3 resultados para proportional loading

em Université de Montréal, Canada


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a new model of voter behaviour under methods of proportional representation (PR). We abstract away from rounding, and assume that a party securing k percent of the vote wins exactly k percent of the available seats. Under this assumption PR is not manipulable by any voter aiming at maximisation of the number of seats in the parliament of her most preferred party. However in this paper we assume that voters are concerned, first and foremost, with the distribution of power in the post-election parliament. We show that, irrespective of which positional scoring rule is adopted, there will always exist circumstances where a voter would have an incentive to vote insincerely. We demonstrate that a voter’s attitude toward uncertainty can influence her incentives to make an insincere vote. Finally, we show that the introduction of a threshold - a rule that a party must secure at least a certain percentage of the vote in order to reach parliament - creates new opportunities for strategic voting. We use the model to explain voter behaviour at the most recent New Zealand general election.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective To provide 2-year clinical- and patient-oriented data with regard to mandibular overdenture assisted by 2 immediately loaded unsplinted implants. Material and methods In this pre-post design, Phase-I clinical trial, 18 edentate individuals (62.4 ± 7.7 years) received a new set of complete denture. Then, following standard procedures, 3 threaded implants (OsseoSpeed TX™, Dentsply Implants, Mölndal, Sweden) were placed in the mandible in each patient, and locator abutments (Zest Anchors LLC, Escondido, U.S.A.) were inserted on the right and left side implants. The midline implant served as a control for within-patient comparison. The immediate loading was conducted within 24 h of surgery. Data were collected at baseline (T0), 12 (T1) and 24 (T2) months after immediate loading. The clinical outcomes included implant survival rate, crestal bone level changes and implant stability. These criteria were assessed through clinical and radiographic examinations as well as resonance frequency analysis. Patient-centered outcomes included patient satisfaction and oral health-related quality of life measured using validated questionnaires. Brunner-Langer approach was used for statistical analysis. Results Implant survival rate for immediate loaded implants was 91.7% at 2-year follow-up. None of the unloaded implants failed. There was no statistically significant difference at baseline and follow-ups with regard to clinical outcomes between loaded and unloaded implants. Patient satisfaction and quality of life improved (p < 0.0001) from baseline to 2-year follow-up. Conclusion Immediate loading protocol did not negatively affect clinical outcomes, satisfaction and quality of life of patients wearing 2-unsplinted-implant mandibular overdenture for 2 years. This conclusion requires confirmation by randomized control trials. Clinical significance statement Mandibular overdenture assisted by two immediately-loaded unsplinted implants is successful treatment based on 2-year clinical and patient-based outcomes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mémoire numérisé par la Direction des bibliothèques de l'Université de Montréal.