5 resultados para Electroactive
em Cochin University of Science
Resumo:
Dipyrromethene-Cu(II) derivatives possessing two dodecane alkyl chains have been used for the modification of gold electrodes. Electroactive host molecules have been incorporated into a lipophilic dodecanethiol SAM deposited onto gold electrodes through hydrophobic and van der Waals interactions (embedment technique). The presence of dipyrromethene-Cu(II) redox centers on the electrode surface was proved by cyclic voltammetry and Osteryoung square-wave voltammetry. The Au electrodes incorporating redox active Cu(II)-dipyrromethene SAMs were used for the direct voltammetric determination of paracetamol in human plasma.
Resumo:
A novel electrochemical sensor has been developed for the determination of nimesulide. The sensor is based on the NIM- molybdophosphoric acid (MPA) as the electroactive material in PVC matrix in presence of bis(2-ethyl hexyl) phthalate (BEP) as a plasticizer. The sensor showed a fast, stable, near Nernstian response for 1 × 10-2 –1 × 10-6 M NIM over the pH range 5 – 8 with a slope 55.6 ±0.5m V/decade and the response time is < 45 s. Selectivity coefficient data for some common ions show negligible interferences. The sensor was successfully applied for the determination of NIM in tablet and the results obtained are in good agreement with those obtained by the official method.
Resumo:
The fabrication and analytical applications of two types of potentiometric sensors for the determination of ketoconazole (KET) are described. The sensors are based on the use of KET-molybdophosphoric acid (MPA) ion pair as electroactive material. The fabricated sensors include both polymer membrane and carbon paste electrodes. Both sensors showed a linear, stable and near Nernstian slope of 57.8mV=decade and 55.2mV=decade for PVC membrane and carbon paste sensors respectively over a relatively wide range of KET concentration (1×10-2-5×10-5 and 1×10-2-1×10-6). The sensors showed a fast response time of <30 sec and <45 sec. A useful pH range of 3–6 was obtained for both types of sensors. A detection limit of 2.96 10 5M was obtained for PVC membrane sensor and 6.91 10 6M was obtained for carbon paste sensor. The proposed sensors proved to have a good selectivity for KET with respect to a large number of ions. The proposed sensors were successfully applied for the determination of KET in pharmaceutical formulations. The results obtained are in good agreement with the values obtained by the standard method.
Resumo:
The development of electrochemical sensors is currently one of the active areas of research in analytical chemistry.Voltammetric sensors as an important class of electrochemical sensors are extensively used in pharmaceutical applications.In voltammetric analysis,many active compounds in dosage forms,in contrast to excipients,can be readily oxidised or reduced at the electrode surface by applying a potential.Chemically modified electrodes have great significance in the electrochemical determination of pharmaceuticals.The modification of electrode results in efficient determination of electroactive species at very lower potential without any major interferences.The present study involves the fabrication of 8 voltammetric sensors for the drugs Metronidazole Benzoate, Sulfamethoxazole, Acyclovir, Pam Chloride , Trimethoprim , Tamsulosin Hydrochloride and Ceftriaxone Sodium.Two sensors were developed for the drug tamsulosin hydrochloride while one sensor each was developed for the other drugs.
Resumo:
The fabrication and electrochemical response characteristics of two novel potentiometric sensors for the selective determination of domperidone (DOM) are described. The two fabricated sensors incorporate DOM–PTA (phosphotungstic acid) ion pair as the electroactive material. The sensors include a PVC membrane sensor and a carbon paste sensor. The sensors showed a linear, stable, and near Nernstian slope of 56.5 and 57.8 mV/decade for PVC membrane and carbon paste sensors, respectively over a relatively wide range of DOM concentration (1.0 9 10-1–1.0 9 10-5 and 1.0 9 10-1–3.55 9 10-6 M). The response time of DOM–PTA membrane sensor was less than 25 s and that in the case of carbon paste sensor was less than 20 s.Auseful pH range of 4–6 was obtained for both types of sensors. A detection limit of 7.36 9 10-5 M was obtained for PVC membrane sensor and 1.0 9 10-6 M was obtained for carbon paste sensor. The proposed sensors showed very good selectivity toDOMin the presence of a large number of other interfering ions. The analytical application of the developed sensors in the determination of the drug in pharmaceutical formulations such as tablets was investigated. The results obtained are in good agreement with the values obtained by the standard method. The sensors were also applied for the determination ofDOMin real samples such as urine by the standard addition method.