8 resultados para Contexts of change and accountability

em Cochin University of Science


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Department of Applied Economics, Cochin University of Science And Technology.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Induction of growth in the primary marine fishing industry of Kerala is a sine gua Qgn for improving the economy of the fishermen, the state's domestic product as well as earning more foreign exchange for the country. The State Administration has been trying to instil growth into the industry eversince the output of the industry showed marked sign of decline (particularly after 1975). Significantly, it has attempted to strengthen the traditional sector, (which is considered to be the crucial sector of the primary marine fishing industry of the state) by introducing intermediate technology and by revamping the organisational structure of the industry. But it appears that the production system in the primary marine fishing industry of Kerala has been severely constrained by the existing technology, organisation of production and marketing institutions. Regeneration of growth in the industry calls forth an understanding of the 'process' of growth in the industry and the need to réorganise it with new technology, and new organisations. The present study is an attempt to unraval the process of growth in the primary marine fishing industry of Kerala since 1951

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The cumulative effects of global change, including climate change, increased population density and domestic waste disposal, effluent discharges from industrial processes, agriculture and aquaculture will likely continue and increases the process of eutrophication in estuarine environments. Eutrophication is one of the leading causes of degraded water quality, water column hypoxia/anoxia, harmful algal bloom (HAB) and loss of habitat and species diversity in the estuarine environment. The present study attempts to characterize the trophic condition of coastal estuary using a simple tool; trophic index (TRIX) based on a linear combination of the log of four state variables with supplementary index Efficiency Coefficient (Eff. Coeff.) as a discriminating tool. Numerically, the index TRIX is scaled from 0 to10, covering a wide range of trophic conditions from oligotrophic to eutrophic. Study area Kodungallur-Azhikode Estuary (KAE) was comparatively shallow in nature with average depth of 3.6±0.2 m. Dissolve oxygen regime in the water column was ranged from 4.7±1.3 mgL−1 in Station I to 5.9±1.4 mgL−1 in Station IV. The average nitrate-nitrogen (NO3-N) of KAE water was 470 mg m−3; values ranged from Av. 364.4 mg m−3 at Station II to Av. 626.6 mg m−3at Station VII. The mean ammonium-nitrogen (NH4 +-N) varied from 54.1 mg m−3 at Station VII to 101 mg m−3 at Station III. The average Chl-a for the seven stations of KAE was 6.42±3.91 mg m−3. Comparisons over different spatial and temporal scales in the KAE and study observed that, estuary experiencing high productivity by the influence of high degree of eutrophication; an annual average of 6.91 TRIX was noticed in the KAE and seasonal highest was observed during pre monsoon period (7.15) and lowest during post monsoon period (6.51). In the spatial scale station V showed high value 7.37 and comparatively low values in the station VI (6.93) and station VII (6.96) and which indicates eutrophication was predominant in land cover area with comparatively high water residence time. Eff. Coeff. values in the KAE ranges from −2.74 during monsoon period to the lowest of −1.98 in pre monsoon period. Present study revealed that trophic state of the estuary under severe stress and the restriction of autochthonous and allochthonous nutrient loading should be keystone in mitigate from eutrophication process

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The dynamic mechanical properties such as storage modulus, loss modulus and damping properties of blends of nylon copolymer (PA6,66) with ethylene propylene diene (EPDM) rubber was investigated with special reference to the effect of blend ratio and compatibilisation over a temperature range –100°C to 150°C at different frequencies. The effect of change in the composition of the polymer blends on tanδ was studied to understand the extent of polymer miscibility and damping characteristics. The loss tangent curve of the blends exhibited two transition peaks, corresponding to the glass transition temperature (Tg) of individual components indicating incompatibility of the blend systems. The morphology of the blends has been examined by using scanning electron microscopy. The Arrhenius relationship was used to calculate the activation energy for the glass transition of the blends. Finally, attempts have been made to compare the experimental data with theoretical models.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Among the large number of photothcrmal techniques available, photoacoustics assumes a very significant place because of its essential simplicity and the variety of applications it finds in science and technology. The photoacoustic (PA) effect is the generation of an acoustic signal when a sample, kept inside an enclosed volume, is irradiated by an intensity modulated beam of radiation. The radiation absorbed by the sample is converted into thermal waves by nonradiative de-excitation processes. The propagating thermal waves cause a corresponding expansion and contraction of the gas medium surrounding the sample, which in tum can be detected as sound waves by a sensitive microphone. These sound waves have the same frequency as the initial modulation frequency of light. Lock-in detection method enables one to have a sufficiently high signal to noise ratio for the detected signal. The PA signal amplitude depends on the optical absorption coefficient of the sample and its thermal properties. The PA signal phase is a function of the thermal diffusivity of the sample.Measurement of the PA amplitude and phase enables one to get valuable information about the thermal and optical properties of the sample. Since the PA signal depends on the optical and thennal properties of the sample, their variation will get reflected in the PA signal. Therefore, if the PA signal is collected from various points on a sample surface it will give a profile of the variations in the optical/thennal properties across the sample surface. Since the optical and thermal properties are affected by the presence of defects, interfaces, change of material etc. these will get reflected in the PA signal. By varying the modulation frequency, we can get information about the subsurface features also. This is the basic principle of PA imaging or PA depth profiling. It is a quickly expanding field with potential applications in thin film technology, chemical engineering, biology, medical diagnosis etc. Since it is a non-destructive method, PA imaging has added advantages over some of the other imaging techniques. A major part of the work presented in this thesis is concemed with the development of a PA imaging setup that can be used to detect the presence of surface and subsmface defects in solid samples.Determination of thermal transport properties such as thermal diffusivity, effusivity, conductivity and heat capacity of materials is another application of photothennal effect. There are various methods, depending on the nature of the sample, to determine these properties. However, there are only a few methods developed to determine all these properties simultaneously. Even though a few techniques to determine the above thermal properties individually for a coating can be found in literature, no technique is available for the simultaneous measurement of these parameters for a coating. We have developed a scanning photoacoustic technique that can be used to determine all the above thermal transport properties simultaneously in the case of opaque coatings such as paints. Another work that we have presented in this thesis is the determination of thermal effusivity of many bulk solids by a scanning photoacoustic technique. This is one of the very few methods developed to determine thermal effiisivity directly.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Nonlinear optics has been a rapidly growing field in recent decades since the invention of lasers. The systematic progress in the laser technology increases our efficiency in the generation and control of coherent optical radiations. Nonlinear optics is based on the study ofeffects and phenomena related to the interaction of intense coherent light radiation with matter. Compared to other light sources laser radiation can provide high directionality, high monochromaticiry, high brightness and high photon degeneracy. At such a very intense incident beam, the matter responds in a nonlinear manner to the incident radiation fields, which endows the media :1 characteristic to change the refractive index or absorption coe fflcient of the media or the wavelength, or the frequency of the incident electromagnetic waves. This thesis encompasses the fabrication of nonlinear optical devices based on semiconductor and metal nanostructures. The presented work focus on the experimental and theoretical discussions on nonlinear optical effects especially nonlinear absorption and refraction exhibitted by metal and semiconductor nanostructures

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Chemical sensors have growing interest in the determination of food additives, which are creating toxicity and may cause serious health concern, drugs and metal ions. A chemical sensor can be defined as a device that transforms chemical information, ranging from the concentration of a specific sample component to total composition analysis, into an analytically useful signal. The chemical information may be generated from a chemical reaction of the analyte or from a physical property of the system investigated. Two main steps involved in the functioning of a chemical sensor are recognition and transduction. Chemical sensors employ specific transduction techniques to yield analyte information. The most widely used techniques employed in chemical sensors are optical absorption, luminescence, redox potential etc. According to the operating principle of the transducer, chemical sensors may be classified as electrochemical sensors, optical sensors, mass sensitive sensors, heat sensitive sensors etc. Electrochemical sensors are devices that transform the effect of the electrochemical interaction between analyte and electrode into a useful signal. They are very widespread as they use simple instrumentation, very good sensitivity with wide linear concentration ranges, rapid analysis time and simultaneous determination of several analytes. These include voltammetric, potentiometric and amperometric sensors. Fluorescence sensing of chemical and biochemical analytes is an active area of research. Any phenomenon that results in a change of fluorescence intensity, anisotropy or lifetime can be used for sensing. The fluorophores are mixed with the analyte solution and excited at its corresponding wavelength. The change in fluorescence intensity (enhancement or quenching) is directly related to the concentration of the analyte. Fluorescence quenching refers to any process that decreases the fluorescence intensity of a sample. A variety of molecular rearrangements, energy transfer, ground-state complex formation and collisional quenching. Generally, fluorescence quenching can occur by two different mechanisms, dynamic quenching and static quenching. The thesis presents the development of voltammetric and fluorescent sensors for the analysis of pharmaceuticals, food additives metal ions. The developed sensors were successfully applied for the determination of analytes in real samples. Chemical sensors have multidisciplinary applications. The development and application of voltammetric and optical sensors continue to be an exciting and expanding area of research in analytical chemistry. The synthesis of biocompatible fluorophores and their use in clinical analysis, and the development of disposable sensors for clinical analysis is still a challenging task. The ability to make sensitive and selective measurements and the requirement of less expensive equipment make electrochemical and fluorescence based sensors attractive.