resumo:
A Ramsey-type interferometer is suggested, employing a cold trapped ion and two time-delayed offresonant femtosecond laser pulses. The laser light couples to the molecular polarization anisotropy, inducing rotational wavepacket dynamics. An interferogram is obtained from the delay dependent populations of the final field-free rotational states. Current experimental capabilities for cooling and preparation of the initial state are found to yield an interferogram visibility of more than 80%. The interferograms can be used to determine the polarizability anisotropy with an accuracy of about ±2%, respectively ±5%, provided the uncertainty in the initial populations and measurement errors are confined to within the same limits.
Resumo:
Alle bisher untersuchten Lebewesen besitzen (circadiane) innere Uhren, die eine endogene Perioden-länge von ungefähr 24 Stunden generieren. Eine innere Uhr kann über Zeitgeber mit der Umwelt synchronisiert werden und ermöglicht dem Organismus, rhythmische Umweltveränderungen vorweg zu nehmen. Neben einem zentralen Schrittmacher, der Physiologie und Verhalten des Organismus steuert, gibt es in unterschiedlichen Organen auch periphere Uhren, die die zeitlichen Abläufe in der spezifischen Funktion dieser Organe steuern. In dieser Arbeit sollten zentrale und periphere Schrittmacherneurone von Insekten physiologisch untersucht und verglichen werden. Die Neurone der akzessorischen Medulla (AME) von Rhyparobia maderae dienten als Modellsystem für zentrale Schrittmacher, während olfaktorische Rezeptorneurone (ORNs) von Manduca sexta als Modellsystem für periphere Schrittmacher dienten. Die zentralen Schrittmacherneurone wurden in extrazellulären Ableitungen an der isolierten AME (Netzwerkebene) und in Patch-Clamp Experimenten an primären AME Zellkulturen (Einzelzellebene) untersucht. Auf Netzwerkebene zeigten sich zwei charakteristische Aktivitätsmuster: regelmäßige Aktivität und Wechsel zwischen hoher und niedriger Aktivität (Oszillationen). Es wurde gezeigt, dass Glutamat ein Neurotransmitter der weitverbreiteten inhibitorischen Synapsen der AME ist, und dass in geringem Maße auch exzitatorische Synapsen vorkommen. Das Neuropeptid pigment-dispersing factor (PDF), das von nur wenigen AME Neuronen exprimiert wird und ein wichtiger Kopplungsfaktor im circadianen System ist, führte zu Hemmungen, Aktivierungen oder Oszillationen. Die Effekte waren transient oder langanhaltend und wurden wahrscheinlich durch den sekundären Botenstoff cAMP vermittelt. Ein Zielmolekül von cAMP war vermutlich exchange protein directly activated by cAMP (EPAC). Auf Einzelzellebene wurde gezeigt, dass die meisten AME Neurone depolarisiert waren und deshalb nicht feuerten. Die Analyse von Strom-Spannungs-Kennlinien und pharmakologische Experimente ergaben, dass unterschiedliche Ionenkanäle vorhanden waren (Ca2+, Cl-, K+, Na+ Kanäle sowie nicht-spezifische Kationenkanäle). Starke, bei hohen Spannungen aktivierende Ca2+ Ströme (ICa) könnten eine wichtige Rolle bei Ca2+-abhängiger Neurotransmitter-Ausschüttung, Oszillationen, und Aktionspotentialen spielen. PDF hemmte unterschiedliche Ströme (ICa, IK und INa) und aktivierte nicht-spezifische Kationenströme (Ih). Es wurde angenommen, dass simultane PDF-abhängige Hyper- und Depolarisationen rhythmische Membranpotential-Oszillationen verursachen. Dieser Mechanismus könnte eine Rolle bei PDF-abhängigen Synchronisationen spielen. Die Analyse peripherer Schrittmacherneurone konzentrierte sich auf die Charakterisierung des olfaktorischen Corezeptors von M. sexta (MsexORCO). In anderen Insekten ist ORCO für die Membran-Insertion von olfaktorischen Rezeptoren (ORs) erforderlich. ORCO bildet Komplexe mit den ORs, die in heterologen Expressionssystemen als Ionenkanäle fungieren und Duft-Antworten vermitteln. Es wurde die Hypothese aufgestellt, dass MsexORCO in pheromonsensitiven ORNs in vivo nicht als Teil eines ionotropen Rezeptors sondern als Schrittmacherkanal fungiert, der unterschwellige Membranpotential-Oszillationen generiert. MsexORCO wurde mit vermeintlichen Pheromonrezeptoren in human embryonic kidney (HEK 293) Zellen coexprimiert. Immuncytochemie und Ca2+ Imaging Experimente zeigten sehr schwache Expressionsraten. Trotzdem war es möglich zu zeigen, dass MsexORCO wahrscheinlich ein spontan-aktiver, Ca2+-permeabler Ionenkanal ist, der durch den ORCO-Agonisten VUAA1 und cyclische Nucleotide aktiviert wird. Außerdem wiesen die Experimente darauf hin, dass MsexOR-1 offensichtlich der Bombykal-Rezeptor ist. Eine weitere Charakterisierung von MsexORCO in primären M. sexta ORN Zellkulturen konnte nicht vollendet werden, weil die ORNs nicht signifikant auf ORCO-Agonisten oder -Antagonisten reagierten.