4 resultados para steel pipelines
em Cochin University of Science
Resumo:
The main objective of carrying out this investigation is to develop suitable transducer array systems so that underwater pipeline inspection could be carried out in a much better way, a focused beam and electronic steering can reduce inspection time as well. Better results are obtained by optimizing the array parameters. The spacing between the elements is assumed to be half the wavelength so that the interelement interaction is minimum. For NDT applications these arrays are operated at MHz range. The wavelengths become very small in these frequency ranges. Then the size of the array elements becomes very small, requiring hybrid construction techniques for their fabrication. Transducer elements have been fabricated using PVDF as the active, mild steel as the backing and conducting silver preparation as the bonding materials. The transducer is operated in the (3,3) mode. The construction of a high frequency array is comparatively complicated. The interelement spacing between the transducer elements becomes considerably small when high frequencies are considered. It becomes very difficult to construct the transducer manually. The electrode connections to the elements can produce significant loading effect. The array has to be fabricated using hybrid construction techniques. The active materials has to be deposited on a proper substrate and etching techniques are required to fabricate the array. The annular ring, annular cylindrical or other similar structural forms of arrays may also find applications in the near future in treatments were curved contours of the human body are affected.
Resumo:
In the present work, Indigenous polymer coated Tin Free Steel cans were analyzed fortheir suitability for thermal processing and storage of fish and fish products following standard methods. The raw materials used for the development of ready to eat thermally processed fish products were found to be of fresh condition. The values for various biochemical and microbiological parameters of the raw materials were well within the limits. Based on the analysis of commercial sterility, instrumental colour, texture, WB-shear force and sensory parameters, squid masala processed to F0 value of 8 min with a total process time of 38.5 min and cook value of 92 min was chosen as the optimum for squid masala in tin free steel cans while shrimp curry processed to F0 7 min with total process time of 44.0 min and cook value of 91.1 min was found to be ideal and was selected for storage study. Squid masala and shrimp curry thermally processed in indigenous polymer coated TFS cans were found to be acceptable even after one year of storage at room temperaturebased on the analysis of various sensory and biochemical parameters. Analysis of the Commission Internationale d’ Eclirage L*, a* and b* color values showed that the duration of exposure to heat treatment influenced the color parameters: the lightness (L*) and yellowness (b*)decreased, and the redness (a*) significantly increased with the increase in processing time or reduction in processing temperature.Instrumental analysis of texture showed that hardness-1 & 2 decreased with reduction in retort temperature while cohesiveness value did not show any appreciable change with decrease in temperature of processing. Other texture profile parameters like gumminess, springiness and chewiness decreased significantly with increase of processing time. W-B shear force values of mackerel meat processed at 130 °C were significantly higher than those processed at 121.1 and 115 °C. HTST processing of mackerel in brine helped in reducing the process time and improving the quality.The study also indicated that indigenous polymer coated TFS cans with easy openends can be a viable alternative to the conventional tin and aluminium cans. The industry can utilize these cans for processing ready to eat fish and shell fish products for both domestic and export markets. This will help in reviving the canning industry in India.
Resumo:
This paper presents the results from an experimental program and an analytical assessment of the influence of addition of fibers on mechanical properties of concrete. Models derived based on the regression analysis of 60 test data for various mechanical properties of steel fiber-reinforced concrete have been presented. The various strength properties studied are cube and cylinder compressive strength, split tensile strength, modulus of rupture and postcracking performance, modulus of elasticity, Poisson’s ratio, and strain corresponding to peak compressive stress. The variables considered are grade of concrete, namely, normal strength 35 MPa , moderately high strength 65 MPa , and high-strength concrete 85 MPa , and the volume fraction of the fiber Vf =0.0, 0.5, 1.0, and 1.5% . The strength of steel fiber-reinforced concrete predicted using the proposed models have been compared with the test data from the present study and with various other test data reported in the literature. The proposed model predicted the test data quite accurately. The study indicates that the fiber matrix interaction contributes significantly to enhancement of mechanical properties caused by the introduction of fibers, which is at variance with both existing models and formulations based on the law of mixtures
Resumo:
Corrosion represents one of the largest through life cost component of ships. Ship owners and operators recognize that combating corrosion significantly impacts the vessels’ reliability, availability and through life costs. Primary objective of this paper is to review various inspections, monitoring systems and life cycle management with respect to corrosion control of ships and to develop the concept of “Corrosion Health” (CH) which would quantify the extent of corrosion at any point of ships’ operational life. A system approach in which the ship structure is considered as a corrosion system and divided into several corrosion zones, with distinct characteristics, is presented. Various corrosion assessment criteria for assessment of corrosion condition are listed. A CH rating system for representation of complex corrosion condition with a numeric number along with recommendations for repair/maintenance action is also discussed