69 resultados para Compact fluorescent lamp
Resumo:
A compact coplanar waveguide (CPW) fed uniplanar antenna for Quad-band applications is presented. The Quad-band operation is realized by imposing various current paths in a modified T-shaped radiating element. The antenna covers GSM 900, DCS 1800, IEEE802.11.a, IEEE802.11.b and HiperLAN-2 bands and exhibits good radiation characteristics. This low profile antenna has a dimension of 32mm×31mmwhen printed on a substrate of dielectric constant 4.4 and height 1.6mm. Details of design with experimental and simulated results are presented
Resumo:
A method for simultaneously enhancing the bandwidth and reducing the size of microstrip antennas (MSAs) using a modified ground plane (GP) has been proposed with design formulas. A combshaped truncated GP is used for this purpose. This method provides an overall compactness up to 85% for proximity-coupled MSAs in the frequency range of 900 MHz–5.5 GHz with an improvement inbandwidth up to seven times when compared with the conventional ones
Resumo:
This paper presents the design and development of a compact CPW fed quad band antenna. This low profile antenna has a dimension of 32mmx31mm when printed on a substrate of dielectric constant 4.4 and height 1.6mm. The antenna covers GSM 900, DCS 1800, IEEE802.11.a, IEEE802.11.b and HiperLAN2 bands. The antenna exhibits good radiation characteristics with moderate gain
Resumo:
In this paper the design issues of compact genetic microstrip antennas for mobile applications has been investigated. The antennas designed using Genetic Algorithms (GA) have an arbitrary shape and occupies less area (compact) compared to the traditionally designed antenna for the same frequency but with poor performance. An attempt has been made to improve the performance of the genetic microstrip antenna by optimizing the ground plane (GP) to have a fish bone like structure. The genetic antenna with the GP optimized is even better compared to the traditional and the genetic antenna.
Resumo:
Multimodal imaging agents that combine magnetic and fluorescent imaging capabilities are desirable for the high spatial and temporal resolution. In the present work, we report the synthesis of multifunctional fluorescent ferrofluids using iron oxide as the magnetic core and rhodamine B as fluorochrome shell. The core–shell structure was designed in such a way that fluorescence quenching due to the inner magnetic core was minimized by an intermediate layer of silica. The intermediate passive layer of silica was realized by a novel method which involves the esterification reaction between the epoxy group of prehydrolysed 3-Glyidoxypropyltrimethoxysilane and the surfactant over iron oxide. The as-synthesized ferrofluids have a high saturation magnetization in the range of 62–65 emu/g and were found to emit light of wavelength 640 nm ( excitation = 446 nm). Time resolved life time decay analysis showed a bi-exponential decay pattern with an increase in the decay life time in the presence of intermediate silica layer. Cytotoxicity studies confirmed the cell viability of these materials. The in vitro MRI imaging illustrated a high contrast when these multimodal nano probes were employed and the R2 relaxivity of these ∗Author to whom correspondence should be addressed. Email: smissmis@gmail.com sample was found to be 334 mM−1s−1 which reveals its high potential as a T2 contrast enhancing agent
Resumo:
Earlier studies on measurement of customer satisfaction are based on either transaction specific or overall approaches. The transaction specific approach evaluates customer satisfaction with single components in the whole purchase process but the overall satisfaction was based on all the encounters or experiences to the customer throughout the purchase process. Consumers will comment on particular events of their purchase process when asked about transaction-specific satisfaction and they will comment their overall impression and general experiences in overall satisfaction (Bitner & Hubbert 1994) Through a critical review on the literature, it has been identified a new approaches to customer satisfaction, say, cumulative approaches that can be more useful than overall and transaction specific approaches for strategic decision making (Fornell et al 1996). The cumulative approach to customer satisfaction doesn’t study earlier due to the difficulty in operationalization of the concept. But the influencers of customer satisfaction are context specific and the prevailing models doesn’t give the sources of variations in the satisfaction, the importance of cumulative approaches to customer satisfaction has emerges that lights to a new research. The current study has focused to explore the influencers of overall customer satisfaction to form individual elements that can be used to identify the cumulative customer satisfaction.
Resumo:
The main objective of this thesis is to develop a compact chipless RFID tag with high data encoding capacity. The design and development of chipless RFID tag based on multiresonator and multiscatterer methods are presented first. An RFID tag using using SIR capable of 79bits is proposed. The thesis also deals with some of the properties of SIR like harmonic separation, independent control on resonant modes and the capability to change the electrical length. A chipless RFID reader working in a frequency band of 2.36GHz to 2.54GHz has been designed to show the feasibility of the RFID system. For a practical system, a new approach based on UWB Impulse Radar (UWB IR) technology is employed and the decoding methods from noisy backscattered signal are successfully demonstrated. The thesis also proposes a simple calibration procedure, which is able to decode the backscattered signal up to a distance of 80cm with 1mW output power.
Resumo:
Division of Electronics Engineering
Resumo:
Chemical sensors have growing interest in the determination of food additives, which are creating toxicity and may cause serious health concern, drugs and metal ions. A chemical sensor can be defined as a device that transforms chemical information, ranging from the concentration of a specific sample component to total composition analysis, into an analytically useful signal. The chemical information may be generated from a chemical reaction of the analyte or from a physical property of the system investigated. Two main steps involved in the functioning of a chemical sensor are recognition and transduction. Chemical sensors employ specific transduction techniques to yield analyte information. The most widely used techniques employed in chemical sensors are optical absorption, luminescence, redox potential etc. According to the operating principle of the transducer, chemical sensors may be classified as electrochemical sensors, optical sensors, mass sensitive sensors, heat sensitive sensors etc. Electrochemical sensors are devices that transform the effect of the electrochemical interaction between analyte and electrode into a useful signal. They are very widespread as they use simple instrumentation, very good sensitivity with wide linear concentration ranges, rapid analysis time and simultaneous determination of several analytes. These include voltammetric, potentiometric and amperometric sensors. Fluorescence sensing of chemical and biochemical analytes is an active area of research. Any phenomenon that results in a change of fluorescence intensity, anisotropy or lifetime can be used for sensing. The fluorophores are mixed with the analyte solution and excited at its corresponding wavelength. The change in fluorescence intensity (enhancement or quenching) is directly related to the concentration of the analyte. Fluorescence quenching refers to any process that decreases the fluorescence intensity of a sample. A variety of molecular rearrangements, energy transfer, ground-state complex formation and collisional quenching. Generally, fluorescence quenching can occur by two different mechanisms, dynamic quenching and static quenching. The thesis presents the development of voltammetric and fluorescent sensors for the analysis of pharmaceuticals, food additives metal ions. The developed sensors were successfully applied for the determination of analytes in real samples. Chemical sensors have multidisciplinary applications. The development and application of voltammetric and optical sensors continue to be an exciting and expanding area of research in analytical chemistry. The synthesis of biocompatible fluorophores and their use in clinical analysis, and the development of disposable sensors for clinical analysis is still a challenging task. The ability to make sensitive and selective measurements and the requirement of less expensive equipment make electrochemical and fluorescence based sensors attractive.