4 resultados para Plug-in electric vehicles

em Cochin University of Science


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Raman spectra of the KTP single crystal are recorded in electric fields (dc and ac) applied along the polar axis c. Spectra with the laser beam focused near the cathode end, anode end and the centre of the crystal are recorded. The cathode end of the crystal develops a spot ‘grey track’ where the laser beam is focused after a lapse of 5 h from the application of a dc electric field of 38 V/cm. The spectra recorded at the cathode end after the application of field show variations in intensity of bands. A new band appears at 177 cm21. Changes in band intensities are explained on the basis of changes in polarizability of the crystal due to the movement of K1 ions along the polar axis. K1 ions accumulate at the cathode end, where the ‘Grey track’ formation occurs. The intensity enhancement observed for almost all bands in the ac field is attributed to the improvement of crystalline quality.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the absence of entry barrier or regulatory restrictions, Non Banking Financial Companies frantically grew and accessed the public deposit without any regulatory control. The deposit of NBFCs grew from Rs. 41.9 crore in 1971 to 53116.0 crore in 1997. This growth was the result of a combined effect of increase in the number of NBFCs and increase in the amount of deposits. The deposits amazed as above was invested in various assets especially that in motor vehicles by these asset financing NBFCs. Various tactics were adopted by these NBFCs and their agents for recovering the receivable outstanding from such assets. Both central government and RBI were concerned about the protection of depositors‘ interest and various committees were set up to frame a comprehensive regulation for the functioning of these NBFCs.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Inter-digital capacitive electrodes working as electric field sensors have been developed for touch panel applications. Evaluation circuits to convert variations in electric fields in such sensors into computer compatible data are commercially available. We report development of an Interdigital capacitive electrode working as a sensitive pressure sensor in the range 0-120 kPa. Essentially it is a touch/proximity sensor converted into a pressure sensor with a suitable elastomer buffer medium acting as the pressure transmitter. The performance of the sensor has been evaluated and reported. Such sensors can be made very economical in comparison to existing pressure sensors. Moreover, they are very convenient to be fabricated into sensor arrays involving a number of sensors for distributed pressure sensing applications such as in biomedical systems.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Unit commitment is an optimization task in electric power generation control sector. It involves scheduling the ON/OFF status of the generating units to meet the load demand with minimum generation cost satisfying the different constraints existing in the system. Numerical solutions developed are limited for small systems and heuristic methodologies find difficulty in handling stochastic cost functions associated with practical systems. This paper models Unit Commitment as a multi stage decision task and Reinforcement Learning solution is formulated through one efficient exploration strategy: Pursuit method. The correctness and efficiency of the developed solutions are verified for standard test systems