6 resultados para Test (assessment)

em Université de Montréal, Canada


Relevância:

30.00% 30.00%

Publicador:

Resumo:

[Support Institutions:] Department of Administration of Health, University of Montreal, Canada Public Health School of Fudan University, Shanghai, China

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction : L’évaluation clinique du contrôle neuromusculaire des muscles du tronc est criante en réhabilitation et en entraînement. L’objectif principal de cette étude a été d’évaluer la reproductibilité intra et inter-évaluateur d’un test clinique le soulèvement actif de la jambe tendue (SAJT) chez une population active et saine. Méthode : Chaque sujet (18 joueurs de tennis) a été testé à deux reprises par 2 physiothérapeutes avec le SAJT. Résultats : La reproductibilité intra-évaluateur s’est avérée élevée à très élevée (ICC = 0.81 à 0.93) tandis la reproductibilité inter-évaluateur s’est avérée cliniquement non viable. Conclusion : À notre connaissance, le SAJT est le premier test clinique reproductible évaluant le contrôle neuromusculaire du tronc avec des compensations musculaires et cinétiques chez des sujets actifs et sains. Une formation plus importante des évaluateurs aurait certainement amélioré la reproductibilité inter-évaluateur.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

L'enseignement, l'apprentissage et l'évaluation du raisonnement clinique en sciences infirmières est un défi pour les éducateurs de cette profession et leurs étudiants. Depuis plusieurs décennies, les chercheurs et les éducateurs dans le domaine des sciences de la santé ont travaillé pour élaborer des instruments d'évaluation dans le but de pouvoir mesurer le raisonnement clinique (Charlin, Bordage & Van der Vleuten, 2003). Plusieurs études semblent appuyer le test de concordance de script (TCS) en termes de validité, fiabilité, faisabilité et applicabilité pour plusieurs disciplines et différents contextes (Carrière & al, 2009). Deschênes et ses collaborateurs (2006; Deschênes, Charlin, Gagnon & Goudreau, 2011) ont mis au point et validé un TCS spécifiquement pour le raisonnement clinique en sciences infirmières (RCI). Comme l'évaluation a un impact important sur les stratégies d'apprentissage des étudiants (Sibert et al, 2001; Durak, Caliskan & Bor, 2007), les outils d'évaluation valides et fiables qui permettraient l'identification des problèmes spécifiques dans le développement du raisonnement clinique en sciences infirmières seraient très utiles pour guider les décisions concernant l'éducation (Gierl, 2007). Nous avons donc mené une étude pour explorer le potentiel diagnostique des questions d'un TCS. La question de recherche est la suivante: «Dans quelle mesure chaque question d’un TCS visant à évaluer le RCI peut-elle être reliée à des catégories et des stratégies de pensée spécifiques?" Avec une sous-question: «Comment peut-on décrire le potentiel diagnostique d’un TCS pour évaluer le RCI?". Nous avons fait une deuxième analyse de contenu des données qui ont été obtenues dans une étude précédente dans laquelle cinq vignettes (15 questions) du TCS de Deschênes (2006) ont été utilisées. Les résultats ont montré les catégories et stratégies de pensées utilisées pour répondre à certaines questions du TCS selon les groupes de participants. Aussi, nos résultats ont permis de découvrir des disparités importantes entre les groupes, notamment que le RCI des expertes est si différent des étudiantes, qu’il ne peut servir de référence. Enfin, cette étude démontre que le TCS a un potentiel diagnostique niveau par niveau (1ère, 2e, 3e année et expertes) et non d’un niveau à un autre.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Triple quadrupole mass spectrometers coupled with high performance liquid chromatography are workhorses in quantitative bioanalyses. It provides substantial benefits including reproducibility, sensitivity and selectivity for trace analysis. Selected Reaction Monitoring allows targeted assay development but data sets generated contain very limited information. Data mining and analysis of non-targeted high-resolution mass spectrometry profiles of biological samples offer the opportunity to perform more exhaustive assessments, including quantitative and qualitative analysis. The objectives of this study was to test method precision and accuracy, statistically compare bupivacaine drug concentration in real study samples and verify if high resolution and accurate mass data collected in scan mode can actually permit retrospective data analysis, more specifically, extract metabolite related information. The precision and accuracy data presented using both instruments provided equivalent results. Overall, the accuracy was ranging from 106.2 to 113.2% and the precision observed was from 1.0 to 3.7%. Statistical comparisons using a linear regression between both methods reveal a coefficient of determination (R2) of 0.9996 and a slope of 1.02 demonstrating a very strong correlation between both methods. Individual sample comparison showed differences from -4.5% to 1.6% well within the accepted analytical error. Moreover, post acquisition extracted ion chromatograms at m/z 233.1648 ± 5 ppm (M-56) and m/z 305.2224 ± 5 ppm (M+16) revealed the presence of desbutyl-bupivacaine and three distinct hydroxylated bupivacaine metabolites. Post acquisition analysis allowed us to produce semiquantitative evaluations of the concentration-time profiles for bupicavaine metabolites.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective To determine overall, test–retest and inter-rater reliability of posture indices among persons with idiopathic scoliosis. Design A reliability study using two raters and two test sessions. Setting Tertiary care paediatric centre. Participants Seventy participants aged between 10 and 20 years with different types of idiopathic scoliosis (Cobb angle 15 to 60°) were recruited from the scoliosis clinic. Main outcome measures Based on the XY co-ordinates of natural reference points (e.g. eyes) as well as markers placed on several anatomical landmarks, 32 angular and linear posture indices taken from digital photographs in the standing position were calculated from a specially developed software program. Generalisability theory served to estimate the reliability and standard error of measurement (SEM) for the overall, test–retest and inter-rater designs. Bland and Altman's method was also used to document agreement between sessions and raters. Results In the random design, dependability coefficients demonstrated a moderate level of reliability for six posture indices (ϕ = 0.51 to 0.72) and a good level of reliability for 26 posture indices out of 32 (ϕ ≥ 0.79). Error attributable to marker placement was negligible for most indices. Limits of agreement and SEM values were larger for shoulder protraction, trunk list, Q angle, cervical lordosis and scoliosis angles. The most reproducible indices were waist angles and knee valgus and varus. Conclusions Posture can be assessed in a global fashion from photographs in persons with idiopathic scoliosis. Despite the good reliability of marker placement, other studies are needed to minimise measurement errors in order to provide a suitable tool for monitoring change in posture over time.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Study Design. Reliability study. Objectives. To assess between-acquisition reliability of new multilevel trunk cross sections measurements, in order to define what is a real change when comparing 2 trunk surface acquisitions of a same patient, before and after surgery or throughout the clinical monitoring. Summary of Background Data. Several cross-sectional surface measurements have been proposed in the literature for noninvasive assessment of trunk deformity in patients with adolescent idiopathic scoliosis (AIS). However, only the maximum values along the trunk are evaluated and used for monitoring progression and assessing treatment outcome. Methods. Back surface rotation (BSR), trunk rotation (TR), and coronal and sagittal trunk deviation are computed on 300 cross sections of the trunk. Each set of 300 measures is represented as a single functional data, using a set of basis functions. To evaluate between-acquisition variability at all trunk levels, a test-retest reliability study is conducted on 35 patients with AIS. A functional correlation analysis is also carried out to evaluate any redundancy between the measurements. Results. Each set of 300 measures was successfully described using only 10 basis functions. The test-retest reliability of the functional measurements is good to very good all over the trunk, except above the shoulders level. The typical errors of measurement are between 1.20° and 2.2° for the rotational measures and between 2 and 6 mm for deviation measures. There is a very strong correlation between BSR and TR all over the trunk, a moderate correlation between coronal trunk deviation and both BSR and TR, and no correlation between sagittal trunk deviation and any other measurement. Conclusion. This novel representation of trunk surface measurements allows for a global assessment of trunk surface deformity. Multilevel trunk measurements provide a broader perspective of the trunk deformity and allow a reliable multilevel monitoring during clinical follow-up of patients with AIS and a reliable assessment of the esthetic outcome after surgery.