14 resultados para CHROMIUM IONS
em Cochin University of Science
Resumo:
In this study Fabrication of Potentiometric sensors for the determination of certain metal ions, presents the synthesis and characterization of seven ionophores, their use in the fabrication of potentiometric sensors and the results and discussion of fourteen sensors developed for the determination of five transition metal ions. As part of the present investigations a total of fourteen potentiometric sensors have been developed and fabricated. A three fold approach has been taken in developing he sensors, PVC plasticized membrane sensor, carbon paste electrode and chemically modified carbon paste electrode. All the sensors are highly useful in the determination of metal ions such as manganese, nickel, copper, mercury and lead. A through analytical study has been carried out with respect to each other developed. Based on these studies, optimum conditions have been developed for the quantitative determinations of the selected metal ions using the sensors. Systematic application studies have also been carried out for all the developed sensors and the results revealed that the presently developed sensors are far superior than most of the sensors reported.
Resumo:
A new PVC membrane sensor, which is highly selective towards Ni (II) ions, has been developed using a thiophene-derivative Schiff base as the ionophore. The best performance was exhibited by the membrane having the composition percentage ratio of 5:3:61:31 (ionophore:NaTPB:DBP:PVC) (w=w), where NaTPB is the anion excluder, sodium tetraphenylborate and DBP is the plasticizing agent (dibutyl phthalate). The membrane exhibited a good Nernstian response for nickel ions over the concentration range of 1.0 10 1– 5.0 10 6M (limit of detection is 1.8 10 6 M) with a slope of 29.5 1.0mV per decade of activity. It has a fast response time of<20 s and can be used for a period of 4 months with good reproducibility. The sensor is suitable for use in aqueous solutions of a wide pH range of 3.2–7.9. The sensor shows high selectivity to nickel ions over a large number of mono-, bi- and trivalent cations. It has been successfully used as an indicator electrode in the potentiometric titration of nickel ions against EDTA and also for direct determination of nickel content in real samples – wastewater samples from electroplating industries and Indian chocolates.
Resumo:
A spectrophotometric method employing 2-hydroxybenzaldiminoglycine (HBIG) is proposed for the determination of chromium(III). The results of the determinations are compared with the standard diphenyl carbazide method. The presently developed method is direct, simple, rapid, selective, sensitive and precise.
Resumo:
A new PVC membrane sensor, which is highly selective towards Ni (II) ions, has been developed using a thiophene-derivative Schiff base as the ionophore. The best performance was exhibited by the membrane having the composition percentage ratio of 5:3:61:31 (ionophore:NaTPB:DBP:PVC) (w=w), where NaTPB is the anion excluder, sodium tetraphenylborate and DBP is the plasticizing agent (dibutyl phthalate). The membrane exhibited a good Nernstian response for nickel ions over the concentration range of 1.0 10 1– 5.0 10 6M (limit of detection is 1.8 10 6 M) with a slope of 29.5 1.0mV per decade of activity. It has a fast response time of<20 s and can be used for a period of 4 months with good reproducibility. The sensor is suitable for use in aqueous solutions of a wide pH range of 3.2–7.9. The sensor shows high selectivity to nickel ions over a large number of mono-, bi- and trivalent cations. It has been successfully used as an indicator electrode in the potentiometric titration of nickel ions against EDTA and also for direct determination of nickel content in real samples – wastewater samples from electroplating industries and Indian chocolates.
Resumo:
The effect of chromium doping on methylene blue sensitized Poly (vinyl alcohol)/Acrylamide was carried out by varying the ratios of Ammonium dichromate and methylene blue. In the case of films without ammonium dichromate, the diffraction efficiency was found to decrease on storage. On chromium doping the storage life was improved. Interestingly, a self-enhancement in efficiency was observed for a particular ratio of methylene blue and ammonium dichromate.
Resumo:
In this work polymers belonging to polyaniline and polyaniline doped with camphor sulphonic acid are synthesised. Cobalt phthalocyanine is an interesting candidate belonging to the tetramers. Studies on the composites containing cobalt phthalocyanine tetramer and polyaniline doped with camphor sulphonic acid for various concentration are also undertaken in order to understand the mechanism. RF plasma polymerised aniline and furfural are prepared. The structural and electrical properties are evaluated. The bombardment of swift heavy ions of these films are carried out and the effect of irradiation on their properties is also investigated.
Resumo:
Surface acidity of phosphate modified La2O3,CeO2 and SnO2 has been estimated by titrimetric Method using Hammett Indicators.Mixed Oxides of tin and lanthanum have also been prepared and subjected to phosphate modification.Surface characterizartion of the samples has been carried out using XRD, surface area,thermal analysis and IR spectroscopy. Phosphate content in the samples has been chemically estimated. The catalytic activity for benzylation and esterification reaction has also been investigated.
Resumo:
Various compositions of chromium manganese ferrospinels were tested as catalysts for the vapour phase alkylation of aniline with methanol. The samples were prepared by room temperature co-precipitation technique and characterized by various physico-chemical methods. The acidity–basicity determination revealed that the samples possess greater amount of basic sites than acidic sites. All the ferrite samples proved to be selective and active for N-monoalkylation of aniline leading to N-methyl aniline; Cr0.6Mn0.4Fe2O4, Cr0.8Mn0.2Fe2O4 and CrFe2O4 exhibited cent percent selectivity for N-methyl aniline. Neither C-alkylated products nor any other side products were detected for all catalyst samples. The catalytic activity of the samples studied in this reaction is related to their acid–base properties and also on the cation distribution. Under the optimized reaction conditions all the systems showed constant activity for a long duration.
Resumo:
The design and development of a cost-effective, simple, sensitive and portable LED based fiber optic evanescent wave sensor for simultaneously detecting trace amounts of chromium and nitrite in water are presented. In order to obtain the desired performance, the middle portions of two multimode plastic clad silica fibers are unclad and are used as the sensing elements in the two arms of the sensor. Each of the sensor arms is sourced by separate super bright green LEDs, which are modulated in a time-sharing manner and a single photo detector is employed for detecting these light signals. The performance and characteristics of this system clearly establish the usefulness of the technique for detecting very low concentrations of the dissolved contaminants.
Resumo:
In many fields such as earth science biology, environment and electronics, the knowledge about elemental distributions and chemical speciation is important. The determination of metal levels especially the toxic ones both in the environment and in biological materials are increasingly demanded by the society.Ion selective sensors have become one of the most effective ad powerful means for analytical scientists for the trace level monitoring of metal ions. The wide range of applications ,low material requirements and simplicity of analytical procedure have not only brought ion-selective electrodes in to the lime light of analytical chemistry,but have promoted their use as tools for physiologists,medical researchers,biologists,geologists,environmental protection specialists etc.Potentiometric ion-selective sensors have been developed for the determination of lanthanide ions such as La3+,Nd3+,Pr3+,Sm3+, and Gd3+.The sensors fabricated include both PVC membrane sensor and chemically modified carbon paste sensor. A set of 10 sensors have been developed. The response parameters of all the sensors have been studied and the sensors were applied as an indicator electrode in the potentiometric titration and for the determination of metal ions in real samples.
Resumo:
This thesis deals with the studies on the synthesis and characterisation of the complexes of embelin with manganese (II), cobalt(II), nickel (II), copper (II), zinc (II), cadmium (II), chromium (III), iron (III) lanthanum(III), praseodymium (III) neodymium (III) Samarium (III), gadolinium (III) dysprosium (III), yttrium (III) thorium (IV) and uranium (VI). Elemental analysis as well as spectral, thermal and magnetic data were used to ascertain the composition of the complexes and to establish the structures of the metal complexes. Wherever possible, the electronic spectra and magnetic data were used to predict the stereochemistry of the complexes.The thesis is divided into four chapters.
Resumo:
The objective of the present work is to improve the textural and structural properties of cerium oxide by the incorporation of transition metals as well as sulphate ions. We have incorporated tungsten, molybdenum and chromium oxide into pure as well as sulphated cerium oxide and the catalytic systems thus prepared were characterised using various techniques. lndustrially important reactions such as acetalization and deacetalization, oxidative dehydrogenation of ethylbenzene, MTBE synthesis and Beckmann rearrangement of cinnamaldoxime and salicylaldoxime have been selected for the measurement of the catalytic activity of the systems. The work is presented in eight chapters
Resumo:
Polyaniline thin films prepared by RF plasma polymerisation were irradiated with 92MeV Si ions for various fluences of 1 1011, 1 1012 and 1 1013 ions/cm2. FTIR and UV–vis–NIR measurements were carried out on the pristine and Si ion irradiated polyaniline thin films for structural evaluation and optical band gap determination. The effect of swift heavy ions on the structural and optical properties of plasma-polymerised aniline thin film is investigated. Their properties are compared with that of the pristine sample. The FTIR spectrum indicates that the structure of the irradiated sample is altered. The optical studies show that the band gap of irradiated thin film has been considerably modified. This has been attributed to the rearrangement in the ring structure and the formation of CRC terminals. This results in extended conjugated structure causing reduction in optical band gap