11 resultados para Peri-implant soft tissue

em Université de Montréal, Canada


Relevância:

100.00% 100.00%

Publicador:

Resumo:

One of the major concerns of scoliotic patients undergoing spinal correction surgery is the trunk's external appearance after the surgery. This paper presents a novel incremental approach for simulating postoperative trunk shape in scoliosis surgery. Preoperative and postoperative trunk shapes data were obtained using three-dimensional medical imaging techniques for seven patients with adolescent idiopathic scoliosis. Results of qualitative and quantitative evaluations, based on the comparison of the simulated and actual postoperative trunk surfaces, showed an adequate accuracy of the method. Our approach provides a candidate simulation tool to be used in a clinical environment for the surgery planning process.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Les patients atteints de mono-traumatisme à un membre doivent consulter un médecin de première ligne qui assurera la prise en charge initiale et référera au besoin le patient vers un orthopédiste. L‟objectif principal de cette étude est de décrire ce mécanisme de référence envers un Service d‟orthopédie affilié à un Centre de traumatologie Niveau 1. La collecte de données concernant l‟accès aux soins spécialisés et la qualité des soins primaires a été faite lors de la visite en orthopédie. Nous avons étudié 166 patients consécutifs référés en orthopédie sur une période de 4 mois. Avant leur référence en orthopédie, 23 % des patients ont dû consulter 2 médecins de première ligne ou plus pour leur blessure. Le temps entre la consultation en première ligne et la visite en orthopédie (68 heures) dépasse le temps compris entre le traumatisme et l‟accès au généraliste (21 heures). Parmi les cas jugés urgents, 36 % n‟ont pas été vus dans les temps recommandés. La qualité des soins de première ligne fut sous-optimale chez 49 % des patients concernant l‟analgésie, l‟immobilisation et/ou l‟aide à la marche. Les facteurs associés à une diminution d‟accès en orthopédie et/ou une qualité de soins inférieure sont : tabagisme, jeune âge, habiter loin de l‟hôpital, consulter initialement une clinique privée, avoir une blessure au membre inférieur ou des tissus mous et une faible sévérité de la blessure selon le patient. Ces résultats démontrent qu‟il faut mieux cibler l‟enseignement relié aux mono-traumatismes envers les médecins de première ligne afin d‟améliorer le système de référence.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Le desserrage des tiges est une complication fréquente des plâtres avec tiges transcorticales (TP) chez les grands animaux, nécessitant souvent leur retrait prématuré avant la guérison des fractures. Les charges excessives centrées sur le cortex à l’interface os-tige proximo-externe et disto-interne causent de l'ostéolyse. En utilisant un modèle de veau nouveau-né, ce projet a évalué un nouveau système de tige-manchon et anneau integré dans un plâtre (PS) optimisé pour réduire la contrainte péri-implant et le stress à l'interface os-implant. On a émis l'hypothèse que les PS se traduiraient par une ostéolyse péri-implant moindre par rapport aux TP. Dix veaux en bonne santé, de 3 semaines d'âge, ont été implantés avec les TP ou PS dans le métacarpe droit, à raison de 2 implants par veau. Les veaux ont été observés quotidiennement pour le confort et la boiterie et ont été euthanasiés à 28 jours. Les données recueillies comprenaient les radiographies à la chirurgie et à l'euthanasie et les mesures histomorphométriques de contact os-implant sur des échantillons non-décalcifiés avec les implants in situ. Les données ont été analysées en utilisant le test de Cochran-Mantel-Haenszel, une valeur de P <0,05 a été considérée comme significative. L'épaisseur corticale était plus importante pour les implants distaux que proximaux pour les deux groupes lors de la chirurgie (P = 0,03), mais était similaire entre les groupes (P > 0,3). Les veaux avec TP ont développé une boiterie plus tôt (au jour 21) que les veaux avec PS (P = 0,04). Histologiquement, il y avait plus de contact direct os-implant cortical pour les implants PS distaux que les implants TP (P = 0,04). La jonction métaphyso-diaphysaire osseuse où les implants proximaux étaient situés est impropre aux deux systèmes; chacun a un minimum de contact os-implant et de l'ostéolyse extensive. Le système PS n'ayant pas causé une ostéolyse importante lorsque implantés dans l'os diaphysaire et peut-être une alternative convenable aux TP pour des fractures comminutives des membres distaux.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

L’analyse biomécanique du mouvement humain en utilisant des systèmes optoélectroniques et des marqueurs cutanés considère les segments du corps comme des corps rigides. Cependant, le mouvement des tissus mous par rapport à l'os, c’est à dire les muscles et le tissu adipeux, provoque le déplacement des marqueurs. Ce déplacement est le fait de deux composantes, une composante propre correspondant au mouvement aléatoire de chaque marqueur et une composante à l’unisson provoquant le déplacement commun des marqueurs cutanés lié au mouvement des masses sous-jacentes. Si nombre d’études visent à minimiser ces déplacements, des simulations ont montré que le mouvement des masses molles réduit la dynamique articulaire. Cette observation est faite uniquement par la simulation, car il n'existe pas de méthodes capables de dissocier la cinématique des masses molles de celle de l’os. L’objectif principal de cette thèse consiste à développer une méthode numérique capable de distinguer ces deux cinématiques. Le premier objectif était d'évaluer une méthode d'optimisation locale pour estimer le mouvement des masses molles par rapport à l’humérus obtenu avec une tige intra-corticale vissée chez trois sujets. Les résultats montrent que l'optimisation locale sous-estime de 50% le déplacement des marqueurs et qu’elle conduit à un classement de marqueurs différents en fonction de leur déplacement. La limite de cette méthode vient du fait qu'elle ne tient pas compte de l’ensemble des composantes du mouvement des tissus mous, notamment la composante en unisson. Le second objectif était de développer une méthode numérique qui considère toutes les composantes du mouvement des tissus mous. Plus précisément, cette méthode devait fournir une cinématique similaire et une plus grande estimation du déplacement des marqueurs par rapport aux méthodes classiques et dissocier ces composantes. Le membre inférieur est modélisé avec une chaine cinématique de 10 degrés de liberté reconstruite par optimisation globale en utilisant seulement les marqueurs placés sur le pelvis et la face médiale du tibia. L’estimation de la cinématique sans considérer les marqueurs placés sur la cuisse et le mollet permet d'éviter l’influence de leur déplacement sur la reconstruction du modèle cinématique. Cette méthode testée sur 13 sujets lors de sauts a obtenu jusqu’à 2,1 fois plus de déplacement des marqueurs en fonction de la méthode considérée en assurant des cinématiques similaires. Une approche vectorielle a montré que le déplacement des marqueurs est surtout dû à la composante à l’unisson. Une approche matricielle associant l’optimisation locale à la chaine cinématique a montré que les masses molles se déplacent principalement autour de l'axe longitudinal et le long de l'axe antéro-postérieur de l'os. L'originalité de cette thèse est de dissocier numériquement la cinématique os de celle des masses molles et les composantes de ce mouvement. Les méthodes développées dans cette thèse augmentent les connaissances sur le mouvement des masses molles et permettent d’envisager l’étude de leur effet sur la dynamique articulaire.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: Il est important de minimiser le gaspillage et les risques associés aux soins sans valeur. La gestion de l’utilisation des antimicrobiens vise à optimiser leur emploi et doit être adaptée au milieu et à sa population. Objectifs: Évaluer les profiles d’utilisation actuels des antimicrobiens et fixer des objectifs pour les interventions en matière de gestion des antimicrobiens. Méthode: Vingt-et-un hôpitaux du Nouveau-Brunswick offrant des soins de courte durée en médecine générale, en chirurgie et en pédiatrie ont pris part à une enquête sur la prévalence ponctuelle. Tous les patients admis aux hôpitaux participants et ayant reçu au moins un antimicrobien systémique ont été inscrits à l’étude. Les principaux critères d’évaluation étaient le profil d’utilisation, selon l’indication et l’antimicrobien prescrit, le bienfondé de l’utilisation et la durée de la prophylaxie chirurgicale. Des statistiques descriptives et un test d’indépendance 2 furent utilisés pour l’analyse de données. Résultats: L’enquête a été menée de juin à août 2012. Un total de 2244 patients ont été admis pendant la durée de l’étude et 529 (23,6%) ont reçu un antimicrobien. Au total, 691 antimicrobiens ont été prescrits, soit 587 (85%) pour le traitement et 104 (15%) pour la prophylaxie. Les antimicrobiens les plus souvent prescrits pour le traitement (n=587) étaient des classes suivantes : quinolones (25,6%), pénicillines à spectre étendu (10,2%) et métronidazole (8,5%). Les indications les plus courantes du traitement étaient la pneumonie (30%), les infections gastro-intestinales (16%) et les infections de la peau et des tissus mous (14%). Selon des critères définis au préalable, 23% (n=134) des ordonnances pour le traitement étaient inappropriées et 20% (n=120) n’avaient aucune indication de documentée. Les domaines où les ordonnances étaient inappropriées étaient les suivants : défaut de passage de la voie intraveineuse à la voie orale (n=34, 6%), mauvaise dose (n=30, 5%), traitement d’une bactériurie asymptomatique (n=24, 4%) et doublement inutile (n=22, 4%). Dans 33% (n=27) des cas, les ordonnances pour la prophylaxie chirurgicale étaient pour une période de plus de 24 heures. Conclusions: Les résultats démontrent que les efforts de gestion des antimicrobiens doivent se concentrer sur les interventions conventionnelles de gestion de l’utilisation des antimicrobiens, l’amélioration de la documentation, l’optimisation de l’utilisation des quinolones et la réduction au minimum de la durée de la prophylaxie chirurgicale.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Problématique : L’édentement et les troubles du sommeil sont des affections chroniques fréquentes chez les personnes âgées et qui peuvent avoir des conséquences défavorables sur le bien-être de ces personnes, ainsi que sur leur qualité de vie. L’édentement pourrait perturber le sommeil par la modification de la structure crânio-faciale et des tissus mous environnants. Cependant, cette relation n'est pas suffisamment documenté. Objectifs : Le but de cette étude pilote était de préparer la mise en œuvre d’une étude clinique randomisée contrôlée concernant l’effet du port nocturne des prothèses complètes sur la qualité du sommeil. Méthodologie : Treize aînés édentés ont participé à cette étude clinique randomisée contrôlée de type croisé. L’intervention consistait à dormir avec ou sans les prothèses durant la nuit. Les participants à l'étude ont été assignés à porter et ne pas porter leurs prothèses dans des ordres alternatifs pour des périodes de 30 jours. La qualité du sommeil a été évaluée par la polysomnographie portable et le questionnaire Pittburgh Sleep Quality Index (PSQI). Les données supplémentaires incluent la somnolence diurne, évaluée par le questionnaire Epworth Sleepiness Scale (ESS), et la qualité de vie liée à la santé buccodentaire, évaluée par le questionnaire Oral Health Impact Profile 20 (OHIP-20). De plus, à travers les examens cliniques et radiologiques, les données des caractéristiques sociodémographiques, de la morphologie oropharyngée, des caractéristiques buccodentaires et des prothèses ont été recueillies. Les modèles de régression linéaire pour les mesures répétées ont été utilisés pour analyser les résultats. Résultats : L’étude de faisabilité a atteint un taux de recrutement à l’étude de 59,1% et un taux de suivi de 100%. Le port nocturne des prothèses dentaires augmentait l’index d'apnée-hypopnée (IAH) et le score PSQI par rapport au non port nocturne des prothèses : (IAH : Médiane = 20,9 (1,3 - 84,7) versus 11,2 (1,9 - 69,6), p = 0,237; le score PSQI : Médiane = 6,0 (3,0 - 11,0) versus 5,0 (1,0 - 11,0), p = 0,248). Cependant, ces différences n'étaient pas statistiquement significatives, sauf que pour le temps moyen d’apnée (plus long avec des prothèses) (p < 0,005) et le temps de ronflement relatif (moins élevé avec des prothèses) (p < 0,05). La somnolence diurne excessive et la qualité de vie liée à la santé buccodentaire étaient semblables pour les deux interventions (le score ESS : Médiane = 4,0 (3,0-10,0) versus 5,0 (2,0-10,0), p = 0,746; le score OHIP-20: Médiane = 31,0 (20,0-64,0) versus 27,0 (20,0-49,0), p = 0,670). L’impact néfaste du port nocturne des prothèses complètes sur le sommeil a été statistiquement significatif chez les personnes souffrant de l’apnée-hypopnée moyenne à sévère (p < 0,005). Conclusion : L’essai clinique pilote a montré que le port nocturne des prothèses complètes a un impact négatif sur la qualité du sommeil des gens âgés édentés, surtout chez les personnes avec l’apnée obstructive du sommeil modérée à sévère. Les résultats doivent être confirmés par l’étude clinique randomisée contrôlée de phase II.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A method for the construction of a patient-specific model of a scoliotic torso for surgical planning via inter- patient registration is presented. Magnetic Resonance Images (MRI) of a generic model are registered to surface topography (TP) and X-ray data of a test patient. A partial model is first obtained via thin-plate spline registration between TP and X-ray data of the test patient. The MRIs from the generic model are then fit into the test patient using articulated model registration between the vertebrae of the generic model’s MRIs in prone position and the test patient’s X-rays in standing position. A non-rigid deformation of the soft tissues is performed using a modified thin-plate spline constrained to maintain bone rigidity and to fit in the space between the vertebrae and the surface of the torso. Results show average Dice values of 0.975 ± 0.012 between the MRIs following inter-patient registration and the surface topography of the test patient, which is comparable to the average value of 0.976 ± 0.009 previously obtained following intra-patient registration. The results also show a significant improvement compared to rigid inter-patient registration. Future work includes validating the method on a larger cohort of patients and incorporating soft tissue stiffness constraints. The method developed can be used to obtain a geometric model of a patient including bone structures, soft tissues and the surface of the torso which can be incorporated in a surgical simulator in order to better predict the outcome of scoliosis surgery, even if MRI data cannot be acquired for the patient.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background This paper presents a method that registers MRIs acquired in prone position, with surface topography (TP) and X-ray reconstructions acquired in standing position, in order to obtain a 3D representation of a human torso incorporating the external surface, bone structures, and soft tissues. Methods TP and X-ray data are registered using landmarks. Bone structures are used to register each MRI slice using an articulated model, and the soft tissue is confined to the volume delimited by the trunk and bone surfaces using a constrained thin-plate spline. Results The method is tested on 3 pre-surgical patients with scoliosis and shows a significant improvement, qualitatively and using the Dice similarity coefficient, in fitting the MRI into the standing patient model when compared to rigid and articulated model registration. The determinant of the Jacobian of the registration deformation shows higher variations in the deformation in areas closer to the surface of the torso. Conclusions The novel, resulting 3D full torso model can provide a more complete representation of patient geometry to be incorporated in surgical simulators under development that aim at predicting the effect of scoliosis surgery on the external appearance of the patient’s torso.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper provides an overview of work done in recent years by our research group to fuse multimodal images of the trunk of patients with Adolescent Idiopathic Scoliosis (AIS) treated at Sainte-Justine University Hospital Center (CHU). We first describe our surface acquisition system and introduce a set of clinical measurements (indices) based on the trunk's external shape, to quantify its degree of asymmetry. We then describe our 3D reconstruction system of the spine and rib cage from biplanar radiographs and present our methodology for multimodal fusion of MRI, X-ray and external surface images of the trunk We finally present a physical model of the human trunk including bone and soft tissue for the simulation of the surgical outcome on the external trunk shape in AIS.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

L’épaule est l’articulation la plus mobile et la plus instable du corps humain dû à la faible quantité de contraintes osseuses et au rôle des tissus mous qui lui confèrent au moins une dizaine de degrés de liberté. La mobilité de l’épaule est un facteur de performance dans plusieurs sports. Mais son instabilité engendre des troubles musculo-squelettiques, dont les déchirures de la coiffe des rotateurs sont fréquentes et les plus handicapantes. L’évaluation de l’amplitude articulaire est un indice commun de la fonction de l’épaule, toutefois elle est souvent limitée à quelques mesures planaires pour lesquelles les degrés de liberté varient indépendamment les uns des autres. Ces valeurs utilisées dans les modèles de simulation musculo-squelettiques peuvent amener à des solutions non physiologiques. L’objectif de cette thèse était de développer des outils pour la caractérisation de la mobilité articulaire tri-dimensionnelle de l’épaule, en passant par i) fournir une méthode et son approche expérimentale pour évaluer l’amplitude articulaire tridimensionnelle de l’épaule incluant des interactions entre les degrés de liberté ; ii) proposer une représentation permettant d’interpréter les données tri-dimensionnelles obtenues; iii) présenter des amplitudes articulaires normalisées, iv) implémenter une amplitude articulaire tridimensionnelle au sein d’un modèle de simulation numérique afin de générer des mouvements sportifs optimaux plus réalistes; v) prédire des amplitudes articulaires sécuritaires et vi) des exercices de rééducation sécuritaires pour des patients ayant subi une réparation de la coiffe des rotateurs. i) Seize sujets ont été réalisé séries de mouvements d’amplitudes maximales actifs avec des combinaisons entre les différents degrés de liberté de l’épaule. Un système d’analyse du mouvement couplé à un modèle cinématique du membre supérieur a été utilisé pour estimer les cinématiques articulaires tridimensionnelles. ii) L’ensemble des orientations définies par une séquence de trois angles a été inclus dans un polyèdre non convexe représentant l’espace de mobilité articulaire prenant en compte les interactions entre les degrés de liberté. La combinaison des séries d’élévation et de rotation est recommandée pour évaluer l’amplitude articulaire complète de l’épaule. iii) Un espace de mobilité normalisé a également été défini en englobant les positions atteintes par au moins 50% des sujets et de volume moyen. iv) Cet espace moyen, définissant la mobilité physiologiques, a été utilisé au sein d’un modèle de simulation cinématique utilisé pour optimiser la technique d’un élément acrobatique de lâcher de barres réalisée par des gymnastes. Avec l’utilisation régulière de limites articulaires planaires pour contraindre la mobilité de l’épaule, seulement 17% des solutions optimales sont physiologiques. En plus, d’assurer le réalisme des solutions, notre contrainte articulaire tridimensionnelle n’a pas affecté le coût de calculs de l’optimisation. v) et vi) Les seize participants ont également réalisé des séries d’amplitudes articulaires passives et des exercices de rééducation passifs. La contrainte dans l’ensemble des muscles de la coiffe des rotateurs au cours de ces mouvements a été estimée à l’aide d’un modèle musculo-squelettique reproduisant différents types et tailles de déchirures. Des seuils de contrainte sécuritaires ont été utilisés pour distinguer les amplitudes de mouvements risquées ou non pour l’intégrité de la réparation chirurgicale. Une taille de déchirure plus grande ainsi que les déchirures affectant plusieurs muscles ont contribué à réduire l’espace de mobilité articulaire sécuritaire. Principalement les élévations gléno-humérales inférieures à 38° et supérieures à 65°, ou réalisées avec le bras maintenu en rotation interne engendrent des contraintes excessives pour la plupart des types et des tailles de blessure lors de mouvements d’abduction, de scaption ou de flexion. Cette thèse a développé une représentation innovante de la mobilité de l’épaule, qui tient compte des interactions entre les degrés de liberté. Grâce à cette représentation, l’évaluation clinique pourra être plus exhaustive et donc élargir les possibilités de diagnostiquer les troubles de l’épaule. La simulation de mouvement peut maintenant être plus réaliste. Finalement, nous avons montré l’importance de personnaliser la rééducation des patients en termes d’amplitude articulaire, puisque des exercices passifs de rééducation précoces peuvent contribuer à une re-déchirure à cause d’une contrainte trop importante qu’ils imposent aux tendons.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Le byssus est un amas de fibres que les moules produisent afin de s’ancrer aux surfaces immergées sous l’eau. Ces fibres sont pourvues de propriétés mécaniques impressionnantes combinant rigidité, élasticité et ténacité élevées. De plus, elles possèdent un comportement d’auto-guérison de leurs propriétés mécaniques en fonction du temps lorsque la contrainte initialement appliquée est retirée. Les propriétés mécaniques de ces fibres sont le résultat de l’agencement hiérarchique de protéines de type copolymère blocs riches en collagène et de la présence de métaux formant des liens sacrificiels réversibles avec certains acides aminés comme les DOPA et les histidines. Bien que cette fibre soit très intéressante pour la production de matériaux grâce à son contenu élevé en collagène potentiellement biocompatible, cette ressource naturelle est traitée comme un déchet par les mytiliculteurs. L’objectif de cette thèse était de valoriser cette fibre en extrayant les protéines pour générer une nouvelle classe de matériaux biomimétiques. Un hydrolysat de protéines de byssus (BPH) riche en acides aminés chargés, i.e. ~30 % mol, et permettant de former des films a pu être généré. Lorsque solubilisé à pH 10.5, le BPH forme un hydrogel contenant des structures en triple hélice de collagène et des feuillets β anti-parallèles intra- et inter-moléculaires. Suite à l’évaporation de l’eau, le film de BPH résultant est insoluble en milieu aqueux à cause des structures secondaires très stables agissant comme points de réticulation effectifs. Les propriétés mécaniques des films de BPH sont modulables en fonction du pH. Au point isoélectrique (pI = 4.5), les interactions électrostatiques entre les charges opposées agissent comme points de réticulation et augmentent la rigidité des films et leur contrainte à la rupture sans affecter la déformation à la rupture. À pH plus élevé ou plus bas que le pI, les performances mécaniques des films sont plus faibles à cause de la répulsion entre les groupements fonctionnels de même charge qui interagissent plutôt avec les molécules d’eau et causent le gonflement de la matrice protéique des films. Le BPH contenant un nombre élevé d’acides aminés chargés et réactifs, nous avons pu réticuler les films de manière covalente à l’aide d’EDC ou de glutaraldéhyde. Les propriétés mécaniques des films sont modulables en fonction de la concentration d’EDC utilisée lors de la réticulation ou en employant du glutaraldéhyde comme agent réticulant. Les films sont à la fois plus rigides et plus forts avec un degré de réticulation élevé, mais perdent leur extensibilité à mesure que les segments libres de s’étirer lors d’une traction deviennent entravés par les points de réticulation. La réticulation augmente également la résistance à la dégradation enzymatique par la collagénase, les films les plus fortement réticulés lui étant pratiquement insensibles. La spectroscopie infrarouge montre enfin que la réticulation entraîne une transition de feuillets β anti-parallèles inter-moléculaires vers des structures de type hélices de collagène/PPII hydratées. Des liens sacrificiels ont été formés dans les films de BPH par traitement au pI et/ou avec différents métaux, i.e. Na+, Ca2+, Fe3+, afin de moduler les propriétés mécaniques statiques et d’évaluer le rôle de ces traitements sur le comportement d’auto-guérison lors de tests mécaniques cycliques avec différents temps de repos. Plus la valence des ions métalliques ajoutés augmente, plus les propriétés mécaniques statiques affichent un module, une contrainte à la rupture et une ténacité élevés sans toutefois affecter la déformation à la rupture, confirmant la formation de liens sacrificiels. Les tests mécaniques cycliques montrent que les traitements au pI ou avec Ca2+ créent des liens sacrificiels ioniques réversibles qui mènent à un processus d’auto-guérison des performances mécaniques dépendant du pH. L’ajout de Fe3+ à différentes concentrations module les performances mécaniques sur un plus large intervalle et la nature plus covalente de son interaction avec les acides aminés permet d’atteindre des valeurs nettement plus élevées que les autres traitements étudiés. Le Fe3+ permet aussi la formation de liens sacrificiels réversibles menant à l’auto-guérison des propriétés mécaniques. Les spectroscopies Raman et infrarouge confirment que le fer crée des liaisons avec plusieurs acides aminés, dont les histidines et les DOPA. Les résultats dans leur ensemble démontrent que les films de BPH sont des hydrogels biomimétiques du byssus qui peuvent être traités ou réticulés de différentes façons afin de moduler leurs performances mécaniques. Ils pourraient ainsi servir de matrices pour des applications potentielles dans le domaine pharmaceutique ou en ingénierie tissulaire.