13 resultados para Selective laser sintering
em Université de Montréal, Canada
Resumo:
It is not uncommon that a society facing a choice problem has also to choose the choice rule itself. In such situation voters’ preferences on alternatives induce preferences over the voting rules. Such a setting immediately gives rise to a natural question concerning consistency between these two levels of choice. If a choice rule employed to resolve the society’s original choice problem does not choose itself when it is also used in choosing the choice rule, then this phenomenon can be regarded as inconsistency of this choice rule as it rejects itself according to its own rationale. Koray (2000) proved that the only neutral, unanimous universally self-selective social choice functions are the dictatorial ones. Here we in troduce to our society a constitution, which rules out inefficient social choice rules. When inefficient social choice rules become unavailable for comparison, the property of self-selectivity becomes weaker and we show that some non-trivial self-selective social choice functions do exist. Under certain assumptions on the constitution we describe all of them.
Resumo:
BACKGROUND: HIV-1 Vpu targets newly synthesized CD4 receptor for rapid degradation by a process reminiscent of endoplasmic reticulum (ER)-associated protein degradation (ERAD). Vpu is thought to act as an adaptor protein, connecting CD4 to the ubiquitin (Ub)-proteasome degradative system through an interaction with beta-TrCP, a component of the SCFbeta-TrCP E3 Ub ligase complex. RESULTS: Here, we provide direct evidence indicating that Vpu promotes trans-ubiquitination of CD4 through recruitment of SCFbeta-TrCP in human cells. To examine whether Ub conjugation occurs on the cytosolic tail of CD4, we substituted all four Ub acceptor lysine residues for arginines. Replacement of cytosolic lysine residues reduced but did not prevent Vpu-mediated CD4 degradation and ubiquitination, suggesting that Vpu-mediated CD4 degradation is not entirely dependent on the ubiquitination of cytosolic lysines and as such might also involve ubiquitination of other sites. Cell fractionation studies revealed that Vpu enhanced the levels of ubiquitinated forms of CD4 detected in association with not only the ER membrane but also the cytosol. Interestingly, significant amounts of membrane-associated ubiquitinated CD4 appeared to be fully dislocated since they could be recovered following sodium carbonate salt treatment. Finally, expression of a transdominant negative mutant of the AAA ATPase Cdc48/p97 involved in the extraction of ERAD substrates from the ER membrane inhibited Vpu-mediated CD4 degradation. CONCLUSION: Taken together, these results are consistent with a model whereby HIV-1 Vpu targets CD4 for degradation by an ERAD-like process involving most likely poly-ubiquitination of the CD4 cytosolic tail by SCFbeta-TrCP prior to dislocation of receptor molecules across the ER membrane by a process that depends on the AAA ATPase Cdc48/p97.
Resumo:
La caractérisation de matériaux par spectroscopie optique d’émission d’un plasma induit par laser (LIPS) suscite un intérêt qui ne va que s’amplifiant, et dont les applications se multiplient. L’objectif de ce mémoire est de vérifier l’influence du choix des raies spectrales sur certaines mesures du plasma, soit la densité électronique et la température d’excitation des atomes neutres et ionisés une fois, ainsi que la température d’ionisation. Nos mesures sont intégrées spatialement et résolues temporellement, ce qui est typique des conditions opératoires du LIPS, et nous avons utilisé pour nos travaux des cibles binaires d’aluminium contenant des éléments à l’état de trace (Al-Fe et Al-Mg). Premièrement, nous avons mesuré la densité électronique à l’aide de l’élargissement Stark de raies de plusieurs espèces (Al II, Fe II, Mg II, Fe I, Mg I, Halpha). Nous avons observé que les densités absolues avaient un comportement temporel différent en fonction de l’espèce. Les raies ioniques donnent des densités électroniques systématiquement plus élevées (jusqu’à 50 % à 200 ns après l’allumage du plasma), et décroissent plus rapidement que les densités issues des raies neutres. Par ailleurs, les densités obtenues par les éléments traces Fe et Mg sont moindres que les densités obtenues par l’observation de la raie communément utilisée Al II à 281,618 nm. Nous avons parallèlement étudié la densité électronique déterminée à l’aide de la raie de l’hydrogène Halpha, et la densité électronique ainsi obtenue a un comportement temporel similaire à celle obtenue par la raie Al II à 281,618 nm. Les deux espèces partagent probablement la même distribution spatiale à l’intérieur du plasma. Finalement, nous avons mesuré la température d’excitation du fer (neutre et ionisé, à l’état de trace dans nos cibles), ainsi que la température d’ionisation, à l’aide de diagrammes de Boltzmann et de Saha-Boltzmann, respectivement. À l’instar de travaux antérieurs (Barthélémy et al., 2005), il nous est apparu que les différentes températures convergeaient vers une température unique (considérant nos incertitudes) après 2-3 microsecondes. Les différentes températures mesurées de 0 à 2 microsecondes ne se recoupent pas, ce qui pourrait s’expliquer soit par un écart à l’équilibre thermodynamique local, soit en considérant un plasma inhomogène où la distribution des éléments dans la plume n’est pas similaire d’un élément à l’autre, les espèces énergétiques se retrouvant au cœur du plasma, plus chaud, alors que les espèces de moindre énergie se retrouvant principalement en périphérie.
Investigation of femtosecond laser technology for the fabrication of drug nanocrystals in suspension
Resumo:
La technique du laser femtoseconde (fs) a été précédemment utilisée pour la production de nanoparticules d'or dans un environnement aqueux biologiquement compatible. Au cours de ce travail de maîtrise, cette méthode a été investiguée en vue d'une application pour la fabrication de nanocristaux de médicament en utilisant le paclitaxel comme modèle. Deux procédés distincts de cette technologie à savoir l'ablation et la fragmentation ont été étudiés. L'influence de la puissance du laser, de point de focalisation, et de la durée du traitement sur la distribution de taille des particules obtenues ainsi que leur intégrité chimique a été évaluée. Les paramètres ont ainsi été optimisés pour la fabrication des nanoparticules. L’évaluation morphologique et chimique a été réalisée par microscopie électronique et spectroscopie infrarouge respectivement. L'état cristallin des nanoparticules de paclitaxel a été caractérisé par calorimétrie differentielle et diffraction des rayons X. L'optimisation du procédé de production de nanoparticules par laser fs a permis d'obtenir des nanocristaux de taille moyenne (400 nm, polydispersité ≤ 0,3). Cependant une dégradation non négligeable a été observée. La cristallinité du médicament a été maintenue durant la procédure de réduction de taille, mais le paclitaxel anhydre a été transformé en une forme hydratée. Les résultats de cette étude suggèrent que le laser fs peut générer des nanocristaux de principe actif. Cependant cette technique peut se révéler problématique pour des médicaments sensibles à la dégradation. Grâce à sa facilité d'utilisation et la possibilité de travailler avec des quantités restreintes de produit, le laser fs pourrait représenter une alternative valable pour la production de nanoparticules de médicaments peu solubles lors des phases initiales de développement préclinique. Mots-clés: paclitaxel, nanocristaux, laser femtoseconde, ablation, fragmentation
Resumo:
La débitmétrie au laser à effet Doppler (LDF) constitue une méthode prometteuse et non-invasive pour l'étude du débit sanguin local dans l'œil. Cette technique est basée sur un changement de fréquence subi par la lumière lors du mouvement des globules rouges dans les vaisseaux. Une nouvelle sonde LDF a été testée pour sa sensibilité à évaluer la circulation rétinienne/choroïdienne sous des conditions hypercapniques et en présence de diverses substances vasoactives ou suivant la photocoagulation des artères rétiniennes chez le rat. Après dilatation pupillaire, la sonde LDF a été placée en contact avec la cornée de rats anesthésiés et parallèle à l'axe optique. L'hypercapnie a été provoquée par inhalation de CO2 (8% dans de l'air médical), alors que les agents pharmacologiques ont été injectés de façon intravitréenne. La contribution relative à la circulation choroïdienne a été évaluée à la suite de la photocoagulation des artères rétiniennes. Le débit sanguin s'est trouvé significativement augmenté à la suite de l'hypercanie (19%), de l'adénosine (14%) ou du nitroprusside de sodium (16%) comparativement au niveau de base, alors que l'endothéline-1 a provoqué une baisse du débit sanguin (11%). La photocoagulation des artères rétiniennes a significativement diminué le débit sanguin (33%). Des mesures en conditions pathologiques ont ensuite été obtenues après l'injection intravitréenne d'un agoniste sélectif du récepteur B1 (RB1). Ce récepteur des kinines est surexprimé dans la rétine des rats rendus diabétiques avec la streptozotocine (STZ) en réponse à l'hyperglycémie et au stress oxydatif. Les résultats ont montré que le RB1 est surexprimé dans la rétine chez les rats diabétiques-STZ à 4 jours et 6 semaines. À ces moments, le débit sanguin rétinien/choroïdien a été significativement augmenté (15 et 18 %) après l'injection de l'agoniste, suggérant un effet vasodilatateur des RB1 dans l'œil diabétique. Bien que la circulation choroïdienne contribue probablement au signal LDF, les résultats démontrent que le LDF représente une technique efficace et non-invasive pour l'étude de la microcirculation rétinienne in-vivo en continu. Cette méthode peut donc être utilisée pour évaluer de façon répétée les réponses du débit sanguin pendant des modifications métaboliques ou pharmacologiques dans des modèles animaux de maladies oculaires.
Resumo:
L’ablation de cibles d’Al nanocristallines (taille moyenne des cristallites d = 3,1 et 6,2 nm) par impulsions laser ultrabrèves (200 fs) a été étudiée par l’entremise de si- mulations combinant la dynamique moléculaire et le modèle à deux températures (two- temperature model, TTM) pour des fluences absorbées allant de 100 à 1300 J/m2. Nos simulations emploient un potentiel d’interaction de type EAM et les propriétés électro- niques des cibles en lien avec le TTM sont représentées par un modèle réaliste possédant une forme distincte dans le solide monocristallin, le solide nanocristallin et le liquide. Nous avons considéré l’effet de la taille moyenne des cristallites de même que celui de la porosité et nous avons procédé à une comparaison directe avec des cibles mono- cristallines. Nous avons pu montrer que le seuil d’ablation des métaux nanocristallins est significativement plus bas, se situant à 400 J/m2 plutôt qu’à 600 J/m2 dans le cas des cibles monocristallines, l’écart étant principalement dû à l’onde mécanique plus im- portante présente lors de l’ablation. Leur seuil de spallation de la face arrière est aussi significativement plus bas de par la résistance à la tension plus faible (5,40 GPa contre 7,24 GPa) des cibles nanocristallines. Il est aussi apparu que les contraintes résiduelles accompagnant généralement l’ablation laser sont absentes lors de l’ablation de cibles d’aluminium nanocristallines puisque la croissance cristalline leur permet d’abaisser leur volume spécifique. Nos résultats indiquent aussi que le seuil de fusion des cibles nano- cristallines est réduit de façon marquée dans ces cibles ce qui s’explique par la plus faible énergie de cohésion inhérente à ces matériaux. Nos simulations permettent de montrer que les propriétés structurelles et électroniques propres aux métaux nanocristallins ont toutes deux un impact important sur l’ablation.
Resumo:
The principal cause of mortality in patients with acute liver failure (ALF) is brain herniation resulting from intracranial hypertension caused by a progressive increase of brain water. In the present study, ex vivo high-resolution 1H-NMR spectroscopy was used to investigate the effects of ALF, with or without superimposed hypothermia, on brain organic osmolyte concentrations in relation to the severity of encephalopathy and brain edema in rats with ALF due to hepatic devascularization. In normothermic ALF rats, glutamine concentrations in frontal cortex increased more than fourfold at precoma stages, i.e. prior to the onset of severe encephalopathy, but showed no further increase at coma stages. In parallel with glutamine accumulation, the brain organic osmolytes myo-inositol and taurine were significantly decreased in frontal cortex to 63\% and 67\% of control values, respectively, at precoma stages (p<0.01), and to 58\% and 67\%, respectively, at coma stages of encephalopathy (p<0.01). Hypothermia, which prevented brain edema and encephalopathy in ALF rats, significantly attenuated the depletion of myo-inositol and taurine. Brain glutamine concentrations, on the other hand, did not respond to hypothermia. These findings demonstrate that experimental ALF results in selective changes in brain organic osmolytes as a function of the degree of encephalopathy which are associated with brain edema, and provides a further rationale for the continued use of hypothermia in the management of this condition.
Resumo:
Faculté de Pharmacie
Resumo:
INTRODUCTION: Emerging evidence indicates that nitric oxide (NO), which is increased in osteoarthritic (OA) cartilage, plays a role in 4-hydroxynonenal (HNE) generation through peroxynitrite formation. HNE is considered as the most reactive product of lipid peroxidation (LPO). We have previously reported that HNE levels in synovial fluids are more elevated in knees of OA patients compared to healthy individuals. We also demonstrated that HNE induces a panoply of inflammatory and catabolic mediators known for their implication in OA cartilage degradation. The aim of the present study was to investigate the ability of inducible NO synthase (iNOS) inhibitor, L-NIL (L-N6-(L-Iminoethyl)Lysine), to prevent HNE generation through NO inhibition in human OA chondrocytes. METHOD: Cells and cartilage explants were treated with or without either an NO generator (SIN or interleukin 1beta (IL-1β)) or HNE in absence or presence of L-NIL. Protein expression of both iNOS and free-radical-generating NOX subunit p47 (phox) were investigated by western blot. iNOS mRNA detection was measured by real-time RT-PCR. HNE production was analysed by ELISA, Western blot and immunohistochemistry. S-nitrosylated proteins were evaluated by Western Blot. Prostaglandin E2 (PGE2) and metalloproteinase 13 (MMP-13) levels as well as glutathione S-transferase (GST) activity were each assessed with commercial kits. NO release was determined using improved Griess method. Reactive oxygen species (ROS) generation was revealed using fluorescent microscopy with the use of commercial kits. RESULTS: L-NIL prevented IL-1β-induced NO release, iNOS expression at protein and mRNA levels, S-nitrosylated proteins and HNE in a dose dependent manner after 24h of incubation. Interestingly, we revealed that L-NIL abolished IL-1β-induced NOX component p47phox as well as ROS release. The HNE-induced PGE2 release and both cyclooxygenase-2 (COX-2) and MMP-13 expression were significantly reduced by L-NIL addition. Furthermore, L-NIL blocked the IL-1β induced inactivation of GST, an HNE-metabolizing enzyme. Also, L-NIL prevented HNE induced cell death at cytotoxic levels. CONCLUSION: Altogether, our findings support a beneficial effect of L-NIL in OA by preventing LPO process in NO-dependent and/or independent mechanisms.
Resumo:
Après des décennies de développement, l'ablation laser est devenue une technique importante pour un grand nombre d'applications telles que le dépôt de couches minces, la synthèse de nanoparticules, le micro-usinage, l’analyse chimique, etc. Des études expérimentales ainsi que théoriques ont été menées pour comprendre les mécanismes physiques fondamentaux mis en jeu pendant l'ablation et pour déterminer l’effet de la longueur d'onde, de la durée d'impulsion, de la nature de gaz ambiant et du matériau de la cible. La présente thèse décrit et examine l'importance relative des mécanismes physiques qui influencent les caractéristiques des plasmas d’aluminium induits par laser. Le cadre général de cette recherche forme une étude approfondie de l'interaction entre la dynamique de la plume-plasma et l’atmosphère gazeuse dans laquelle elle se développe. Ceci a été réalisé par imagerie résolue temporellement et spatialement de la plume du plasma en termes d'intensité spectrale, de densité électronique et de température d'excitation dans différentes atmosphères de gaz inertes tel que l’Ar et l’He et réactifs tel que le N2 et ce à des pressions s’étendant de 10‾7 Torr (vide) jusqu’à 760 Torr (pression atmosphérique). Nos résultats montrent que l'intensité d'émission de plasma dépend généralement de la nature de gaz et qu’elle est fortement affectée par sa pression. En outre, pour un délai temporel donné par rapport à l'impulsion laser, la densité électronique ainsi que la température augmentent avec la pression de gaz, ce qui peut être attribué au confinement inertiel du plasma. De plus, on observe que la densité électronique est maximale à proximité de la surface de la cible où le laser est focalisé et qu’elle diminue en s’éloignant (axialement et radialement) de cette position. Malgré la variation axiale importante de la température le long du plasma, on trouve que sa variation radiale est négligeable. La densité électronique et la température ont été trouvées maximales lorsque le gaz est de l’argon et minimales pour l’hélium, tandis que les valeurs sont intermédiaires dans le cas de l’azote. Ceci tient surtout aux propriétés physiques et chimiques du gaz telles que la masse des espèces, leur énergie d'excitation et d'ionisation, la conductivité thermique et la réactivité chimique. L'expansion de la plume du plasma a été étudiée par imagerie résolue spatio-temporellement. Les résultats montrent que la nature de gaz n’affecte pas la dynamique de la plume pour des pressions inférieures à 20 Torr et pour un délai temporel inférieur à 200 ns. Cependant, pour des pressions supérieures à 20 Torr, l'effet de la nature du gaz devient important et la plume la plus courte est obtenue lorsque la masse des espèces du gaz est élevée et lorsque sa conductivité thermique est relativement faible. Ces résultats sont confirmés par la mesure de temps de vol de l’ion Al+ émettant à 281,6 nm. D’autre part, on trouve que la vitesse de propagation des ions d’aluminium est bien définie juste après l’ablation et près de la surface de la cible. Toutefois, pour un délai temporel important, les ions, en traversant la plume, se thermalisent grâce aux collisions avec les espèces du plasma et du gaz.
Resumo:
L’ablation laser de verres métalliques de CuxZr1−x (x = 0.33, 0.50 et 0.67) et d’un alliage métallique cristallin de CuZr2 dans la structure C11b a été étudiée par dynamique moléculaire (DM) combinée à un modèle à deux températures (TTM). Le seuil d’ablation (Fth) a été déterminé pour chacun des 4 échantillons et s'est avéré plus bas pour les échantillons plus riches en Cu étant donné que la cohésion du Cu est plus faible que celle du Zr dans tous les échantillons. Pour x=0.33, Fth est plus bas pour le cristal que pour l’amorphe car le couplage électron-phonon est plus faible dans ce dernier, ce qui implique que l’énergie est transférée plus lentement du système électronique vers le système ionique pour le a-CuZr2 que le c-CuZr2. La vitesse de l’onde de pression créée par l’impact du laser croît avec la fluence dans l’échantillon cristallin, contrairement aux échantillons amorphes dans lesquels sa vitesse moyenne est relativement constante avec la fluence. Ceci est expliqué par le fait que le module de cisaillement croît avec la pression pour le cristal, ce qui n’est pas le cas pour les verres métalliques étudiés. Finalement, la zone affectée par la chaleur (HAZ) a été étudiée via la profondeur de fusion et les déformations plastiques. La plus faible température de fusion des échantillons amorphes implique que la profondeur de fusion est plus importante dans ceux-ci que dans l’échantillon cristallin. Dans les verres métalliques, les déformations plastiques ont été identifiées sous forme de zones de transformation par cisaillement (STZ) qui diffusent et fusionnent à plus haute fluence. Aucune déformation plastique importante n’a été identifiée dans le c-CuZr2 mis à part de légères déformations près du front de fusion causées par les contraintes résiduelles. Ce travail a ainsi permis d’améliorer notre compréhension de l’ablation laser sur les verres métalliques et de l’étendue des dommages qu’elle peut entraîner.
Resumo:
L’élevage des porcs représente une source importante de déversement d’antibiotiques dans l’environnement par l’intermédiaire de l’épandage du lisier qui contient une grande quantité de ces molécules sur les champs agricoles. Il a été prouvé que ces molécules biologiquement actives peuvent avoir un impact toxique sur l’écosystème. Par ailleurs, elles sont aussi suspectées d’engendrer des problèmes sanitaires et de contribuer à la résistance bactérienne pouvant mener à des infections difficilement traitables chez les humains. Le contrôle de ces substances dans l’environnement est donc nécessaire. De nombreuses méthodes analytiques sont proposées dans la littérature scientifique pour recenser ces composés dans plusieurs types de matrice. Cependant, peu de ces méthodes permettent l’analyse de ces contaminants dans des matrices issues de l’élevage agricole intensif. Par ailleurs, les méthodes analytiques disponibles sont souvent sujettes à des faux positifs compte tenu de la complexité des matrices étudiées et du matériel utilisé et ne prennent souvent pas en compte les métabolites et produits de dégradation. Enfin, les niveaux d’analyse atteints avec ces méthodes ne sont parfois plus à jour étant donné l’évolution de la chimie analytique et de la spectrométrie de masse. Dans cette optique, de nouvelles méthodes d’analyses ont été développées pour rechercher et quantifier les antibiotiques dans des matrices dérivées de l’élevage intensif des porcs en essayant de proposer des approches alternatives sensibles, sélectives et robustes pour quantifier ces molécules. Une première méthode d’analyse basée sur une technique d’introduction d’échantillon alternative à l’aide d’une interface fonctionnant à l’aide d’une désorption thermique par diode laser munie d’une source à ionisation à pression atmosphérique, couplée à la spectrométrie de masse en tandem a été développée. L’objectif est de proposer une analyse plus rapide tout en atteignant des niveaux de concentration adaptés à la matrice étudiée. Cette technique d’analyse couplée à un traitement d’échantillon efficace a permis l’analyse de plusieurs antibiotiques vétérinaires de différentes classes dans des échantillons de lisier avec des temps d’analyse courts. Les limites de détection atteintes sont comprises entre 2,5 et 8,3 µg kg-1 et sont comparables avec celles pouvant être obtenues avec la chromatographie liquide dans une matrice similaire. En vue d’analyser simultanément une série de tétracyclines, une deuxième méthode d’analyse utilisant la chromatographie liquide couplée à la spectrométrie de masse à haute résolution (HRMS) a été proposée. L’utilisation de la HRMS a été motivée par le fait que cette technique d’analyse est moins sensible aux faux positifs que le triple quadripôle traditionnel. Des limites de détection comprises entre 1,5 et 3,6 µg kg-1 ont été atteintes dans des échantillons de lisier en utilisant un mode d’analyse par fragmentation. L’utilisation de méthodes de quantifications ciblées est une démarche intéressante lorsque la présence de contaminants est suspectée dans un échantillon. Toutefois, les contaminants non intégrés à cette méthode d’analyse ciblée ne peuvent être détectés même à de fortes concentrations. Dans ce contexte, une méthode d’analyse non ciblée a été développée pour la recherche de pharmaceutiques vétérinaires dans des effluents agricoles en utilisant la spectrométrie de masse à haute résolution et une cartouche SPE polymérique polyvalente. Cette méthode a permis l’identification d’antibiotiques et de pharmaceutiques couramment utilisés dans l’élevage porcin. La plupart des méthodes d’analyse disponibles dans la littérature se concentrent sur l’analyse des composés parents, mais pas sur les sous-produits de dégradation. L’approche utilisée dans la deuxième méthode d’analyse a donc été étendue et appliquée à d’autres classes d’antibiotiques pour mesurer les concentrations de plusieurs résidus d’antibiotiques dans les sols et les eaux de drainage d’un champ agricole expérimental. Les sols du champ renfermaient un mélange d’antibiotiques ainsi que leurs produits de dégradation relatifs à des concentrations mesurées jusqu’à 1020 µg kg-1. Une partie de ces composés ont voyagé par l’intermédiaire des eaux de drainage du champ ou des concentrations pouvant atteindre 3200 ng L-1 ont pu être relevées.