13 resultados para gain measurement

em Université de Montréal, Canada


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The notion of diversity is an issue that is of relevance in several contexts. For example, the biodiversity of a given ecological environment and the diversity of the options available to a decision maker have attracted some attention in recent research. This paper provides an axiomatic approach to the measurement of diversity. We characterize two nested classes of ordinal measures of diversity and an important member of these classes. We prove that the latter special case is equivalent to a diversity ordering proposed by Weitzman.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper analyzes the measurement of the diversity of sets based on the dissimilarity of the objects contained in the set. We discuss axiomatic approaches to diversity measurement and examine the considerations underlying the application of specific measures. Our focus is on descriptive issues: rather than assuming a specific ethical position or restricting attention to properties that are appealing in specific applications, we address the foundations of the measurement issue as such in the context of diversity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Affiliation: Pierre Dagenais : Hôpital Maisonneuve-Rosemont, Faculté de médecine, Université de Montréal

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Les temps de réponse dans une tache de reconnaissance d’objets visuels diminuent de façon significative lorsque les cibles peuvent être distinguées à partir de deux attributs redondants. Le gain de redondance pour deux attributs est un résultat commun dans la littérature, mais un gain causé par trois attributs redondants n’a été observé que lorsque ces trois attributs venaient de trois modalités différentes (tactile, auditive et visuelle). La présente étude démontre que le gain de redondance pour trois attributs de la même modalité est effectivement possible. Elle inclut aussi une investigation plus détaillée des caractéristiques du gain de redondance. Celles-ci incluent, outre la diminution des temps de réponse, une diminution des temps de réponses minimaux particulièrement et une augmentation de la symétrie de la distribution des temps de réponse. Cette étude présente des indices que ni les modèles de course, ni les modèles de coactivation ne sont en mesure d’expliquer l’ensemble des caractéristiques du gain de redondance. Dans ce contexte, nous introduisons une nouvelle méthode pour évaluer le triple gain de redondance basée sur la performance des cibles doublement redondantes. Le modèle de cascade est présenté afin d’expliquer les résultats de cette étude. Ce modèle comporte plusieurs voies de traitement qui sont déclenchées par une cascade d’activations avant de satisfaire un seul critère de décision. Il offre une approche homogène aux recherches antérieures sur le gain de redondance. L’analyse des caractéristiques des distributions de temps de réponse, soit leur moyenne, leur symétrie, leur décalage ou leur étendue, est un outil essentiel pour cette étude. Il était important de trouver un test statistique capable de refléter les différences au niveau de toutes ces caractéristiques. Nous abordons la problématique d’analyser les temps de réponse sans perte d’information, ainsi que l’insuffisance des méthodes d’analyse communes dans ce contexte, comme grouper les temps de réponses de plusieurs participants (e. g. Vincentizing). Les tests de distributions, le plus connu étant le test de Kolmogorov- Smirnoff, constituent une meilleure alternative pour comparer des distributions, celles des temps de réponse en particulier. Un test encore inconnu en psychologie est introduit : le test d’Anderson-Darling à deux échantillons. Les deux tests sont comparés, et puis nous présentons des indices concluants démontrant la puissance du test d’Anderson-Darling : en comparant des distributions qui varient seulement au niveau de (1) leur décalage, (2) leur étendue, (3) leur symétrie, ou (4) leurs extrémités, nous pouvons affirmer que le test d’Anderson-Darling reconnait mieux les différences. De plus, le test d’Anderson-Darling a un taux d’erreur de type I qui correspond exactement à l’alpha tandis que le test de Kolmogorov-Smirnoff est trop conservateur. En conséquence, le test d’Anderson-Darling nécessite moins de données pour atteindre une puissance statistique suffisante.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectif principal: Il n’est pas démontré que les interventions visant à maîtriser voire modérer la médicamentation de patients atteints d’hypertension peuvent améliorer leur gestion de la maladie. Cette revue systématique propose d’évaluer les programmes de gestion contrôlée de la médicamentation pour l’hypertension, en s’appuyant sur la mesure de l’observance des traitements par les patients (CMGM). Design: Revue systématique. Sources de données: MEDLINE, EMBASE, CENTRAL, résumés de conférences internationales sur l’hypertension et bibliographies des articles pertinents. Méthodes: Des essais contrôlés randomisés (ECR) et des études observationnelles (EO) ont été évalués par 2 réviseurs indépendants. L’évaluation de la qualité (de ce matériel) a été réalisée avec l’aide de l’outil de Cochrane de mesure du risque de biais, et a été estimée selon une échelle à quatre niveaux de qualité Une synthèse narrative des données a été effectuée en raison de l'hétérogénéité importante des études. Résultats: 13 études (8 ECR, 5 EO) de 2150 patients hypertendus ont été prises en compte. Parmi elles, 5 études de CMGM avec l’utilisation de dispositifs électroniques comme seule intervention ont relevé une diminution de la tension artérielle (TA), qui pourrait cependant être expliquée par les biais de mesure. L’amélioration à court terme de la TA sous CMGM dans les interventions complexes a été révélée dans 4 études à qualité faible ou modérée. Dans 4 autres études sur les soins intégrés de qualité supérieure, il n'a pas été possible de distinguer l'impact de la composante CMGM, celle-ci pouvant être compromise par des traitements médicamenteux. L’ensemble des études semble par ailleurs montrer qu’un feed-back régulier au médecin traitant peut être un élément essentiel d’efficacité des traitements CMGM, et peut être facilement assuré par une infirmière ou un pharmacien, grâce à des outils de communication appropriés. Conclusions: Aucune preuve convaincante de l'efficacité des traitements CMGM comme technologie de la santé n’a été établie en raison de designs non-optimaux des études identifiées et des ualités méthodologiques insatisfaisantes de celles-ci. Les recherches futures devraient : suivre les normes de qualité approuvées et les recommandations cliniques actuelles pour le traitement de l'hypertension, inclure des groupes spécifiques de patients avec des problèmes d’attachement aux traitements, et considérer les résultats cliniques et économiques de l'organisation de soins ainsi que les observations rapportées par les patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Extensive social choice theory is used to study the problem of measuring group fitness in a two-level biological hierarchy. Both fixed and variable group size are considered. Axioms are identified that imply that the group measure satisfies a form of consequentialism in which group fitness only depends on the viabilities and fecundities of the individuals at the lower level in the hierarchy. This kind of consequentialism can take account of the group fitness advantages of germ-soma specialization, which is not possible with an alternative social choice framework proposed by Okasha, but which is an essential feature of the index of group fitness for a multicellular organism introduced by Michod, Viossat, Solari, Hurand, and Nedelcu to analyze the unicellular-multicellular evolutionary transition. The new framework is also used to analyze the fitness decoupling between levels that takes place during an evolutionary transition.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Le but de ce projet est d’étudier l’effet des défauts cristallins sur les propriétés optoélectroniques de photodétecteurs fabriqué à partir de « silicium noir », c’est-à-dire du silicium dopé et microstructuré par impulsions laser femtoseconde, ce qui lui donne une apparence noire mate caractéristique. Des échantillons de silicium noir ont été recuits puis implantés avec des ions ayant une énergie de 300 keV (Si+), 1500 keV (Si+) ou 2000 keV (H+). Trois fluences pour chaque énergie d’implantation ont été utilisées (1E11, 1E12, ou 1E13 ions/cm2) ce qui modifie le matériau en ajoutant des défauts cristallins à des profondeurs et concentrations variées. Neuf photodétecteurs ont été réalisés à partir de ces échantillons implantés, en plus d’un détecteur-contrôle (non-implanté). La courbe de courant-tension, la sensibilité spectrale et la réponse en fréquence ont été mesurées pour chaque détecteur afin de les comparer. Les détecteurs ont une relation de courant-tension presque ohmique, mais ceux implantés à plus haute fluence montrent une meilleure rectification. Les implantations ont eu pour effet, en général, d’augmenter la sensibilité des détecteurs. Par exemple, l’efficacité quantique externe passe de (0,069±0,001) % à 900 nm pour le détecteur-contrôle à (26,0±0,5) % pour le détecteur ayant reçu une fluence de 1E12 cm-2 d’ions de silicium de 1500 keV. Avec une tension appliquée de -0,50 V, la sensibilité est améliorée et certains détecteurs montrent un facteur de gain de photocourant supérieur à l’unité, ce qui implique un mécanisme de multiplication (avalanche ou photoconductivité). De même, la fréquence de coupure a été augmentée par l’implantation. Une technique purement optique a été mise à l’essai pour mesurer sans contacts la durée de vie effective des porteurs, dans le but d’observer une réduction de la durée de vie causée par les défauts. Utilisant le principe de la réflexion photo-induite résolue en fréquence, le montage n’a pas réuni toutes les conditions expérimentales nécessaires à la détection du signal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pre-publication drafts are reproduced with permission and copyright © 2013 of the Journal of Orthopaedic Trauma [Mutch J, Rouleau DM, Laflamme GY, Hagemeister N. Accurate Measurement of Greater Tuberosity Displacement without Computed Tomography: Validation of a method on Plain Radiography to guide Surgical Treatment. J Orthop Trauma. 2013 Nov 21: Epub ahead of print.] and copyright © 2014 of the British Editorial Society of Bone and Joint Surgery [Mutch JAJ, Laflamme GY, Hagemeister N, Cikes A, Rouleau DM. A new morphologic classification for greater tuberosity fractures of the proximal humerus: validation and clinical Implications. Bone Joint J 2014;96-B:In press.]

Relevância:

20.00% 20.00%

Publicador:

Resumo:

En opération depuis 2008, l’expérience ATLAS est la plus grande de toutes les expériences au LHC. Les détecteurs ATLAS- MPX (MPX) installés dans ATLAS sont basés sur le détecteur au silicium à pixels Medipix2 qui a été développé par la collaboration Medipix au CERN pour faire de l’imagerie en temps réel. Les détecteurs MPX peuvent être utilisés pour mesurer la luminosité. Ils ont été installés à seize différents endroits dans les zones expérimentale et technique d’ATLAS en 2008. Le réseau MPX a recueilli avec succès des données indépendamment de la chaîne d’enregistrement des données ATLAS de 2008 à 2013. Chaque détecteur MPX fournit des mesures de la luminosité intégrée du LHC. Ce mémoire décrit la méthode d’étalonnage de la luminosité absolue mesurée avec les détectors MPX et la performance des détecteurs MPX pour les données de luminosité en 2012. Une constante d’étalonnage de la luminosité a été déterminée. L’étalonnage est basé sur technique de van der Meer (vdM). Cette technique permet la mesure de la taille des deux faisceaux en recouvrement dans le plan vertical et horizontal au point d’interaction d’ATLAS (IP1). La détermination de la luminosité absolue nécessite la connaissance précise de l’intensité des faisceaux et du nombre de trains de particules. Les trois balayages d’étalonnage ont été analysés et les résultats obtenus par les détecteurs MPX ont été comparés aux autres détecteurs d’ATLAS dédiés spécifiquement à la mesure de la luminosité. La luminosité obtenue à partir des balayages vdM a été comparée à la luminosité des collisions proton- proton avant et après les balayages vdM. Le réseau des détecteurs MPX donne des informations fiables pour la détermination de la luminosité de l’expérience ATLAS sur un large intervalle (luminosité de 5 × 10^29 cm−2 s−1 jusqu’à 7 × 10^33 cm−2 s−1 .

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Full Text / Article complet

Relevância:

20.00% 20.00%

Publicador:

Resumo:

STUDY DESIGN: Concurrent validity between postural indices obtained from digital photographs (two-dimensional [2D]), surface topography imaging (three-dimensional [3D]), and radiographs. OBJECTIVE: To assess the validity of a quantitative clinical postural assessment tool of the trunk based on photographs (2D) as compared to a surface topography system (3D) as well as indices calculated from radiographs. SUMMARY OF BACKGROUND DATA: To monitor progression of scoliosis or change in posture over time in young persons with idiopathic scoliosis (IS), noninvasive and nonionizing methods are recommended. In a clinical setting, posture can be quite easily assessed by calculating key postural indices from photographs. METHODS: Quantitative postural indices of 70 subjects aged 10 to 20 years old with IS (Cobb angle, 15 degrees -60 degrees) were measured from photographs and from 3D trunk surface images taken in the standing position. Shoulder, scapula, trunk list, pelvis, scoliosis, and waist angles indices were calculated with specially designed software. Frontal and sagittal Cobb angles and trunk list were also calculated on radiographs. The Pearson correlation coefficients (r) was used to estimate concurrent validity of the 2D clinical postural tool of the trunk with indices extracted from the 3D system and with those obtained from radiographs. RESULTS: The correlation between 2D and 3D indices was good to excellent for shoulder, pelvis, trunk list, and thoracic scoliosis (0.81>r<0.97; P<0.01) but fair to moderate for thoracic kyphosis, lumbar lordosis, and thoracolumbar or lumbar scoliosis (0.30>r<0.56; P<0.05). The correlation between 2D and radiograph spinal indices was fair to good (-0.33 to -0.80 with Cobb angles and 0.76 for trunk list; P<0.05). CONCLUSION: This tool will facilitate clinical practice by monitoring trunk posture among persons with IS. Further, it may contribute to a reduction in the use of radiographs to monitor scoliosis progression.