15 resultados para sinus node, pacemaking, 3D anatomical model, arrhythmias

em Université de Montréal, Canada


Relevância:

100.00% 100.00%

Publicador:

Resumo:

There are many ways to generate geometrical models for numerical simulation, and most of them start with a segmentation step to extract the boundaries of the regions of interest. This paper presents an algorithm to generate a patient-specific three-dimensional geometric model, based on a tetrahedral mesh, without an initial extraction of contours from the volumetric data. Using the information directly available in the data, such as gray levels, we built a metric to drive a mesh adaptation process. The metric is used to specify the size and orientation of the tetrahedral elements everywhere in the mesh. Our method, which produces anisotropic meshes, gives good results with synthetic and real MRI data. The resulting model quality has been evaluated qualitatively and quantitatively by comparing it with an analytical solution and with a segmentation made by an expert. Results show that our method gives, in 90% of the cases, as good or better meshes as a similar isotropic method, based on the accuracy of the volume reconstruction for a given mesh size. Moreover, a comparison of the Hausdorff distances between adapted meshes of both methods and ground-truth volumes shows that our method decreases reconstruction errors faster. Copyright © 2015 John Wiley & Sons, Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

L'activité électrique du coeur est initiée par la génération spontanée de potentiels d'action venant des cellules pacemaker du noeud sinusal (SN). Toute dysfonction au niveau de cette région entraîne une instabilité électrique du coeur. La majorité des patients souffrant d'un noeud sinusal déficient nécessitent l'implantation chirurgicale d'un pacemaker électronique; cependant, les limitations de cette approche incitent à la recherche d'une alternative thérapeutique. La base moléculaire des courants ioniques jouant un rôle crucial dans l'activité du noeud sinusal sont de plus en plus connues. Une composante importante de l'activité des cellules pacemakers semble être le canal HCN, responsable du courant pacemaker If. Le facteur T-box 3 (Tbx3), un facteur de transcription conservé durant le processus de l'évolution, est nécessaire au développement du système de conduction cardiaque. De précédentes études ont démontré que dans différentes lignées cellulaires le Phorbol 12-myristate 13-acetate (PMA) active l'expression du gène codant Tbx3 via des réactions en cascade partant de la protéine kinase C (PKC). L'objectif principal de cette étude est de tester si le PMA peut augmenter la fréquence et la synchronisation de l'activité spontanée du pacemaker biologique en culture. Plus précisément, nous avons étudié les effets de l'exposition chronique au PMA sur l'expression du facteur de transcription Tbx3, sur HCN4 et l'activité spontanée chez des monocouches de culture de myocytes ventriculaires de rats néonataux (MVRN). Nos résultats démontrent que le PMA augmente significativement le facteur transcription de Tbx3 et l'expression ARNm de HCN4, favorisant ainsi l'augmentation du rythme et de la stabilité de l'activité autonome. De plus, une diminution significative de la vitesse de conduction a été relevée et est attribuée à la diminution du couplage intercellulaire. La diminution de la vitesse de conduction pourrait expliquer l'effet négatif du PMA sur la synchronisation de l'activité autonome du pacemaker biologique. Ces résultats ont été confirmés par un modèle mathématique multicellulaire suggérant que des fréquences et résistances intercellulaires plus élevée pourraient induire une activité plus stable et moins synchrone. Cette étude amène de nouvelles connaissances très importantes destinées à la production d'un pacemaker biologique efficient et robuste.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Le système nerveux autonome cardiaque est devenu une cible dans les thérapies ablatives de la fibrillation auriculaire. Nous avons étudié les voies de communication et la fonction des plexus ganglionnaires (PG) de l'oreillette gauche (PGOG) afin de clarifier la validité physiopathologique des méthodes de détection et des thérapies impliquant ces groupes de neuronnes. Méthodes: Vingt-deux chiens ont subi une double thoracotomie et ont été instrumentés avec des plaques auriculaires épidcardiques de multiélectrodes. Une stimulation électrique (2 mA, 15 Hz) des PGOG a été réalisée à l'état basal et successivement après: 1) une décentralisation vagale, 2) l'ablation par radiofréquence des plexus péri-aortiques et de la veine cave supérieure (Ao/VCS) et 3) l'ablation du PG de l'oreillette droite (PGOD). Ces procédures de dénervation ont été réalisées suivant une séquence antérograde (n = 17) ou rétrograde (n = 5). Résultats: Chez 17 des 22 animaux, la stimulation des PGOG a induit une bradycardie sinusale (149 ± 34 bpm vs 136 ± 28 bpm, p < 0.002) et des changements de repolarization (ΔREPOL) auriculaires isointégrales. Dans le groupe des ablations antérogrades, les réponses aux stimulations vagales ont été supprimées suite à la décentralisation vagale chez un seul animal, par l'ablation des plexus Ao/VCS dans 4 cas et par l'ablation du PGOG dans 5 autres animaux. Des changements ont persisté tout au long chez 2 chiens. La valeur de surface des ΔREPOL a diminué avec les dénervations séquentielles, passant de 365 ± 252 mm2 en basale à 53 ± 106 mm2 après l'ablation du PGOD (p < 0.03). Dans le groupe de dénervation rétrograde, les changements de repolarisation et chronotropiques ont été supprimés suite à l'ablation du PGOD chez deux chiens et suite à l'ablation Ao/VCS chez trois. La valeur de surface du ΔREPOL a aussi diminué après l'ablation du PGOD (269±144mm2 vs 124±158mm2, p<0.05). Conclusion: Les PGOD sont identifiables en préablation par la réponse bradycardique à la stimulation directe dans la plupart des cas. Le PGOD semble former la principale, mais non la seule, voie de communication avec le nœud sinusal. Ces résultats pourraient avoir des implications dans le traitement de la FA par méthodes ablatives.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

La fibrillation auriculaire, l'arythmie la plus fréquente en clinique, affecte 2.3 millions de patients en Amérique du Nord. Pour en étudier les mécanismes et les thérapies potentielles, des modèles animaux de fibrillation auriculaire ont été développés. La cartographie électrique épicardique à haute densité est une technique expérimentale bien établie pour suivre in vivo l'activité des oreillettes en réponse à une stimulation électrique, à du remodelage, à des arythmies ou à une modulation du système nerveux autonome. Dans les régions qui ne sont pas accessibles par cartographie épicardique, la cartographie endocardique sans contact réalisée à l'aide d'un cathéter en forme de ballon pourrait apporter une description plus complète de l'activité auriculaire. Dans cette étude, une expérience chez le chien a été conçue et analysée. Une reconstruction électro-anatomique, une cartographie épicardique (103 électrodes), une cartographie endocardique sans contact (2048 électrodes virtuelles calculées à partir un cathéter en forme de ballon avec 64 canaux) et des enregistrements endocardiques avec contact direct ont été réalisés simultanément. Les systèmes d'enregistrement ont été également simulés dans un modèle mathématique d'une oreillette droite de chien. Dans les simulations et les expériences (après la suppression du nœud atrio-ventriculaire), des cartes d'activation ont été calculées pendant le rythme sinusal. La repolarisation a été évaluée en mesurant l'aire sous l'onde T auriculaire (ATa) qui est un marqueur de gradient de repolarisation. Les résultats montrent un coefficient de corrélation épicardique-endocardique de 0.8 (expérience) and 0.96 (simulation) entre les cartes d'activation, et un coefficient de corrélation de 0.57 (expérience) and 0.92 (simulation) entre les valeurs de ATa. La cartographie endocardique sans contact apparait comme un instrument expérimental utile pour extraire de l'information en dehors des régions couvertes par les plaques d'enregistrement épicardique.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Présentation: Cet article a été publié dans le journal : Computerised medical imaging and graphics (CMIG). Le but de cet article est de recaler les vertèbres extraites à partir d’images RM avec des vertèbres extraites à partir d’images RX pour des patients scoliotiques, en tenant compte des déformations non-rigides due au changement de posture entre ces deux modalités. À ces fins, une méthode de recalage à l’aide d’un modèle articulé est proposée. Cette méthode a été comparée avec un recalage rigide en calculant l’erreur sur des points de repère, ainsi qu’en calculant la différence entre l’angle de Cobb avant et après recalage. Une validation additionelle de la méthode de recalage présentée ici se trouve dans l’annexe A. Ce travail servira de première étape dans la fusion des images RM, RX et TP du tronc complet. Donc, cet article vérifie l’hypothèse 1 décrite dans la section 3.2.1.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper presents a method based on articulated models for the registration of spine data extracted from multimodal medical images of patients with scoliosis. With the ultimate aim being the development of a complete geometrical model of the torso of a scoliotic patient, this work presents a method for the registration of vertebral column data using 3D magnetic resonance images (MRI) acquired in prone position and X-ray data acquired in standing position for five patients with scoliosis. The 3D shape of the vertebrae is estimated from both image modalities for each patient, and an articulated model is used in order to calculate intervertebral transformations required in order to align the vertebrae between both postures. Euclidean distances between anatomical landmarks are calculated in order to assess multimodal registration error. Results show a decrease in the Euclidean distance using the proposed method compared to rigid registration and more physically realistic vertebrae deformations compared to thin-plate-spline (TPS) registration thus improving alignment.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

One of the major concerns of scoliosis patients undergoing surgical treatment is the aesthetic aspect of the surgery outcome. It would be useful to predict the postoperative appearance of the patient trunk in the course of a surgery planning process in order to take into account the expectations of the patient. In this paper, we propose to use least squares support vector regression for the prediction of the postoperative trunk 3D shape after spine surgery for adolescent idiopathic scoliosis. Five dimensionality reduction techniques used in conjunction with the support vector machine are compared. The methods are evaluated in terms of their accuracy, based on the leave-one-out cross-validation performed on a database of 141 cases. The results indicate that the 3D shape predictions using a dimensionality reduction obtained by simultaneous decomposition of the predictors and response variables have the best accuracy.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper provides an overview of work done in recent years by our research group to fuse multimodal images of the trunk of patients with Adolescent Idiopathic Scoliosis (AIS) treated at Sainte-Justine University Hospital Center (CHU). We first describe our surface acquisition system and introduce a set of clinical measurements (indices) based on the trunk's external shape, to quantify its degree of asymmetry. We then describe our 3D reconstruction system of the spine and rib cage from biplanar radiographs and present our methodology for multimodal fusion of MRI, X-ray and external surface images of the trunk We finally present a physical model of the human trunk including bone and soft tissue for the simulation of the surgical outcome on the external trunk shape in AIS.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Réalisée en cotutelle avec l'Unité de Formation à la Recherche Lettres Arts et Sciences Humaines - Université Nice-Sophia Antipolis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This thesis was created in Word and converted to PDF using Mac OS X 10.7.5 Quartz PDFContext.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Ce mémoire s'intéresse à la reconstruction d'un modèle 3D à partir de plusieurs images. Le modèle 3D est élaboré avec une représentation hiérarchique de voxels sous la forme d'un octree. Un cube englobant le modèle 3D est calculé à partir de la position des caméras. Ce cube contient les voxels et il définit la position de caméras virtuelles. Le modèle 3D est initialisé par une enveloppe convexe basée sur la couleur uniforme du fond des images. Cette enveloppe permet de creuser la périphérie du modèle 3D. Ensuite un coût pondéré est calculé pour évaluer la qualité de chaque voxel à faire partie de la surface de l'objet. Ce coût tient compte de la similarité des pixels provenant de chaque image associée à la caméra virtuelle. Finalement et pour chacune des caméras virtuelles, une surface est calculée basée sur le coût en utilisant la méthode de SGM. La méthode SGM tient compte du voisinage lors du calcul de profondeur et ce mémoire présente une variation de la méthode pour tenir compte des voxels précédemment exclus du modèle par l'étape d'initialisation ou de creusage par une autre surface. Par la suite, les surfaces calculées sont utilisées pour creuser et finaliser le modèle 3D. Ce mémoire présente une combinaison innovante d'étapes permettant de créer un modèle 3D basé sur un ensemble d'images existant ou encore sur une suite d'images capturées en série pouvant mener à la création d'un modèle 3D en temps réel.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Le foie est un organe vital ayant une capacité de régénération exceptionnelle et un rôle crucial dans le fonctionnement de l’organisme. L’évaluation du volume du foie est un outil important pouvant être utilisé comme marqueur biologique de sévérité de maladies hépatiques. La volumétrie du foie est indiquée avant les hépatectomies majeures, l’embolisation de la veine porte et la transplantation. La méthode la plus répandue sur la base d'examens de tomodensitométrie (TDM) et d'imagerie par résonance magnétique (IRM) consiste à délimiter le contour du foie sur plusieurs coupes consécutives, un processus appelé la «segmentation». Nous présentons la conception et la stratégie de validation pour une méthode de segmentation semi-automatisée développée à notre institution. Notre méthode représente une approche basée sur un modèle utilisant l’interpolation variationnelle de forme ainsi que l’optimisation de maillages de Laplace. La méthode a été conçue afin d’être compatible avec la TDM ainsi que l' IRM. Nous avons évalué la répétabilité, la fiabilité ainsi que l’efficacité de notre méthode semi-automatisée de segmentation avec deux études transversales conçues rétrospectivement. Les résultats de nos études de validation suggèrent que la méthode de segmentation confère une fiabilité et répétabilité comparables à la segmentation manuelle. De plus, cette méthode diminue de façon significative le temps d’interaction, la rendant ainsi adaptée à la pratique clinique courante. D’autres études pourraient incorporer la volumétrie afin de déterminer des marqueurs biologiques de maladie hépatique basés sur le volume tels que la présence de stéatose, de fer, ou encore la mesure de fibrose par unité de volume.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Scoliosis is a 3D deformity of the spine and rib cage. Extensive validation of 3D reconstruction methods of the spine from biplanar radiography has already been published. In this article, we propose a novel method to reconstruct the rib cage, using the same biplanar views as for the 3D reconstruction of the spine, to allow clinical assessment of whole trunk deformities. This technique uses a semi-automatic segmentation of the ribs in the postero-anterior X-ray view and an interactive segmentation of partial rib edges in the lateral view. The rib midlines are automatically extracted in 2D and reconstructed in 3D using the epipolar geometry. For the ribs not visible in the lateral view, the method predicts their 3D shape. The accuracy of the proposed method has been assessed using data obtained from a synthetic bone model as a gold standard and has also been evaluated using data of real patients with scoliotic deformities. Results show that the reconstructed ribs enable a reliable evaluation of the rib axial rotation, which will allow a 3D clinical assessment of the spine and rib cage deformities.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

La spectrométrie de masse mesure la masse des ions selon leur rapport masse sur charge. Cette technique est employée dans plusieurs domaines et peut analyser des mélanges complexes. L’imagerie par spectrométrie de masse (Imaging Mass Spectrometry en anglais, IMS), une branche de la spectrométrie de masse, permet l’analyse des ions sur une surface, tout en conservant l’organisation spatiale des ions détectés. Jusqu’à présent, les échantillons les plus étudiés en IMS sont des sections tissulaires végétales ou animales. Parmi les molécules couramment analysées par l’IMS, les lipides ont suscité beaucoup d'intérêt. Les lipides sont impliqués dans les maladies et le fonctionnement normal des cellules; ils forment la membrane cellulaire et ont plusieurs rôles, comme celui de réguler des événements cellulaires. Considérant l’implication des lipides dans la biologie et la capacité du MALDI IMS à les analyser, nous avons développé des stratégies analytiques pour la manipulation des échantillons et l’analyse de larges ensembles de données lipidiques. La dégradation des lipides est très importante dans l’industrie alimentaire. De la même façon, les lipides des sections tissulaires risquent de se dégrader. Leurs produits de dégradation peuvent donc introduire des artefacts dans l’analyse IMS ainsi que la perte d’espèces lipidiques pouvant nuire à la précision des mesures d’abondance. Puisque les lipides oxydés sont aussi des médiateurs importants dans le développement de plusieurs maladies, leur réelle préservation devient donc critique. Dans les études multi-institutionnelles où les échantillons sont souvent transportés d’un emplacement à l’autre, des protocoles adaptés et validés, et des mesures de dégradation sont nécessaires. Nos principaux résultats sont les suivants : un accroissement en fonction du temps des phospholipides oxydés et des lysophospholipides dans des conditions ambiantes, une diminution de la présence des lipides ayant des acides gras insaturés et un effet inhibitoire sur ses phénomènes de la conservation des sections au froid sous N2. A température et atmosphère ambiantes, les phospholipides sont oxydés sur une échelle de temps typique d’une préparation IMS normale (~30 minutes). Les phospholipides sont aussi décomposés en lysophospholipides sur une échelle de temps de plusieurs jours. La validation d’une méthode de manipulation d’échantillon est d’autant plus importante lorsqu’il s’agit d’analyser un plus grand nombre d’échantillons. L’athérosclérose est une maladie cardiovasculaire induite par l’accumulation de matériel cellulaire sur la paroi artérielle. Puisque l’athérosclérose est un phénomène en trois dimension (3D), l'IMS 3D en série devient donc utile, d'une part, car elle a la capacité à localiser les molécules sur la longueur totale d’une plaque athéromateuse et, d'autre part, car elle peut identifier des mécanismes moléculaires du développement ou de la rupture des plaques. l'IMS 3D en série fait face à certains défis spécifiques, dont beaucoup se rapportent simplement à la reconstruction en 3D et à l’interprétation de la reconstruction moléculaire en temps réel. En tenant compte de ces objectifs et en utilisant l’IMS des lipides pour l’étude des plaques d’athérosclérose d’une carotide humaine et d’un modèle murin d’athérosclérose, nous avons élaboré des méthodes «open-source» pour la reconstruction des données de l’IMS en 3D. Notre méthodologie fournit un moyen d’obtenir des visualisations de haute qualité et démontre une stratégie pour l’interprétation rapide des données de l’IMS 3D par la segmentation multivariée. L’analyse d’aortes d’un modèle murin a été le point de départ pour le développement des méthodes car ce sont des échantillons mieux contrôlés. En corrélant les données acquises en mode d’ionisation positive et négative, l’IMS en 3D a permis de démontrer une accumulation des phospholipides dans les sinus aortiques. De plus, l’IMS par AgLDI a mis en évidence une localisation différentielle des acides gras libres, du cholestérol, des esters du cholestérol et des triglycérides. La segmentation multivariée des signaux lipidiques suite à l’analyse par IMS d’une carotide humaine démontre une histologie moléculaire corrélée avec le degré de sténose de l’artère. Ces recherches aident à mieux comprendre la complexité biologique de l’athérosclérose et peuvent possiblement prédire le développement de certains cas cliniques. La métastase au foie du cancer colorectal (Colorectal cancer liver metastasis en anglais, CRCLM) est la maladie métastatique du cancer colorectal primaire, un des cancers le plus fréquent au monde. L’évaluation et le pronostic des tumeurs CRCLM sont effectués avec l’histopathologie avec une marge d’erreur. Nous avons utilisé l’IMS des lipides pour identifier les compartiments histologiques du CRCLM et extraire leurs signatures lipidiques. En exploitant ces signatures moléculaires, nous avons pu déterminer un score histopathologique quantitatif et objectif et qui corrèle avec le pronostic. De plus, par la dissection des signatures lipidiques, nous avons identifié des espèces lipidiques individuelles qui sont discriminants des différentes histologies du CRCLM et qui peuvent potentiellement être utilisées comme des biomarqueurs pour la détermination de la réponse à la thérapie. Plus spécifiquement, nous avons trouvé une série de plasmalogènes et sphingolipides qui permettent de distinguer deux différents types de nécrose (infarct-like necrosis et usual necrosis en anglais, ILN et UN, respectivement). L’ILN est associé avec la réponse aux traitements chimiothérapiques, alors que l’UN est associé au fonctionnement normal de la tumeur.