2 resultados para OLFACTORY-BULB

em Cochin University of Science


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Thermodynamic parameters of the atmosphere form part of the input to numerical forecasting models. Usually these parameters are evaluated from a thermodynamic diagram. Here, a technique is developed to evaluate these parameters quickly and accurately using a Fortran program. This technique is tested with four sets of randomly selected data and the results are in agreement with the results from the conventional method. This technique is superior to the conventional method in three respects: more accuracy, less computation time, and evaluation of additional parameters. The computation time for all the parameters on a PC AT 286 machine is II sec. This software, with appropriate modifications, can be used, for verifying various lines on a thermodynamic diagram

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The combined use of both radiosonde data and three-dimensional satellite derived data over ocean and land is useful for a better understanding of atmospheric thermodynamics. Here, an attempt is made to study the ther-modynamic structure of convective atmosphere during pre-monsoon season over southwest peninsular India utilizing satellite derived data and radiosonde data. The stability indices were computed for the selected stations over southwest peninsular India viz: Thiruvananthapuram and Cochin, using the radiosonde data for five pre- monsoon seasons. The stability indices studied for the region are Showalter Index (SI), K Index (KI), Lifted In-dex (LI), Total Totals Index (TTI), Humidity Index (HI), Deep Convective Index (DCI) and thermodynamic pa-rameters such as Convective Available Potential Energy (CAPE) and Convective Inhibition Energy (CINE). The traditional Showalter Index has been modified to incorporate the thermodynamics over tropical region. MODIS data over South Peninsular India is also used for the study. When there is a convective system over south penin-sular India, the value of LI over the region is less than −4. On the other hand, the region where LI is more than 2 is comparatively stable without any convection. Similarly, when KI values are in the range 35 to 40, there is a possibility for convection. The threshold value for TTI is found to be between 50 and 55. Further, we found that prior to convection, dry bulb temperature at 1000, 850, 700 and 500 hPa is minimum and the dew point tem-perature is a maximum, which leads to increase in relative humidity. The total column water vapor is maximum in the convective region and minimum in the stable region. The threshold values for the different stability indices are found to be agreeing with that reported in literature.