6 resultados para Lung Volume Measurements

em Cochin University of Science


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Iron pillared Montmorillonite has been synthesised and it is then wet impregnated with vanadia with different vanadia composition. These catalysts are characterised using conventional techniques such as XRD analysis,FTIR analysis and surface area and pore volume measurements. Acidity is measured using spectrophotometric monitoring of adsorption of perylene, thermogravimetric desorption of 2.6 dimethylpyridine and temperature programmed desorption of ammonia. Activity studies are done in the liquid phase. It has been concluded that Lewis acidic sites are responsible for the benzylation of toluene when the benzylating agent is benzyl chloride while Bronsted acidic sites are responsible when the reagent is benzyl alcohol.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Iron, aluminium and mixed iron aluminium pillared clays have been prepared by partial hydrolysis method and doped with IO% Mo, V and Cr. The samples have been characterised by XRD, FTIR and surface area and pore Volume measurements. The surface acid site distribution has been determined by temperature programmed desorption of ammonia. Vanadia incorporated systems show maximum acidity. Benzylation of o-xylene has been done as probe reaction to test catalytic activity. Benzyl chloride is a superior benzylating agent compared to benzyl alcohol in activity and selectivity. Cent percent selectivity towards monobenzylated product is obtained in all the cases. Fe pillared systems exhibit maximum activity. The catalytic activities of the systems can be correlated with the amount of strong add sites. The effects of various reaction variables on the reaction have been studied. Presence of moisture has a diminishing effect on the reaction rate.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Lanthana modified sol-gel titania is prepared through particulate sol-gel route and the physico-chemical characterizations of the prepared systems were done using X-Ray diffration, EDX, BET surface area-pore volume measurements and TG-DTG analysis. Benzophenone was observed to be the sole product in the TiO2 photocatalyzed oxidation of benzhydrol in oxygen purged acetonitrile. The influence of various parameters, like irradiation time, amount of catalyst, concentration of the catalyst and other factors on the photocatalytic oxidation has been investigated. The proposed mechanism envisages the involvement of a superoxide radical anion.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Chromia loaded sulfated titania has been synthesized via sol–gel route with different chromia loadings. These catalysts are characterized using conventional techniques such as XRD analysis, FTIR analysis, surface area and pore volume measurements, EDX, SEM and UV–Vis diffuse reflectance spectral analysis. Acidity is measured using spectrophotometric monitoring of adsorption of perylene, thermogravimetric desorption of 2,6-dimethylpyridine and temperature programmed desorption of ammonia. Activity studies are done in the liquid phase. It has been concluded that Lewis acid sites are responsible for the benzylation of arenes with benzyl chloride.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A novel cavity perturbation technique using coaxial cavity resonators for the measurement of complex permittivity of liquids is presented. The method employs two types of resonators (Resonator I and Resonator II). Resonator I operates in the frequency range 600 MHz-7 GHz and resonator II operates in the frequency range 4 GHz-14 GHz. The introduction of the capillary tube filled with the sample liquid into the coaxial resonator causes shifts in the resonance frequency and loaded Q-factor of the resonator. The shifts in the resonance frequency and loaded Q-factor are used to determine the real and imaginary parts of the complex permittivity of the sample liquid, respectively. Using this technique, the dielectric parameters of water and nitrobenzene are measured. The results are compared with those obtained using other standard methods. The sources of errors are analyzed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The effect of frequency, composition and temperature on the a.c. electrical conductivity were studied for the ceramic, Ni1–xZnxFe2O4, as well as the filler (Ni1–xZnxFe2O4) incorporated rubber ferrite composites (RFCs). Ni1–xZnxFe2O4 (where x varies from 0 to 1 in steps of 0×2) were prepared by usual ceramic techniques. They were then incorporated into a butyl rubber matrix according to a specific recipe. The a.c. electrical conductivity (sa.c.) calculations were carried out by using the data available from dielectric measurements and by employing a simple relationship. The a.c. conductivity values were found to be of the order of 10–3 S/m. Analysis of the results shows that sa.c. increases with increase of frequency and the change is same for both ceramic Ni1–xZnxFe2O4 and RFCs. sa.c. increases initially with the increase of zinc content and then decreases with increase of zinc. Same behaviour is observed for RFCs too. The dependence of sa.c. on the volume fraction of the magnetic filler was also studied and it was found that the a.c. conductivity of RFCs increases with increase of volume fraction of the magnetic filler. Temperature dependence of conductivity was studied for both ceramic and rubber ferrite composites. Conductivity shows a linear dependence with temperature in the case of ceramic samples