21 resultados para Objective function values
em Université de Montréal, Canada
Resumo:
The attached file is created with Scientific Workplace Latex
Resumo:
We investigate the conditions under which an inequality averse and additively separable welfarist constitution maker would always choose to set up a progressive equalization payments scheme in a federation with local public goods. A progressive equalization payments scheme is defined as a list of per capita net (possibly negative) subsidies - one such net subsidy for every jurisdiction - that are decreasing with respect to jurisdictions per capita wealth. We examine these questions in a setting in which the case for progressivity is a priori the strongest, namely, all citizens have the same utility function for the private and the public goods, inhabitants of a given jurisdiction are all identical, and they are not able to move across jurisdictions. We show that the constitution maker favors a progressive equalization payments scheme for all distributions of wealth and all population sizes if and only if its objective function is additively separable between each jurisdiction’s per capita wealth and number of inhabitants. When interpreted as a mean of order r social welfare function, this condition is shown to be equivalent to additive separability of the individual’s indirect utility function with respect to wealth and the price of the public good. Some implications of this restriction to the case where the individual’s direct utility function is additively separable are also derived.
Resumo:
La traduction automatique statistique est un domaine très en demande et où les machines sont encore loin de produire des résultats de qualité humaine. La principale méthode utilisée est une traduction linéaire segment par segment d'une phrase, ce qui empêche de changer des parties de la phrase déjà traduites. La recherche pour ce mémoire se base sur l'approche utilisée dans Langlais, Patry et Gotti 2007, qui tente de corriger une traduction complétée en modifiant des segments suivant une fonction à optimiser. Dans un premier temps, l'exploration de nouveaux traits comme un modèle de langue inverse et un modèle de collocation amène une nouvelle dimension à la fonction à optimiser. Dans un second temps, l'utilisation de différentes métaheuristiques, comme les algorithmes gloutons et gloutons randomisés permet l'exploration plus en profondeur de l'espace de recherche et permet une plus grande amélioration de la fonction objectif.
Development of new scenario decomposition techniques for linear and nonlinear stochastic programming
Resumo:
Une approche classique pour traiter les problèmes d’optimisation avec incertitude à deux- et multi-étapes est d’utiliser l’analyse par scénario. Pour ce faire, l’incertitude de certaines données du problème est modélisée par vecteurs aléatoires avec des supports finis spécifiques aux étapes. Chacune de ces réalisations représente un scénario. En utilisant des scénarios, il est possible d’étudier des versions plus simples (sous-problèmes) du problème original. Comme technique de décomposition par scénario, l’algorithme de recouvrement progressif est une des méthodes les plus populaires pour résoudre les problèmes de programmation stochastique multi-étapes. Malgré la décomposition complète par scénario, l’efficacité de la méthode du recouvrement progressif est très sensible à certains aspects pratiques, tels que le choix du paramètre de pénalisation et la manipulation du terme quadratique dans la fonction objectif du lagrangien augmenté. Pour le choix du paramètre de pénalisation, nous examinons quelques-unes des méthodes populaires, et nous proposons une nouvelle stratégie adaptive qui vise à mieux suivre le processus de l’algorithme. Des expériences numériques sur des exemples de problèmes stochastiques linéaires multi-étapes suggèrent que la plupart des techniques existantes peuvent présenter une convergence prématurée à une solution sous-optimale ou converger vers la solution optimale, mais avec un taux très lent. En revanche, la nouvelle stratégie paraît robuste et efficace. Elle a convergé vers l’optimalité dans toutes nos expériences et a été la plus rapide dans la plupart des cas. Pour la question de la manipulation du terme quadratique, nous faisons une revue des techniques existantes et nous proposons l’idée de remplacer le terme quadratique par un terme linéaire. Bien que qu’il nous reste encore à tester notre méthode, nous avons l’intuition qu’elle réduira certaines difficultés numériques et théoriques de la méthode de recouvrement progressif.
Resumo:
Les métaheuristiques sont très utilisées dans le domaine de l'optimisation discrète. Elles permettent d’obtenir une solution de bonne qualité en un temps raisonnable, pour des problèmes qui sont de grande taille, complexes, et difficiles à résoudre. Souvent, les métaheuristiques ont beaucoup de paramètres que l’utilisateur doit ajuster manuellement pour un problème donné. L'objectif d'une métaheuristique adaptative est de permettre l'ajustement automatique de certains paramètres par la méthode, en se basant sur l’instance à résoudre. La métaheuristique adaptative, en utilisant les connaissances préalables dans la compréhension du problème, des notions de l'apprentissage machine et des domaines associés, crée une méthode plus générale et automatique pour résoudre des problèmes. L’optimisation globale des complexes miniers vise à établir les mouvements des matériaux dans les mines et les flux de traitement afin de maximiser la valeur économique du système. Souvent, en raison du grand nombre de variables entières dans le modèle, de la présence de contraintes complexes et de contraintes non-linéaires, il devient prohibitif de résoudre ces modèles en utilisant les optimiseurs disponibles dans l’industrie. Par conséquent, les métaheuristiques sont souvent utilisées pour l’optimisation de complexes miniers. Ce mémoire améliore un procédé de recuit simulé développé par Goodfellow & Dimitrakopoulos (2016) pour l’optimisation stochastique des complexes miniers stochastiques. La méthode développée par les auteurs nécessite beaucoup de paramètres pour fonctionner. Un de ceux-ci est de savoir comment la méthode de recuit simulé cherche dans le voisinage local de solutions. Ce mémoire implémente une méthode adaptative de recherche dans le voisinage pour améliorer la qualité d'une solution. Les résultats numériques montrent une augmentation jusqu'à 10% de la valeur de la fonction économique.
Resumo:
Un résumé en français est également disponible.
Resumo:
L’insomnie, une condition fréquemment retrouvée dans la population, se caractérise d’abord par une difficulté à initier ou à maintenir le sommeil et/ou par des éveils précoces le matin ou encore par un sommeil non-réparateur. Lorsqu’elle n’est pas accompagnée par des troubles psychiatriques ou médicaux ou un autre trouble de sommeil et qu’elle perdure plus de 6 mois on parle alors d’insomnie primaire chronique. Selon certains, cette condition serait associée à un état d’hyperéveil caractérisé par une augmentation de l’activité autonome sympathique durant le sommeil et l’éveil. Le baroréflexe est un important mécanisme de contrôle à court terme des fluctuations de la tension artérielle (TA) et de la fréquence cardiaque agissant sur le cœur et les vaisseaux sanguins par l’entremise du système nerveux autonome. On appelle sensibilité baroréceptive (SBR) la capacité du baroréflexe de réagir et de contrôler les fluctuations de TA en modulant le rythme cardiaque. De manière générale, la SBR serait augmentée durant la nuit par rapport à la journée. Aussi, il semblerait que le baroréflexe soit impliqué dans le phénomène de baisse physiologique de la TA pendant la nuit. Or, des données de notre laboratoire ont démontré une augmentation de la TA systolique au cours de la nuit ainsi qu’une atténuation de la baisse nocturne de TA systolique chez des sujets avec insomnie primaire chronique comparé à des témoins bons dormeurs. De plus, il a été démontré que le baroréflexe était altéré de façon précoce dans plusieurs troubles cardiovasculaires et dans l’hypertension artérielle. Or, il semblerait que l’insomnie soit accompagnée d’un risque accru de développement de l’hypertension artérielle. Ces études semblent aller dans le sens d’une altération des mécanismes de régulation de la TA dans l’insomnie. Par ailleurs, une réduction de la SBR serait aussi impliquée dans des états associés à une augmentation de l’activité autonome sympathique. Ainsi, nous nous sommes demandé si le baroréflexe pouvait constituer un des mécanismes de contrôle de la TA qui serait altéré dans l’insomnie et pourrait être impliqué dans l’augmentation de l’activité sympathique qui semble accompagner l’insomnie. Jusqu’à présent, le baroréflexe reste inexploré dans l’insomnie. L’objectif principal de ce mémoire était d’évaluer de façon non-invasive la SBR à l’éveil et en sommeil chez 11 sujets atteints d’insomnie primaire chronique comparé à 11 témoins bons dormeurs. L’évaluation du baroréflexe a été effectuée de façon spontanée par la méthode de l’analyse en séquence et par le calcul du coefficient alpha obtenu par l’analyse spectrale croisée de l’intervalle RR et de la TA systolique. De façon concomitante, les paramètres de la variabilité de l’intervalle RR en sommeil et à l’éveil ont aussi été comparés chez ces mêmes sujets. Aucune différence significative n’a été notée au niveau des index de la SBR entre le groupe d’insomniaques et celui des bons dormeurs, à l’éveil ou en sommeil. Cependant, on observe des valeurs légèrement plus faibles de la SBR chez les insomniaques ayant mal dormi (efficacité de sommeil (ES) < 85%) comparés aux insomniaques ayant bien dormi (ES≥ 85%) à la nuit expérimentale durant l’éveil et en sommeil. Par ailleurs, aucune différence n’a été notée entre le groupe d’insomniaques et celui des bons dormeurs au niveau des paramètres de la variabilité RR considérés (intervalle RR, PNN50, LF et HF en valeurs normalisées). En effet, les insomniaques tout comme les bons dormeurs semblent présenter une variation normale de l’activité autonome en sommeil, telle que représentée par les paramètres de la variabilité RR. Ces résultats préliminaires semblent suggérer que les mécanismes du baroréflexe sont préservés chez les sujets atteints d’insomnie primaire chronique tels que diagnostiqués de manière subjective. Cependant, il est possible qu’une altération des mécanismes du baroréflexe ne se révèle chez les insomniaques que lorsque les critères objectifs d’une mauvaise nuit de sommeil sont présents.
Resumo:
Introduction : L’expansion palatine rapide assistée chirurgicalement (EPRAC) est une option de traitement privilégiée chez les patients ayant atteint la maturité squelettique et présentant une déficience transverse du maxillaire. L’effet bénéfique de l’EPRAC sur la fonction respiratoire est régulièrement mentionné, toutefois, encore peu d’études ont évalué son impact sur les voies aériennes supérieures. L’objectif de cette étude clinique prospective comparative consistait à évaluer les effets tridimensionnels de l’EPRAC sur la cavité nasale, le nasopharynx et l’oropharynx à l’aide de la tomodensitométrie. Méthodologie : L’échantillon était constitué de 14 patients (5 hommes, 9 femmes) dont l’âge moyen était de 23,0 ± 1,9 ans (16 ans 4 mois à 39 ans 7 mois). Tous ont été traités avec un appareil d’expansion de type Hyrax collé et l’expansion moyenne a été de 9,82 mm (7,5 - 12,0 mm). Tous ont eu une période de contention d’une année avant le début de tout autre traitement orthodontique. Une évaluation par tomodensitométrie volumique à faisceau conique a été réalisée aux temps T0 (initial), T1 (6 mois post-expansion) et T2 (1an post-expansion) et le volume des fosses nasales, du nasopharynx et de l’oropharynx ainsi que les dimensions de la zone de constriction maximale de l’oropharynx ont été mesurés sur les volumes tridimensionnels obtenus. Résultats : Les résultats radiologiques ont démontré une augmentation significative du volume des fosses nasales et du nasopharynx ainsi qu’une augmentation de la zone de constriction maximale de l’oropharynx à 6 mois post-expansion. Par la suite, une portion du gain enregistré pour ces trois paramètres était perdue à un an post-EPRAC sans toutefois retourner aux valeurs initiales. Aucun effet significatif sur le volume de l’oropharynx n’a été observé. De plus, aucune corrélation significative entre la quantité d’expansion réalisée et l’ensemble des données radiologiques n’a été observée. L’analyse de la corrélation intra-classe a démontré une excellente fiabilité intra-examinateur. Conclusions : L’EPRAC entraîne un changement significatif du volume de la cavité nasale et du nasopharynx. L’EPRAC ne modifie pas le volume de l’oropharynx, par contre, un effet significatif sur la zone de constriction maximale de l’oropharynx est noté. Les effets observés n’ont pas de corrélation avec le montant d’activation de la vis d’expansion.
Resumo:
Présentement, le diagnostic d’otite moyenne-interne chez le veau est basé sur la présence de signes cliniques appropriés ainsi que les tests diagnostiques tels que la radiographie et la tomodensitométrie. L’objectif de cette étude prospective était d’évaluer les valeurs prédictives de l’examen neurologique, l’examen otoscopique et le test des potentiels auditifs évoqués (PAE) dans le diagnostic d’otite moyenne-interne chez le veau, en utilisant la tomodensitométrie comme test standard. Le deuxième objectif était de définir les valeurs de référence pour le PAE chez le veau normal et d’en décrire les anomalies chez des veaux atteints d’otite moyenne-interne. Dix-sept veaux de race Holstein entre 5-7 semaines d’âge ont été inclus. Tous les veaux ont eu un examen neurologique, un examen otoscopique et une évaluation des PAEs. Les veaux ont été tranquillisés avec de la xylazine intraveineuse (0,05-0,15mg/kg) pour la tomodensitométrie des bulles tympaniques afin d’évaluer pour la présence d’otite moyenne-interne. Selon les résultats de la tomodensitométrie, 11 des 17 veaux étaient atteints avec otite moyenne, 4 de façon unilatérale et 7 bilatéralement. Cinq ondes ont été identifiées de façon constante sur les tracés des PAEs des 6 veaux normaux. Les valeurs positives prédictives pour le PAE, l’examen neurologique et l’examen otoscopique étaient 94,7%, 91,7% et 66,7% respectivement. D’un point de vue clinique, le test le plus fiable dans le diagnostic d’otite moyenne-interne chez le veau est le PAE. Les anomalies ont été observées au PAE avant le développement des signes neurologiques chez certains veaux.
Resumo:
Cette thèse présente des méthodes de traitement de données de comptage en particulier et des données discrètes en général. Il s'inscrit dans le cadre d'un projet stratégique du CRNSG, nommé CC-Bio, dont l'objectif est d'évaluer l'impact des changements climatiques sur la répartition des espèces animales et végétales. Après une brève introduction aux notions de biogéographie et aux modèles linéaires mixtes généralisés aux chapitres 1 et 2 respectivement, ma thèse s'articulera autour de trois idées majeures. Premièrement, nous introduisons au chapitre 3 une nouvelle forme de distribution dont les composantes ont pour distributions marginales des lois de Poisson ou des lois de Skellam. Cette nouvelle spécification permet d'incorporer de l'information pertinente sur la nature des corrélations entre toutes les composantes. De plus, nous présentons certaines propriétés de ladite distribution. Contrairement à la distribution multidimensionnelle de Poisson qu'elle généralise, celle-ci permet de traiter les variables avec des corrélations positives et/ou négatives. Une simulation permet d'illustrer les méthodes d'estimation dans le cas bidimensionnel. Les résultats obtenus par les méthodes bayésiennes par les chaînes de Markov par Monte Carlo (CMMC) indiquent un biais relatif assez faible de moins de 5% pour les coefficients de régression des moyennes contrairement à ceux du terme de covariance qui semblent un peu plus volatils. Deuxièmement, le chapitre 4 présente une extension de la régression multidimensionnelle de Poisson avec des effets aléatoires ayant une densité gamma. En effet, conscients du fait que les données d'abondance des espèces présentent une forte dispersion, ce qui rendrait fallacieux les estimateurs et écarts types obtenus, nous privilégions une approche basée sur l'intégration par Monte Carlo grâce à l'échantillonnage préférentiel. L'approche demeure la même qu'au chapitre précédent, c'est-à-dire que l'idée est de simuler des variables latentes indépendantes et de se retrouver dans le cadre d'un modèle linéaire mixte généralisé (GLMM) conventionnel avec des effets aléatoires de densité gamma. Même si l'hypothèse d'une connaissance a priori des paramètres de dispersion semble trop forte, une analyse de sensibilité basée sur la qualité de l'ajustement permet de démontrer la robustesse de notre méthode. Troisièmement, dans le dernier chapitre, nous nous intéressons à la définition et à la construction d'une mesure de concordance donc de corrélation pour les données augmentées en zéro par la modélisation de copules gaussiennes. Contrairement au tau de Kendall dont les valeurs se situent dans un intervalle dont les bornes varient selon la fréquence d'observations d'égalité entre les paires, cette mesure a pour avantage de prendre ses valeurs sur (-1;1). Initialement introduite pour modéliser les corrélations entre des variables continues, son extension au cas discret implique certaines restrictions. En effet, la nouvelle mesure pourrait être interprétée comme la corrélation entre les variables aléatoires continues dont la discrétisation constitue nos observations discrètes non négatives. Deux méthodes d'estimation des modèles augmentés en zéro seront présentées dans les contextes fréquentiste et bayésien basées respectivement sur le maximum de vraisemblance et l'intégration de Gauss-Hermite. Enfin, une étude de simulation permet de montrer la robustesse et les limites de notre approche.
Resumo:
UNE EXPOSITION NÉONATALE À L’OXYGÈNE MÈNE À DES MODIFICATIONS DE LA FONCTION MITOCHONDRIALE CHEZ LE RAT ADULTE Introduction: L’exposition à l’oxygène (O2) des ratons nouveau-nés a des conséquences à l’âge adulte dont une hypertension artérielle (HTA), une dysfonction vasculaire, une néphropénie et des indices de stress oxydant. En considérant que les reins sont encore en développement actif lors des premiers jours après la naissance chez les rats, jouent un rôle clé dans le développement de l’hypertension et qu’une dysfonction mitochondriale est associé à une augmentation du stress oxydant, nous postulons que les conditions délétères néonatales peuvent avoir un impact significatif au niveau rénal sur la modulation de l’expression de protéines clés du fonctionnement mitochondrial et une production mitochondriale excessive d’espèces réactives de l’ O2. Méthodes: Des ratons Sprague-Dawley sont exposés à 80% d’O2 (H) ou 21% O2 (Ctrl) du 3e au 10e jr de vie. En considérant que plusieurs organes des rats sont encore en développement actif à la naissance, ces rongeurs sont un modèle reconnu pour étudier les complications d’une hyperoxie néonatale, comme celles liées à une naissance prématurée chez l’homme. À 4 et à 16 semaines, les reins sont prélevés et les mitochondries sont extraites suivant une méthode d’extraction standard, avec un tampon contenant du sucrose 0.32 M et différentes centrifugations. L’expression des protéines mitochondriales a été mesurée par Western blot, tandis que la production d’ H202 et les activités des enzymes clés du cycle de Krebs ont été évaluées par spectrophotométrie. Les résultats sont exprimés par la moyenne ± SD. Résultats: Les rats mâles H de 16 semaines (n=6) présentent une activité de citrate synthase (considéré standard interne de l’expression protéique et de l’abondance mitochondriales) augmentée (12.4 ± 8.4 vs 4.1 ± 0.5 μmole/mL/min), une diminution de l’activité d’aconitase (enzyme sensible au redox mitochondrial) (0.11 ± 0.05 vs 0.20 ± 0.04 μmoles/min/mg mitochondrie), ainsi qu’une augmentation dans la production de H202 (7.0 ± 1.3 vs 5.4 ± 0.8 ρmoles/mg protéines mitochondriales) comparativement au groupe Ctrl (n=6 mâles et 4 femelles). Le groupe H (vs Ctrl) présente également une diminution dans l’expression de peroxiredoxin-3 (Prx3) (H 0.61±0.06 vs. Ctrl 0.78±0.02 unité relative, -23%; p<0.05), une protéine impliquée dans l’élimination d’ H202, de l’expression du cytochrome C oxidase (Complexe IV) (H 1.02±0.04 vs. Ctrl 1.20±0.02 unité relative, -15%; p<0.05), une protéine de la chaine de respiration mitochondriale, tandis que l’expression de la protéine de découplage (uncoupling protein)-2 (UCP2), impliquée dans la dispersion du gradient proton, est significativement augmentée (H 1.05±0.02 vs. Ctrl 0.90±0.03 unité relative, +17%; p<0.05). Les femelles H (n=6) (vs Ctrl, n=6) de 16 semaines démontrent une augmentation significative de l’activité de l’aconitase (0.33±0.03 vs 0.17±0.02 μmoles/min/mg mitochondrie), de l’expression de l’ATP synthase sous unité β (H 0.73±0.02 vs. Ctrl 0.59±0.02 unité relative, +25%; p<0.05) et de l’expression de MnSOD (H 0.89±0.02 vs. Ctrl 0.74±0.03 unité relative, +20%; p<0.05) (superoxide dismutase mitochondriale, important antioxidant), tandis que l’expression de Prx3 est significativement réduite (H 1.1±0.07 vs. Ctrl 0.85±0.01 unité relative, -24%; p<0.05). À 4 semaines, les mâles H (vs Ctrl) présentent une augmentation significative de l’expression de Prx3 (H 0.72±0.03 vs. Ctrl 0.56±0.04 unité relative, +31%; p<0.05) et les femelles présentent une augmentation significative de l’expression d’UCP2 (H 1.22±0.05 vs. Ctrl 1.03±0.04 unité relative, +18%; p<0.05) et de l’expression de MnSOD (H 1.36±0.01 vs. 1.19±0.06 unité relative, +14%; p<0.05). Conclusions: Une exposition néonatale à l’O2 chez le rat adulte mène à des indices de dysfonction mitochondriale dans les reins adultes, associée à une augmentation dans la production d’espèces réactives de l’oxygène, suggérant que ces modifications mitochondriales pourraient jouer un rôle dans l’hypertension artérielle et d’un stress oxydant, et par conséquent, être un facteur possible dans la progression vers des maladies cardiovasculaires. Mots-clés: Mitochondries, Reins, Hypertension, Oxygène, Stress Oxydant, Programmation
Resumo:
La tolérance immunitaire dépend de la distinction entre le soi et le non soi par le système immunitaire. Un bris dans la tolérance immunitaire mène à l'auto-immunité, qui peut provoquer la destruction des organes, des glandes, des articulations ou du système nerveux central. Le diabète auto-immun, également connu sous le nom diabète juvénile et diabète de type 1, résulte d'une attaque auto-immune sur les cellules β pancréatiques sécrétrices d’insuline, localisées au niveau des îlots de Langerhans du pancréas. Bien que le diabète auto-immun soit traitable par une combinaison d’injections quotidiennes d’insuline d’origine exogène, de régime et d'exercices, beaucoup de complications chroniques peuvent se manifester chez les patients, y compris, mais non limitées à, la cécité, les maladies cardiovasculaires, l’insuffisance rénale et l'amputation. En raison des nombreuses complications liées au diabète auto-immun à long terme, la recherche continue afin de mieux comprendre tous les facteurs impliqués dans la progression de la maladie dans le but de développer de nouvelles thérapies qui empêcheront, renverseront et/ou traiteront cette maladie. Un rôle primordial dans la génération et l'entretien de la tolérance immunitaire a été attribué au nombre et à la fonction des sous-populations de cellules régulatrices. Une de ces populations est constituée de cellules T CD4-CD8- (double négatives, DN), qui ont été étudiées chez la souris et l'humain pour leur contribution à la tolérance périphérique, à la prévention des maladies et pour leur potentiel associé à la thérapie cellulaire. En effet, les cellules de T DN sont d'intérêt thérapeutique parce qu'elles montrent un potentiel immunorégulateur antigène-spécifique dans divers cadres expérimentaux, y compris la prévention du diabète auto-immun. D’ailleurs, en utilisant un système transgénique, nous avons démontré que les souris prédisposées au diabète auto-immun présentent peu de cellules T DN, et que ce phénotype contribue à la susceptibilité au diabète auto-immun. En outre, un transfert des cellules T DN est suffisant pour empêcher la progression vers le diabète chez les souris prédisposées au diabète auto-immun. Ces résultats suggèrent que les cellules T DN puissent présenter un intérêt thérapeutique pour les patients diabétiques. Cependant, nous devons d'abord valider ces résultats en utilisant un modèle non-transgénique, qui est plus physiologiquement comparable à l'humain. L'objectif principal de cette thèse est de définir la fonction immunorégulatrice des cellules T DN, ainsi que le potentiel thérapeutique de celles-ci dans la prévention du diabète auto-immun chez un modèle non-transgénique. Dans cette thèse, on démontre que les souris résistantes au diabète auto-immun présentent une proportion et nombre absolu plus élevés de cellules T DN non-transgéniques, lorsque comparées aux souris susceptibles. Cela confirme une association entre le faible nombre de cellules T DN et la susceptibilité à la maladie. On observe que les cellules T DN éliminent les cellules B activées in vitro par une voie dépendante de la voie perforine et granzyme, où la fonction des cellules T DN est équivalente entre les souris résistantes et prédisposées au diabète auto-immun. Ces résultats confirment que l'association au diabète auto-immun est due à une insuffisance en terme du nombre de cellules T DN, plutôt qu’à une déficience fonctionnelle. On démontre que les cellules T DN non-transgéniques éliminent des cellules B chargées avec des antigènes d'îlots, mais pas des cellules B chargées avec un antigène non reconnu, in vitro. Par ailleurs, on établit que le transfert des cellules T DN activées peut empêcher le développement du diabète auto-immun dans un modèle de souris non-transgénique. De plus, nous observons que les cellules T DN migrent aux îlots pancréatiques, et subissent une activation et une prolifération préférentielles au niveau des ganglions pancréatiques. D'ailleurs, le transfert des cellules T DN entraîne une diminution d'auto-anticorps spécifiques de l'insuline et de cellules B de centres germinatifs directement dans les îlots, ce qui corrèle avec les résultats décrits ci-dessus. Les résultats présentés dans cette thèse permettent de démontrer la fonction des cellules T DN in vitro et in vivo, ainsi que leur potentiel lié à la thérapie cellulaire pour le diabète auto-immun.
Resumo:
L’objet de cette thèse est l’élaboration d’un modèle logique de mesure du maintien des valeurs, ainsi que son opérationnalisation afin d’entreprendre l’évaluation de la performance des systèmes de santé. Le maintien des valeurs est l’une des quatre fonctions de la théorie de l’action sociale de T.Parsons permettant d’analyser les systèmes d’action. Les autres fonctions sont l’adaptation, la production et l’atteinte des buts. Cette théorie est la base du modèle EGIPSS (évaluation globale et intégrée de la performance des systèmes de santé), dans lequel cette thèse s’insère. La fonction étudiée correspond, dans l’oeuvre de T.Parsons, au sous-système culturel. Elle renvoie à l’intangible, soit à l’univers symbolique par lequel l’action prend son sens et les fonctions du système s’articulent. Le modèle logique de mesure du maintien des valeurs est structuré autour de deux concepts principaux, les valeurs individuelles et organisationnelles et la qualité de vie au travail. À travers les valeurs individuelles et organisationnelles, nous mesurons la hiérarchie et l’intensité des valeurs, ainsi que le niveau de concordance interindividuelle et le degré de congruence entre les valeurs individuelles et organisationnelles. La qualité de vie au travail est composée de plusieurs concepts permettant d’analyser et d’évaluer l’environnement de travail, le climat organisationnel, la satisfaction au travail, les réactions comportementales et l’état de santé des employés. La mesure de ces différents aspects a donné lieu à la conception de trois questionnaires et de trente indicateurs. Ma thèse présente, donc, chacun des concepts sélectionnés et leurs articulations, ainsi que les outils de mesure qui ont été construits afin d’évaluer la dimension du maintien des valeurs. Enfin, nous exposons un exemple d’opérationnalisation de ce modèle de mesure appliqué à deux hôpitaux dans la province du Mato Grosso du Sud au Brésil. Cette thèse se conclut par une réflexion sur l’utilisation de l’évaluation comme outil de gestion soutenant l’amélioration de la performance et l’imputabilité. Ce projet comportait un double enjeu. Tout d’abord, la conceptualisation de la dimension du maintien des valeurs à partir d’une littérature abondante, mais manquant d’intégration théorique, puis la création d’outils de mesure permettant de saisir autant les aspects objectifs que subjectifs des valeurs et de la qualité de vie au travail. En effet, on trouve dans la littérature de nombreuses disciplines et de multiples courants théoriques tels que la psychologie industrielle et organisationnelle, la sociologie, les sciences infirmières, les théories sur le comportement organisationnel, la théorie des organisations, qui ont conçu des modèles pour analyser et comprendre les perceptions, les attitudes et les comportements humains dans les organisations. Ainsi, l’intérêt scientifique de ce projet découle de la création d’un modèle dynamique et intégrateur offrant une synthèse des différents champs théoriques abordant la question de l’interaction entre les perceptions individuelles et collectives au travail, les conditions objectives de travail et leurs influences sur les attitudes et les comportements au travail. D’autre part, ce projet revêt un intérêt opérationnel puisqu’il vise à fournir aux décideurs du système de santé des connaissances et données concernant un aspect de la performance fortement négligé par la plupart des modèles internationaux d’évaluation de la performance.
Resumo:
Introduction : Les accéléromètres sont actuellement les appareils les plus utilisés pour mesurer le niveau d’activité physique, et ce, parce qu'ils évaluent les niveaux d'activité physique de façon objective. Toutefois, les mouvements humains sont difficiles à mesurer, et de nombreuses limitations doivent être prises en considération pour la bonne utilisation des accéléromètres. Les études présentées s’intéressent donc à la validité de la fonction podomètre des accéléromètres ainsi qu’à la validation de la composante accéléromètre d’un nouvel appareil multicapteur (SenseDoc). Méthode : Les sujets ayant participé à la première étude, qui consistait en la validation de la fonction podomètre des accéléromètres, ont marché sur un tapis roulant à trois vitesses différentes (2,5 km/h, 3,5 km/h et 4,8 km/h) pendant 5 minutes par palier. Un accéléromètre (ActiGraph GT3X) porté à la ceinture a enregistré le nombre de pas tandis qu'une caméra a enregistré la marche des participants. Pour la seconde étude, les participants portaient un accéléromètre Actigraph et un SenseDoc à la hanche. Les données brutes des accéléromètres et la mesure de la consommation d’oxygène par calorimétrie indirecte ont été mesurées lors de 14 activités réalisées en laboratoire allant de sédentaires à vigoureuses. Résultats : La première étude indique que les accéléromètres ont détecté seulement 53 % des pas à 2,5 km/h, 82 % à 3,5 km/h et 91 % à 4,8 km/h pour les personnes non obèses. Pour les personnes obèses, l'accéléromètre a détecté 47 % des pas à 2.5 km/h, 67 % à 3.5 km/h et 100 % à 4.8 km/h, des résultats significativement différents des personnes non obèses. La seconde étude confirme pour sa part que le SenseDoc est un outil valide de mesure du niveau d’activité physique. Les accéléromètres possèdent une bonne capacité prédictive de la dépense énergétique avec des valeurs de R carré de 0,84 et 0,80 respectivement pour l'Actigraph et le SenseDoc. Conclusion : À vitesse de marche lente, les accéléromètres sous-estiment le nombre de pas, et ce, dans une plus large mesure chez les personnes obèses que chez les personnes non obèses. Également, une méthode valide et transparente de transformation de données brutes d’accélérométrie a été divulguée dans l’étude avec le SenseDoc. Les travaux présentés dans ce mémoire visent à améliorer l’utilisation en milieu clinique et en recherche des accéléromètres et ouvrent la voie à une plus grande uniformité entre les études utilisant différents types d’accéléromètres.
Resumo:
Contexte & Objectifs : La manométrie perfusée conventionnelle et la manométrie haute résolution (HRM) ont permis le développement d’une variété de paramètres pour mieux comprendre la motilité de l'œsophage et quantifier les caractéristiques de la jonction œsophago-gastrique (JOG). Cependant, l'anatomie de la JOG est complexe et les enregistrements de manométrie détectent à la fois la pression des structures intrinsèques et des structures extrinsèques à l'œsophage. Ces différents composants ont des rôles distincts au niveau de la JOG. Les pressions dominantes ainsi détectées au niveau de la JOG sont attribuables au sphincter œsophagien inférieur (SOI) et aux piliers du diaphragme (CD), mais aucune des technologies manométriques actuelles n’est capable de distinguer ces différents composants de la JOG. Lorsqu’on analyse les caractéristiques de la JOG au repos, celle ci se comporte avant tout comme une barrière antireflux. Les paramètres manométriques les plus couramment utilisés dans ce but sont la longueur de la JOG et le point d’inversion respiratoire (RIP), défini comme le lieu où le pic de la courbe de pression inspiratoire change de positif (dans l’abdomen) à négatif (dans le thorax), lors de la classique manœuvre de « pull-through ». Cependant, l'importance de ces mesures reste marginale comme en témoigne une récente prise de position de l’American Gastroenterology Association Institute (AGAI) (1) qui concluait que « le rôle actuel de la manométrie dans le reflux gastro-œsophagien (RGO) est d'exclure les troubles moteurs comme cause des symptômes présentés par la patient ». Lors de la déglutition, la mesure objective de la relaxation de la JOG est la pression de relaxation intégrée (IRP), qui permet de faire la distinction entre une relaxation normale et une relaxation anormale de la JOG. Toutefois, puisque la HRM utilise des pressions moyennes à chaque niveau de capteurs, certaines études de manométrie laissent suggérer qu’il existe une zone de haute pression persistante au niveau de la JOG même si un transit est mis en évidence en vidéofluoroscopie. Récemment, la manométrie haute résolution « 3D » (3D-HRM) a été développée (Given Imaging, Duluth, GA) avec le potentiel de simplifier l'évaluation de la morphologie et de la physiologie de la JOG. Le segment « 3D » de ce cathéter de HRM permet l'enregistrement de la pression à la fois de façon axiale et radiale tout en maintenant une position fixe de la sonde, et évitant ainsi la manœuvre de « pull-through ». Par conséquent, la 3D-HRM devrait permettre la mesure de paramètres importants de la JOG tels que sa longueur et le RIP. Les données extraites de l'enregistrement fait par 3D-HRM permettraient également de différencier les signaux de pression attribuables au SOI des éléments qui l’entourent. De plus, l’enregistrement des pressions de façon radiaire permettrait d’enregistrer la pression minimale de chaque niveau de capteurs et devrait corriger cette zone de haute pression parfois persistante lors la déglutition. Ainsi, les objectifs de ce travail étaient: 1) de décrire la morphologie de la JOG au repos en tant que barrière antireflux, en comparant les mesures effectuées avec la 3D-HRM en temps réel, par rapport à celle simulées lors d’une manœuvre de « pull-through » et de déterminer quelles sont les signatures des pressions attribuables au SOI et au diaphragme; 2) d’évaluer la relaxation de la JOG pendant la déglutition en testant l'hypothèse selon laquelle la 3D-HRM permet le développement d’un nouveau paradigme (appelé « 3D eSleeve ») pour le calcul de l’IRP, fondé sur l’utilisation de la pression radiale minimale à chaque niveau de capteur de pression le long de la JOG. Ce nouveau paradigme sera comparé à une étude de transit en vidéofluoroscopie pour évaluer le gradient de pression à travers la JOG. Méthodes : Nous avons utilisé un cathéter 3D-HRM, qui incorpore un segment dit « 3D » de 9 cm au sein d’un cathéter HRM par ailleurs standard. Le segment 3D est composé de 12 niveaux (espacés de 7.5mm) de 8 capteurs de pression disposés radialement, soit un total de 96 capteurs. Neuf volontaires ont été étudiés au repos, où des enregistrements ont été effectués en temps réel et pendant une manœuvre de « pull-through » du segment 3D (mobilisation successive du cathéter de 5 mm, pour que le segment 3D se déplace le long de la JOG). Les mesures de la longueur du SOI et la détermination du RIP ont été réalisées. La longueur de la JOG a été mesurée lors du « pull-through » en utilisant 4 capteurs du segment 3D dispersés radialement et les marges de la JOG ont été définies par une augmentation de la pression de 2 mmHg par rapport à la pression gastrique ou de l’œsophage. Pour le calcul en temps réel, les limites distale et proximale de la JOG ont été définies par une augmentation de pression circonférentielle de 2 mmHg par rapport à la pression de l'estomac. Le RIP a été déterminée, A) dans le mode de tracé conventionnel avec la méthode du « pull-through » [le RIP est la valeur moyenne de 4 mesures] et B) en position fixe, dans le mode de représentation topographique de la pression de l’œsophage, en utilisant l’outil logiciel pour déterminer le point d'inversion de la pression (PIP). Pour l'étude de la relaxation de la JOG lors de la déglutition, 25 volontaires ont été étudiés et ont subi 3 études de manométrie (10 déglutitions de 5ml d’eau) en position couchée avec un cathéter HRM standard et un cathéter 3D-HRM. Avec la 3D-HRM, l’analyse a été effectuée une fois avec le segment 3D et une fois avec une partie non 3D du cathéter (capteurs standard de HRM). Ainsi, pour chaque individu, l'IRP a été calculée de quatre façons: 1) avec la méthode conventionnelle en utilisant le cathéter HRM standard, 2) avec la méthode conventionnelle en utilisant le segment standard du cathéter 3D-HRM, 3) avec la méthode conventionnelle en utilisant le segment « 3D » du cathéter 3D-HRM, et 4) avec le nouveau paradigme (3D eSleeve) qui recueille la pression minimale de chaque niveau de capteurs (segment 3D). Quatorze autres sujets ont subi une vidéofluoroscopie simultanée à l’étude de manométrie avec le cathéter 3D-HRM. Les données de pression ont été exportés vers MATLAB ™ et quatre pressions ont été mesurées simultanément : 1) la pression du corps de l’œsophage, 2cm au-dessus de la JOG, 2) la pression intragastrique, 3) la pression radiale moyenne de la JOG (pression du eSleeve) et 4) la pression de la JOG en utilisant la pression minimale de chaque niveau de capteurs (pression du 3D eSleeve). Ces données ont permis de déterminer le temps permissif d'écoulement du bolus (FPT), caractérisé par la période au cours de laquelle un gradient de pression existe à travers la JOG (pression œsophagienne > pression de relaxation de la JOG > pression gastrique). La présence ou l'absence du bolus en vidéofluoroscopie et le FPT ont été codés avec des valeurs dichotomiques pour chaque période de 0,1 s. Nous avons alors calculé la sensibilité et la spécificité correspondant à la valeur du FPT pour la pression du eSleeve et pour la pression du 3D eSleeve, avec la vidéofluoroscopie pour référence. Résultats : Les enregistrements avec la 3D-HRM laissent suggérer que la longueur du sphincter évaluée avec la méthode du « pull-through » était grandement exagéré en incorporant dans la mesure du SOI les signaux de pression extrinsèques à l’œsophage, asymétriques et attribuables aux piliers du diaphragme et aux structures vasculaires. L’enregistrement en temps réel a permis de constater que les principaux constituants de la pression de la JOG au repos étaient attribuables au diaphragme. L’IRP calculé avec le nouveau paradigme 3D eSleeve était significativement inférieur à tous les autres calculs d'IRP avec une limite supérieure de la normale de 12 mmHg contre 17 mmHg pour l’IRP calculé avec la HRM standard. La sensibilité (0,78) et la spécificité (0,88) du 3D eSleeve étaient meilleurs que le eSleeve standard (0,55 et 0,85 respectivement) pour prédire le FPT par rapport à la vidéofluoroscopie. Discussion et conclusion : Nos observations suggèrent que la 3D-HRM permet l'enregistrement en temps réel des attributs de la JOG, facilitant l'analyse des constituants responsables de sa fonction au repos en tant que barrière antireflux. La résolution spatiale axiale et radiale du segment « 3D » pourrait permettre de poursuivre cette étude pour quantifier les signaux de pression de la JOG attribuable au SOI et aux structures extrinsèques (diaphragme et artéfacts vasculaires). Ces attributs du cathéter 3D-HRM suggèrent qu'il s'agit d'un nouvel outil prometteur pour l'étude de la physiopathologie du RGO. Au cours de la déglutition, nous avons évalué la faisabilité d’améliorer la mesure de l’IRP en utilisant ce nouveau cathéter de manométrie 3D avec un nouveau paradigme (3D eSleeve) basé sur l’utilisation de la pression radiale minimale à chaque niveau de capteurs de pression. Nos résultats suggèrent que cette approche est plus précise que celle de la manométrie haute résolution standard. La 3D-HRM devrait certainement améliorer la précision des mesures de relaxation de la JOG et cela devrait avoir un impact sur la recherche pour modéliser la JOG au cours de la déglutition et dans le RGO.