2 resultados para Primary Productivity
em Cochin University of Science
Resumo:
The water quality and primary productivity of Valanthakad backwater (9° 55 10. 24 N latitude and 76° 20 01. 23 E longitude) was monitored from June to November 2007. Significant spatial and temporal variations in temperature, transparency, salinity, pH, dissolved oxygen, sulphides, carbon dioxide, alkalinity, biochemical oxygen demand, phosphatephosphorus, nitrate-nitrogen, nitrite-nitrogen as well as primary productivity could be observed from the study. Transparency was low (53.75 cm to 159 cm) during the active monsoon months when the intensity of solar radiation was minimum, which together with the run off from the land resulted in turbid waters in the study sites. The salinity in both the stations was low (0.10 ‰ to 4.69 ‰) except in August and November 2007. The presence of total sulphide (0.08 mg/ l to 1.84 mg/ l) and higher carbon dioxide (3 mg/ l to 17 mg/ l) could be due to hospital discharges and decaying slaughter house wastes in Station 1 and also from the mangrove vegetation in Station 2. Nitrate-nitrogen and phosphate-phosphorus depicted higher values and pronounced variations in the monsoon season. Maximum net primary production was seen in November (0.87 gC/ m3/ day) and was reported nil in September. The chlorophyll pigments showed higher values in July, August and November with a negative correlation with phosphate-phosphorus and nitrite-nitrogen. The study indicated that the water quality and productivity of Valanthakad backwater is impacted and is the first report from the region
Resumo:
Retting.of coconut husk is one of the major problems of pollution in the estuaries (Kayals) of Kerala. This paper discusses the salient features associated with the variation in gross and net primary productivity values in the Kadinarnkularn Kayal based on lortnightlydala from twosclected stations frorn Octobcr1987 to September 1988.The gross primary productivity value in the surface water ranged from 0.06 to 0.29gC/m3/day at Station Iand from 0.06 to 1.49gC/rn3/dayatstation II. In the bottom wateritrangcdfrorn oto 0.21 gC/m2/ day at station I whereas that at station II from 0.03 to 1.41gC/m3j day. The net productivity in the surface water at station I varied from 0 to 024 gC/m Iday Whereas that atstation II varied from 0.02to 1.44gC/m3Iday.AI the bottomwaterilvaried from ato 0.19gC/m3/ day at station I and from 0.01 to 1.21gC/m3/day at station II. The monsoon period showed the highest mean seasonal value at stations I and II. The total depletion of dissolved oxygen giving rise to anoxic condition coupled with the production of large quantities of hydrogen sulphide was found to be detrimental to the gross and net productivity values in the retting zone