20 resultados para Column liquid chromatography-diode array detection

em Université de Montréal, Canada


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Ketamine is widely used in medicine in combination with several benzodiazepines including midazolam. The objectives of this study were to develop a novel HPLC-MS/SRM method capable of quantifying ketamine and norketamine using an isotopic dilution strategy in biological matrices and study the formation of norketamine, the principal metabolite of ketamine with and without the presence of midazolam, a well-known CYP3A substrate. The chromatographic separation was achieved using a Thermo Betasil Phenyl 100 x 2 mm column combined with an isocratic mobile phase composed of acetonitrile, methanol, water and formic acid (60:20:20:0.4) at a flow rate of 300 μL/min. The mass spectrometer was operating in selected reaction monitoring mode and the analytical range was set at 0.05–50 μM. The precision (%CV) and accuracy (%NOM) observed were ranging from 3.9–7.8 and 95.9.2–111.1% respectively. The initial rate of formation of norketamine was determined using various ketamine concentration and Km values of 18.4 μM, 13.8 μM and 30.8 μM for rat, dog and human liver S9 fractions were observed respectively. The metabolic stability of ketamine on liver S9 fractions was significantly higher in human (T1/2 = 159.4 min) compared with rat (T1/2 = 12.6 min) and dog (T1/2 = 7.3 min) liver S9 fractions. Moreover significantly lower IC50 and Ki values observed in human compared with rat and dog liver S9 fractions. Experiments with cDNA expressed CYP3A enzymes showed the formation of norketamine is mediated by CYP3A but results suggest an important contribution from others isoenzymes, most likely CYP2C particularly in rat.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Tachykinin and opioid peptides play a central role in pain transmission, modulation and inhibition. The treatment of pain is very important in medicine and many studies using NK1 receptor antagonists failed to show significant analgesic effects in humans. Recent investigations suggest that both pronociceptive tachykinins and the analgesic opioid systems are important for normal pain sensation. The analysis of opioid peptides in Tac1-/- spinal cord tissues offers a great opportunity to verify the influence of the tachykinin system on specific opioid peptides. The objectives of this study were to develop a HPLC–MS/MRM assay to quantify targeted peptides in spinal cord tissues. Secondly, we wanted to verify if the Tac1-/- mouse endogenous opioid system is hampered and therefore affect significantly the pain modulatory pathways. Targeted neuropeptides were analyzed by high performance liquid chromatography linear ion trap mass spectrometry. Our results reveal that EM-2, Leu-Enk and Dyn A were down-regulated in Tac1-/- spinal cord tissues. Interestingly, Dyn A was almost 3 fold down-regulated (p < 0.0001). No significant concentration differences were observed in mouse Tac1-/- spinal cords for Met-Enk and CGRP. The analysis of Tac1-/- mouse spinal cords revealed noteworthy decreases of EM-2, Leu-Enk and Dyn A concentrations which strongly suggest a significant impact on the endogenous pain-relieving mechanisms. These observations may have insightful impact on future analgesic drug developments and therapeutic strategies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

La fumée du tabac est un aérosol extrêmement complexe constitué de milliers de composés répartis entre la phase particulaire et la phase vapeur. Il a été démontré que les effets toxicologiques de cette fumée sont associés aux composés appartenant aux deux phases. Plusieurs composés biologiquement actifs ont été identifiés dans la fumée du tabac; cependant, il n’y a pas d’études démontrant la relation entre les réponses biologiques obtenues via les tests in vitro ou in vivo et les composés présents dans la fumée entière du tabac. Le but de la présente recherche est de développer des méthodes fiables et robustes de fractionnement de la fumée à l’aide de techniques de séparation analytique et de techniques de détection combinés à des essais in vitro toxicologiques. Une étude antérieure réalisée par nos collaborateurs a démontré que, suite à l’étude des produits de combustion de douze principaux composés du tabac, l’acide chlorogénique s’est avéré être le composé le plus cytotoxique selon les test in vitro du micronoyau. Ainsi, dans cette étude, une méthode par chromatographie préparative en phase liquide a été développée dans le but de fractionner les produits de combustion de l’acide chlorogénique. Les fractions des produits de combustion de l’acide chlorogénique ont ensuite été testées et les composés responsables de la toxicité de l’acide chlorogénique ont été identifiés. Le composé de la sous-fraction responsable en majeure partie de la cytoxicité a été identifié comme étant le catéchol, lequel fut confirmé par chromatographie en phase liquide/ spectrométrie de masse à temps de vol. Des études récentes ont démontré les effets toxicologiques de la fumée entière du tabac et l’implication spécifique de la phase vapeur. C’est pourquoi notre travail a ensuite été focalisé principalement à l’analyse de la fumée entière. La machine à fumer Borgwaldt RM20S® utilisée avec les chambres d’exposition cellulaire de British American Tobacco permettent l’étude in vitro de l’exposition de cellules à différentes concentrations de fumée entière du tabac. Les essais biologiques in vitro ont un degré élevé de variabilité, ainsi, il faut prendre en compte toutes les autres sources de variabilité pour évaluer avec précision la finalité toxicologique de ces essais; toutefois, la fiabilité de la génération de la fumée de la machine n’a jamais été évaluée jusqu’à maintenant. Nous avons donc déterminé la fiabilité de la génération et de la dilution (RSD entre 0,7 et 12 %) de la fumée en quantifiant la présence de deux gaz de référence (le CH4 par détection à ionisation de flamme et le CO par absorption infrarouge) et d’un composé de la phase particulaire, le solanesol (par chromatographie en phase liquide à haute performance). Ensuite, la relation entre la dose et la dilution des composés de la phase vapeur retrouvée dans la chambre d’exposition cellulaire a été caractérisée en utilisant une nouvelle technique d’extraction dite par HSSE (Headspace Stir Bar Sorptive Extraction) couplée à la chromatographie en phase liquide/ spectrométrie de masse. La répétabilité de la méthode a donné une valeur de RSD se situant entre 10 et 13 % pour cinq des composés de référence identifiés dans la phase vapeur de la fumée de cigarette. La réponse offrant la surface maximale d’aire sous la courbe a été obtenue en utilisant les conditions expérimentales suivantes : intervalle de temps d’exposition/ désorption de 10 0.5 min, température de désorption de 200°C pour 2 min et température de concentration cryogénique (cryofocussing) de -75°C. La précision de la dilution de la fumée est linéaire et est fonction de l’abondance des analytes ainsi que de la concentration (RSD de 6,2 à 17,2 %) avec des quantités de 6 à 450 ng pour les composés de référence. Ces résultats démontrent que la machine à fumer Borgwaldt RM20S® est un outil fiable pour générer et acheminer de façon répétitive et linéaire la fumée de cigarette aux cultures cellulaires in vitro. Notre approche consiste en l’élaboration d’une méthodologie permettant de travailler avec un composé unique du tabac, pouvant être appliqué à des échantillons plus complexes par la suite ; ex : la phase vapeur de la fumée de cigarette. La méthodologie ainsi développée peut potentiellement servir de méthode de standardisation pour l’évaluation d’instruments ou de l’identification de produits dans l’industrie de tabac.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Les agents anti-infectieux sont utilisés pour traiter ou prévenir les infections chez les humains, les animaux, les insectes et les plantes. L’apparition de traces de ces substances dans les eaux usées, les eaux naturelles et même l’eau potable dans plusieurs pays du monde soulève l’inquiétude de la communauté scientifique surtout à cause de leur activité biologique. Le but de ces travaux de recherche a été d’étudier la présence d’anti-infectieux dans les eaux environnementales contaminées (c.-à-d. eaux usées, eaux naturelles et eau potable) ainsi que de développer de nouvelles méthodes analytiques capables de quantifier et confirmer leur présence dans ces matrices. Une méta-analyse sur l’occurrence des anti-infectieux dans les eaux environnementales contaminées a démontré qu’au moins 68 composés et 10 de leurs produits de transformation ont été quantifiés à ce jour. Les concentrations environnementales varient entre 0.1 ng/L et 1 mg/L, selon le composé, la matrice et la source de contamination. D’après cette étude, les effets nuisibles des anti-infectieux sur le biote aquatique sont possibles et ces substances peuvent aussi avoir un effet indirect sur la santé humaine à cause de sa possible contribution à la dissémination de la résistance aux anti-infecteiux chez les bactéries. Les premiers tests préliminaires de développement d’une méthode de détermination des anti-infectieux dans les eaux usées ont montré les difficultés à surmonter lors de l’extraction sur phase solide (SPE) ainsi que l’importance de la sélectivité du détecteur. On a décrit une nouvelle méthode de quantification des anti-infectieux utilisant la SPE en tandem dans le mode manuel et la chromatographie liquide couplée à la spectrométrie de masse en tandem (LC-MS/MS). Les six anti-infectieux ciblés (sulfaméthoxazole, triméthoprime, ciprofloxacin, levofloxacin, clarithromycin et azithromycin) ont été quantifiés à des concentrations entre 39 et 276 ng/L dans les échantillons d’affluent et d’effluent provenant d’une station d’épuration appliquant un traitement primaire et physico- chimique. Les concentrations retrouvées dans les effluents indiquent que la masse moyenne totale de ces substances, déversées hebdomadairement dans le fleuve St. Laurent, était de ~ 2 kg. En vue de réduire le temps total d’analyse et simplifier les manipulations, on a travaillé sur une nouvelle méthode de SPE couplée-LC-MS/MS. Cette méthode a utilisé une technique de permutation de colonnes pour préconcentrer 1.00 mL d’échantillon dans une colonne de SPE couplée. La performance analytique de la méthode a permis la quantification des six anti-infectieux dans les eaux usées municipales et les limites de détection étaient du même ordre de grandeur (13-60 ng/L) que les méthodes basées sur la SPE manuelle. Ensuite, l’application des colonnes de SPE couplée de chromatographie à débit turbulent pour la préconcentration de six anti-infectieux dans les eaux usées a été explorée pour diminuer les effets de matrice. Les résultats obtenus ont indiqué que ces colonnes sont une solution de réchange intéressante aux colonnes de SPE couplée traditionnelles. Finalement, en vue de permettre l’analyse des anti-infectieux dans les eaux de surface et l’eau potable, une méthode SPE couplée-LC-MS/MS utilisant des injections de grand volume (10 mL) a été développée. Le volume de fuite de plusieurs colonnes de SPE couplée a été estimé et la colonne ayant la meilleure rétention a été choisie. Les limites de détection et de confirmation de la méthode ont été entre 1 à 6 ng/L. L’analyse des échantillons réels a démontré que la concentration des trois anti-infectieux ciblés (sulfaméthoxazole, triméthoprime et clarithromycine) était au dessous de la limite de détection de la méthode. La mesure des masses exactes par spectrométrie de masse à temps d’envol et les spectres des ions produits utilisant une pente d’énergie de collision inverse dans un spectromètre de masse à triple quadripôle ont été explorés comme des méthodes de confirmation possibles.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Une nouvelle méthode d'extraction en phase solide (SPE) couplée à une technique d'analyse ultrarapide a été développée pour la détermination simultanée de neuf contaminants émergents (l'atrazine, le déséthylatrazine, le 17(béta)-estradiol, l'éthynylestradiol, la noréthindrone, la caféine, la carbamazépine, le diclofénac et le sulfaméthoxazole) provenant de différentes classes thérapeutiques et présents dans les eaux usées. La pré-concentration et la purification des échantillons a été réalisée avec une cartouche SPE en mode mixte (Strata ABW) ayant à la fois des propriétés échangeuses de cations et d'anions suivie d'une analyse par une désorption thermique par diode laser/ionisation chimique à pression atmosphérique couplée à la spectrométrie de masse en tandem (LDTD-APCI-MS/MS). La LDTD est une nouvelle méthode d'introduction d'échantillon qui réduit le temps total d'analyse à moins de 15 secondes par rapport à plusieurs minutes avec la chromatographie liquide couplée à la spectrométrie de masse en tandem traditionnelle (LC-MS/MS). Plusieurs paramètres SPE ont été évalués dans le but d'optimiser l'efficacité de récupération lors de l'extraction des analytes provenant des eaux usées, tels que la nature de la phase stationnaire, le débit de chargement, le pH d'extraction, le volume et la composition de la solution de lavage et le volume de l'échantillon initial. Cette nouvelle méthode a été appliquée avec succès à de vrais échantillons d'eaux usées provenant d'un réservoir de décantation primaire. Le recouvrement des composés ciblés provenant des eaux usées a été de 78 à 106%, la limite de détection a été de 30 à 122 ng L-1, alors que la limite de quantification a été de 88 à 370 ng L-1. Les courbes d'étalonnage dans les matrices d'eaux usées ont montré une bonne linéarité (R2 > 0,991) pour les analytes cibles ainsi qu’une précision avec un coefficient de variance inférieure à 15%.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Le méthotrexate (MTX), un agent anti-cancéreux fréquemment utilisé en chimiothérapie, requiert généralement un suivi thérapeutique de la médication (Therapeutic Drug Monitoring, TDM) pour surveiller son niveau sanguin chez le patient afin de maximiser son efficacité tout en limitant ses effets secondaires. Malgré la fenêtre thérapeutique étroite entre l’efficacité et la toxicité, le MTX reste, à ce jour, un des agents anti-cancéreux les plus utilisés au monde. Les techniques analytiques existantes pour le TDM du MTX sont coûteuses, requièrent temps et efforts, sans nécessairement fournir promptement les résultats dans le délai requis. Afin d’accélérer le processus de dosage du MTX en TDM, une stratégie a été proposée basée sur un essai compétitif caractérisé principalement par le couplage plasmonique d’une surface métallique et de nanoparticules d’or. Plus précisément, l’essai quantitatif exploite la réaction de compétition entre le MTX et une nanoparticule d’or fonctionnalisée avec l’acide folique (FA-AuNP) ayant une affinité pour un récepteur moléculaire, la réductase humaine de dihydrofolate (hDHFR), une enzyme associée aux maladies prolifératives. Le MTX libre mixé avec les FA-AuNP, entre en compétition pour les sites de liaison de hDHFR immobilisés sur une surface active en SPR ou libres en solution. Par la suite, les FA-AuNP liées au hDHFR fournissent une amplification du signal qui est inversement proportionnelle à la concentration de MTX. La résonance des plasmons de surface (SPR) est généralement utilisée comme une technique spectroscopique pour l’interrogation des interactions biomoléculaires. Les instruments SPR commerciaux sont généralement retrouvés dans les grands laboratoires d’analyse. Ils sont également encombrants, coûteux et manquent de sélectivité dans les analyses en matrice complexe. De plus, ceux-ci n’ont pas encore démontré de l’adaptabilité en milieu clinique. Par ailleurs, les analyses SPR des petites molécules comme les médicaments n’ont pas été explorés de manière intensive dû au défi posé par le manque de la sensibilité de la technique pour cette classe de molécules. Les développements récents en science des matériaux et chimie de surfaces exploitant l’intégration des nanoparticules d’or pour l’amplification de la réponse SPR et la chimie de surface peptidique ont démontré le potentiel de franchir les limites posées par le manque de sensibilité et l’adsorption non-spécifique pour les analyses directes dans les milieux biologiques. Ces nouveaux concepts de la technologie SPR seront incorporés à un système SPR miniaturisé et compact pour exécuter des analyses rapides, fiables et sensibles pour le suivi du niveau du MTX dans le sérum de patients durant les traitements de chimiothérapie. L’objectif de cette thèse est d’explorer différentes stratégies pour améliorer l’analyse des médicaments dans les milieux complexes par les biocapteurs SPR et de mettre en perspective le potentiel des biocapteurs SPR comme un outil utile pour le TDM dans le laboratoire clinique ou au chevet du patient. Pour atteindre ces objectifs, un essai compétitif colorimétrique basé sur la résonance des plasmons de surface localisée (LSPR) pour le MTX fut établi avec des nanoparticules d’or marquées avec du FA. Ensuite, cet essai compétitif colorimétrique en solution fut adapté à une plateforme SPR. Pour les deux essais développés, la sensibilité, sélectivité, limite de détection, l’optimisation de la gamme dynamique et l’analyse du MTX dans les milieux complexes ont été inspectés. De plus, le prototype de la plateforme SPR miniaturisée fut validé par sa performance équivalente aux systèmes SPR existants ainsi que son utilité pour analyser les échantillons cliniques des patients sous chimiothérapie du MTX. Les concentrations de MTX obtenues par le prototype furent comparées avec des techniques standards, soit un essai immunologique basé sur la polarisation en fluorescence (FPIA) et la chromatographie liquide couplée avec de la spectrométrie de masse en tandem (LC-MS/MS) pour valider l’utilité du prototype comme un outil clinique pour les tests rapides de quantification du MTX. En dernier lieu, le déploiement du prototype à un laboratoire de biochimie dans un hôpital démontre l’énorme potentiel des biocapteurs SPR pour utilisation en milieux clinique.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Thèse réalisée en cotutelle avec Michèle Prévost (Ph.D), Professeure titulaire au département des génies civil, géologique et des mines de l'École Polytechnique de Montréal.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Ce projet de maitrise implique le développement et l’optimisation de deux méthodes utilisant la chromatographie liquide à haute performance couplée à la spectrométrie de masse en tandem (HPLC-MS/MS). L'objectif du premier projet était de séparer le plus rapidement possible, simultanément, 71 médicaments traitant la dysfonction érectile (ED) et 11 ingrédients naturels parfois retrouvés avec ces médicaments dans les échantillons suspectés d’être adultérés ou contrefaits. L'objectif du deuxième projet était de développer une méthode de dépistage permettant l'analyse rapide simultanée de 24 cannabinoïdes synthétiques et naturels pour une grande variété d'échantillons tels que les mélanges à base de plantes, des bâtons d'encens, de sérums et de cannabis. Dans les deux projets, la séparation a été réalisée en moins de 10 min et cela en utilisant une colonne C18 à noyau solide 100 x 2,1 mm avec des particules de 2,6 µm de diamètre couplée à un système MS avec trappe ionique orbitale fonctionnant en électronébulisation positive. En raison du nombre élevé de composés dans les deux méthodes et de l’émergence de nouveaux analogues sur le marché qui pourraient être présents dans les échantillons futurs, une méthode de dépistage LC-MS/MS ciblée/non-ciblée a été développée. Pour les deux projets, les limites de détection étaient sous les ng/mL et la variation de la précision et de l’exactitude étaient inférieures de 10,5%. Le taux de recouvrement à partir des échantillons réels variait entre 92 à 111%. L’innovation des méthodes LC-MS/MS développées au cours des projets est que le spectre de masse obtenu en mode balayage lors de l'acquisition, fournit une masse exacte pour tous les composés détectés et permet l'identification des composés initialement non-ciblés, comme des nouveaux analogues. Cette innovation amène une dimension supplémentaire aux méthodes traditionnellement utilisées, en permettant une analyse à haute résolution sur la masse de composés non-ciblés.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In recent years, we observed a significant increase of food fraud ranging from false label claims to the use of additives and fillers to increase profitability. Recently in 2013, horse and pig DNA were detected in beef products sold from several retailers. Mass spectrometry has become the workhorse in protein research and the detection of marker proteins could serve for both animal species and tissue authentication. Meat species authenticity will be performed using a well defined proteogenomic annotation, carefully chosen surrogate tryptic peptides and analysis using a hybrid quadrupole-Orbitrap mass spectrometer. Selected mammalian meat samples were homogenized, proteins were extracted and digested with trypsin. The samples were analyzed using a high-resolution mass spectrometer. The chromatography was achieved using a 30 minutes linear gradient along with a BioBasic C8 100 × 1 mm column at a flow rate of 75 µL/min. The mass spectrometer was operated in full-scan high resolution and accurate mass. MS/MS spectra were collected for selected proteotypic peptides. Muscular proteins were methodically analyzed in silico in order to generate tryptic peptide mass lists and theoretical MS/MS spectra. Following a comprehensive bottom-up proteomic analysis, we were able to detect and identify a proteotypic myoglobin tryptic peptide [120-134] for each species with observed m/z below 1.3 ppm compared to theoretical values. Moreover, proteotypic peptides from myosin-1, myosin-2 and -hemoglobin were also identified. This targeted method allowed a comprehensive meat speciation down to 1% (w/w) of undesired product.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Les cyanobactéries ont une place très importante dans les écosystèmes aquatiques et un nombre important d’espèces considéré comme nuisible de par leur production de métabolites toxiques. Ces cyanotoxines possèdent des propriétés très variées et ont souvent été associées à des épisodes d’empoisonnement. L’augmentation des épisodes d’efflorescence d’origine cyanobactériennes et le potentiel qu’ils augmentent avec les changements climatiques a renchéri l’intérêt de l’étude des cyanobactéries et de leurs toxines. Considérant la complexité chimique des cyanotoxines, le développement de méthodes de détection simples, sensibles et rapides est toujours considéré comme étant un défi analytique. Considérant ces défis, le développement de nouvelles approches analytiques pour la détection de cyanotoxines dans l’eau et les poissons ayant été contaminés par des efflorescences cyanobactériennes nuisibles a été proposé. Une première approche consiste en l’utilisation d’une extraction sur phase solide en ligne couplée à une chromatographie liquide et à une détection en spectrométrie de masse en tandem (SPE-LC-MS/MS) permettant l’analyse de six analogues de microcystines (MC), de l’anatoxine (ANA-a) et de la cylindrospermopsine (CYN). La méthode permet une analyse simple et rapide et ainsi que la séparation chromatographique d’ANA-a et de son interférence isobare, la phénylalanine. Les limites de détection obtenues se trouvaient entre 0,01 et 0,02 μg L-1 et des concentrations retrouvées dans des eaux de lacs du Québec se trouvaient entre 0,024 et 36 μg L-1. Une deuxième méthode a permis l’analyse du b-N-méthylamino-L-alanine (BMAA), d’ANA-a, de CYN et de la saxitoxine (STX) dans les eaux de lac contaminés. L’analyse de deux isomères de conformation du BMAA a été effectuée afin d’améliorer la sélectivité de la détection. L’utilisation d’une SPE manuelle permet la purification et préconcentration des échantillons et une dérivatisation à base de chlorure de dansyle permet une chromatographie simplifiée. L’analyse effectuée par LC couplée à la spectrométrie de masse à haute résolution (HRMS) et des limites de détections ont été obtenues entre 0,007 et 0,01 µg L-1. Des échantillons réels ont été analysés avec des concentrations entre 0,01 et 0,3 µg L-1 permettant ainsi la confirmation de la présence du BMAA dans les efflorescences de cyanobactéries au Québec. Un deuxième volet du projet consiste en l’utilisation d’une technologie d’introduction d’échantillon permettant des analyses ultra-rapides (< 15 secondes/échantillons) sans étape chromatographique, la désorption thermique à diode laser (LDTD) couplée à l’ionisation chimique à pression atmosphérique (APCI) et à la spectrométrie de masse (MS). Un premier projet consiste en l’analyse des MC totales par l’intermédiaire d’une oxydation de Lemieux permettant un bris de la molécule et obtenant une fraction commune aux multiples congénères existants des MC. Cette fraction, le MMPB, est analysée, après une extraction liquide-liquide, par LDTD-APCI-MS/MS. Une limite de détection de 0,2 µg L-1 a été obtenue et des concentrations entre 1 et 425 µg L-1 ont été trouvées dans des échantillons d’eau de lac contaminés du Québec. De plus, une analyse en parallèle avec des étalons pour divers congénères des MC a permis de suggérer la possible présence de congénères ou d’isomères non détectés. Un deuxième projet consiste en l’analyse directe d’ANA-a par LDTD-APCI-HRMS pour résoudre son interférence isobare, la phénylalanine, grâce à la détection à haute résolution. La LDTD n’offre pas de séparation chromatographique et l’utilisation de la HRMS permet de distinguer les signaux d’ANA-a de ceux de la phénylalanine. Une limite de détection de 0,2 µg L-1 a été obtenue et la méthode a été appliquée sur des échantillons réels d’eau avec un échantillon positif en ANA-a avec une concentration de 0,21 µg L-1. Finalement, à l’aide de la LDTD-APCI-HRMS, l’analyse des MC totales a été adaptée pour la chair de poisson afin de déterminer la fraction libre et liée des MC et comparer les résultats avec des analyses conventionnelles. L’utilisation d’une digestion par hydroxyde de sodium précédant l’oxydation de Lemieux suivi d’une purification par SPE a permis d’obtenir une limite de détection de 2,7 µg kg-1. Des échantillons de poissons contaminés ont été analysés, on a retrouvé des concentrations en MC totales de 2,9 et 13,2 µg kg-1 comparativement aux analyses usuelles qui avaient démontré un seul échantillon positif à 2 µg kg-1, indiquant la possible présence de MC non détectés en utilisant les méthodes conventionnelles.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

L’élevage des porcs représente une source importante de déversement d’antibiotiques dans l’environnement par l’intermédiaire de l’épandage du lisier qui contient une grande quantité de ces molécules sur les champs agricoles. Il a été prouvé que ces molécules biologiquement actives peuvent avoir un impact toxique sur l’écosystème. Par ailleurs, elles sont aussi suspectées d’engendrer des problèmes sanitaires et de contribuer à la résistance bactérienne pouvant mener à des infections difficilement traitables chez les humains. Le contrôle de ces substances dans l’environnement est donc nécessaire. De nombreuses méthodes analytiques sont proposées dans la littérature scientifique pour recenser ces composés dans plusieurs types de matrice. Cependant, peu de ces méthodes permettent l’analyse de ces contaminants dans des matrices issues de l’élevage agricole intensif. Par ailleurs, les méthodes analytiques disponibles sont souvent sujettes à des faux positifs compte tenu de la complexité des matrices étudiées et du matériel utilisé et ne prennent souvent pas en compte les métabolites et produits de dégradation. Enfin, les niveaux d’analyse atteints avec ces méthodes ne sont parfois plus à jour étant donné l’évolution de la chimie analytique et de la spectrométrie de masse. Dans cette optique, de nouvelles méthodes d’analyses ont été développées pour rechercher et quantifier les antibiotiques dans des matrices dérivées de l’élevage intensif des porcs en essayant de proposer des approches alternatives sensibles, sélectives et robustes pour quantifier ces molécules. Une première méthode d’analyse basée sur une technique d’introduction d’échantillon alternative à l’aide d’une interface fonctionnant à l’aide d’une désorption thermique par diode laser munie d’une source à ionisation à pression atmosphérique, couplée à la spectrométrie de masse en tandem a été développée. L’objectif est de proposer une analyse plus rapide tout en atteignant des niveaux de concentration adaptés à la matrice étudiée. Cette technique d’analyse couplée à un traitement d’échantillon efficace a permis l’analyse de plusieurs antibiotiques vétérinaires de différentes classes dans des échantillons de lisier avec des temps d’analyse courts. Les limites de détection atteintes sont comprises entre 2,5 et 8,3 µg kg-1 et sont comparables avec celles pouvant être obtenues avec la chromatographie liquide dans une matrice similaire. En vue d’analyser simultanément une série de tétracyclines, une deuxième méthode d’analyse utilisant la chromatographie liquide couplée à la spectrométrie de masse à haute résolution (HRMS) a été proposée. L’utilisation de la HRMS a été motivée par le fait que cette technique d’analyse est moins sensible aux faux positifs que le triple quadripôle traditionnel. Des limites de détection comprises entre 1,5 et 3,6 µg kg-1 ont été atteintes dans des échantillons de lisier en utilisant un mode d’analyse par fragmentation. L’utilisation de méthodes de quantifications ciblées est une démarche intéressante lorsque la présence de contaminants est suspectée dans un échantillon. Toutefois, les contaminants non intégrés à cette méthode d’analyse ciblée ne peuvent être détectés même à de fortes concentrations. Dans ce contexte, une méthode d’analyse non ciblée a été développée pour la recherche de pharmaceutiques vétérinaires dans des effluents agricoles en utilisant la spectrométrie de masse à haute résolution et une cartouche SPE polymérique polyvalente. Cette méthode a permis l’identification d’antibiotiques et de pharmaceutiques couramment utilisés dans l’élevage porcin. La plupart des méthodes d’analyse disponibles dans la littérature se concentrent sur l’analyse des composés parents, mais pas sur les sous-produits de dégradation. L’approche utilisée dans la deuxième méthode d’analyse a donc été étendue et appliquée à d’autres classes d’antibiotiques pour mesurer les concentrations de plusieurs résidus d’antibiotiques dans les sols et les eaux de drainage d’un champ agricole expérimental. Les sols du champ renfermaient un mélange d’antibiotiques ainsi que leurs produits de dégradation relatifs à des concentrations mesurées jusqu’à 1020 µg kg-1. Une partie de ces composés ont voyagé par l’intermédiaire des eaux de drainage du champ ou des concentrations pouvant atteindre 3200 ng L-1 ont pu être relevées.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

La cellulose et ses dérivés sont utilisés dans un vaste nombre d’applications incluant le domaine pharmaceutique pour la fabrication de médicaments en tant qu’excipient. Différents dérivés cellulosiques tels que le carboxyméthylcellulose (CMC) et l’hydroxyéthylcellulose (HEC) sont disponibles sur le commerce. Le degré de polymérisation et de modification diffèrent énormément d’un fournisseur à l’autre tout dépendamment de l’origine de la cellulose et de leur procédé de dérivation, leur conférant ainsi différentes propriétés physico-chimiques qui leurs sont propres, telles que la viscosité et la solubilité. Notre intérêt est de développer une méthode analytique permettant de distinguer la différence entre deux sources d’un produit CMC ou HEC. L’objectif spécifique de cette étude de maitrise était l’obtention d’un profil cartographique de ces biopolymères complexes et ce, par le développement d’une méthode de digestion enzymatique donnant les oligosaccharides de plus petites tailles et par la séparation de ces oligosaccharides par les méthodes chromatographiques simples. La digestion fut étudiée avec différents paramètres, tel que le milieu de l’hydrolyse, le pH, la température, le temps de digestion et le ratio substrat/enzyme. Une cellulase de Trichoderma reesei ATCC 26921 fut utilisée pour la digestion partielle de nos échantillons de cellulose. Les oligosaccharides ne possédant pas de groupements chromophores ou fluorophores, ils ne peuvent donc être détectés ni par absorbance UV-Vis, ni par fluorescence. Il a donc été question d’élaborer une méthode de marquage des oligosaccharides avec différents agents, tels que l’acide 8-aminopyrène-1,3,6-trisulfonique (APTS), le 3-acétylamino-6-aminoacridine (AA-Ac) et la phénylhydrazine (PHN). Enfin, l’utilisation de l’électrophorèse capillaire et la chromatographie liquide à haute performance a permis la séparation des produits de digestion enzymatique des dérivés de cellulose. Pour chacune de ces méthodes analytiques, plusieurs paramètres de séparation ont été étudiés.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Les phytochélatines (PC) sont des polypeptides ayant la structure générale, (alpha-Glu-Cys)n-Gly, où n = 2 à 11. Leur synthèse est induite par un grand nombre de végétaux en réponse à une élévation de la concentration du milieu en métaux, en particulier le cadmium (ci-après, Cd). Le but de cette étude a été de développer un outil pour évaluer la biodisponibilité du Cd dans les eaux douces. Pour ce faire, une méthode analytique a été réalisée afin de déterminer les phytochélatines induites dans les algues C. reinhardtii. Celle-ci consiste à utiliser la chromatographie liquide couplée à la spectrométrie de masse en tandem (LCHP-SM/SM) "on-line". L’ionisation des molécules est celle faite par électronébulisation (IEN) (traduction de electrospray ionisation). L’objectif principal de ce mémoire est la validation de cette méthode : la détermination des courbes de calibration et des limites de détection et l'identification d'interférences potentielles. L’utilisation de dithiothreitol (DTT) à une concentration de 25 mM a été nécessaire à la conservation de la forme réduite des phytochélatines. En effet, suite à la validation de la méthode d’analyse des phytochélatines il a été démontré qu’elle représente un potentiel d’application. Ceci dans la mesure où l’induction des phytochélatines (PC2, PC3 et PC4) dans les algues C. reinhardtii a été possible à deux concentrations de Cd (1 x 10-7 M et 1 x 10 6 M) et ce, après plusieurs temps d'induction (1, 2, 4, et 6 h). Ainsi, l’étude de la stabilité des phytochélatines a été réalisée et toutes les températures examinées ont démontré une diminution des phytochélatines analysées par HPLC-ESI-MS/MS. Il se pourrait que la cause de la dégradation des phytochélatines soit physique ou chimique plutôt que bactérienne. Toutefois, un approfondissement au niveau de la purification de la solution d’extraction serait nécessaire à la mise au point de la dite méthode analytique afin de quantifier les phytochélatines dans l’algue C. reinhardtii.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Les biomarqueurs plasmatiques constituent des outils essentiels, mais rares, utilisés pour diagnostiquer les maladies, comme les maladies cardiovasculaires (MCV), et stratifier le niveau de risque associé. L’identification de nouveaux biomarqueurs plasmatiques susceptibles d’améliorer le dépistage et le suivi des MCV représente ainsi un enjeu majeur en termes d’économie et de santé publique. Le projet vise à identifier de nouveaux biomarqueurs plasmatiques prédictifs ou diagnostiques des MCV, à déterminer le profil protéomique plasmatique de patients atteints de MCV et à développer des méthodes innovantes d’analyse d’échantillon plasmatique. L’étude a été effectuée sur une large banque de plasma provenant de 1006 individus de souche Canadienne-Française recrutés à différents stades de la MCV et qui ont été suivis sur une période de 5 ans. Des séries de déplétions ont été réalisées afin de dépléter les 14 protéines majoritaires (colonne IgY14TM) de l’échantillon avant son analyse par trois approches effectuées en parallèle: 1) Une chromatographie liquide (LC) en 2 dimensions qui fractionne les protéines selon le point isoélectrique puis selon le degré d’hydrophobicité, via le système PF2D, suivie par une chromatographie liquide couplée avec une spectrométrie de masse en tandem (LC-MS/MS). 2) Une séparation classique sur gel 1D-SDS-PAGE suivie d’une LC-MS/MS; 3) Par une déplétion plus poussée du plasma avec l’utilisation en tandem avec la colonne IgY14TM d’une colonne SupermixTM permettant de dépléter également les protéines de moyenne abondance, suivie d’une séparation sur gel 1D-SDS-PAGE et d’une analyse LC-MS/MS de la portion déplétée (3a) et de la portion liée à la SupermixTM (3b). Les résultats montrent que le système PF2D permet d’identifier plusieurs profils protéiques spécifiques au groupe MCV. Sur un total de 1156 fractions (équivalent à 1172 pics protéiques pour le groupe contrôle et 926 pics pour le groupe MCV) recueillies, 15 fractions (23 pics protéiques) présentaient des différences quantitativement significatives (p<0,05) entre les 2 groupes. De plus, 6 fractions (9 pics) sont uniquement présentes dans un groupe, représentant d’autres signatures protéomiques et biomarqueurs potentiellement intéressants. Les méthodes 2, 3a et 3b ont permis l’identification de 108, 125 et 91 protéines respectivement avec des chevauchements partiels (31% entre la méthode 2 et 3a, 61% entre 2 et 3b et 19% entre 3a et 3b). Les méthodes 2 et 3 ont permis l’identification de 12 protéines qui présentaient des différences quantitatives significatives entre les 2 groupes. L’utilisation de plusieurs approches protéomiques complémentaires nous ont d’ores et déjà permis d’identifier des candidats biomarqueurs des angines instables avec récidive d’infarctus du myocarde (IM).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

La cartographie peptidique est une méthode qui permet entre autre d’identifier les modifications post-traductionnelles des protéines. Elle comprend trois étapes : 1) la protéolyse enzymatique, 2) la séparation par électrophorèse capillaire (CE) ou chromatographie en phase liquide à haute performance (HPLC) des fragments peptidiques et 3) l’identification de ces derniers. Cette dernière étape peut se faire par des méthodes photométriques ou par spectrométrie de masse (MS). Au cours de la dernière décennie, les enzymes protéolytiques immobilisées ont acquis une grande popularité parce qu’elles peuvent être réutilisées et permettent une digestion rapide des protéines due à un rapport élevé d’enzyme/substrat. Pour étudier les nouvelles techniques d’immobilisation qui ont été développées dans le laboratoire du Professeur Waldron, la cartographie peptidique par CE est souvent utilisée pour déterminer le nombre total de peptides détectés et leurs abondances. La CE nous permet d’avoir des séparations très efficaces et lorsque couplée à la fluorescence induite par laser (LIF), elle donne des limites de détection qui sont 1000 fois plus basses que celles obtenues avec l’absorbance UV-Vis. Dans la méthode typique, les peptides venant de l’étape 1) sont marqués avec un fluorophore avant l’analyse par CE-LIF. Bien que la sensibilité de détection LIF puisse approcher 10-12 M pour un fluorophore, la réaction de marquage nécessite un analyte dont la concentration est d’au moins 10-7 M, ce qui représente son principal désavantage. Donc, il n’est pas facile d’étudier les enzymes des peptides dérivés après la protéolyse en utilisant la technique CE-LIF si la concentration du substrat protéique initial est inférieure à 10-7 M. Ceci est attribué à la dilution supplémentaire lors de la protéolyse. Alors, afin d’utiliser le CE-LIF pour évaluer l’efficacité de la digestion par enzyme immobilisée à faible concentration de substrat,nous proposons d’utiliser des substrats protéiques marqués de fluorophores pouvant être purifiés et dilués. Trois méthodes de marquage fluorescent de protéine sont décrites dans ce mémoire pour étudier les enzymes solubles et immobilisées. Les fluorophores étudiés pour le marquage de protéine standard incluent le naphtalène-2,3-dicarboxaldéhyde (NDA), la fluorescéine-5-isothiocyanate (FITC) et l’ester de 6-carboxyfluorescéine N-succinimidyl (FAMSE). Le FAMSE est un excellent réactif puisqu’il se conjugue rapidement avec les amines primaires des peptides. Aussi, le substrat marqué est stable dans le temps. Les protéines étudiées étaient l’-lactalbumine (LACT), l’anhydrase carbonique (CA) et l’insuline chaîne B (INB). Les protéines sont digérées à l’aide de la trypsine (T), la chymotrypsine (CT) ou la pepsine (PEP) dans leurs formes solubles ou insolubles. La forme soluble est plus active que celle immobilisée. Cela nous a permis de vérifier que les protéines marquées sont encore reconnues par chaque enzyme. Nous avons comparé les digestions des protéines par différentes enzymes telles la chymotrypsine libre (i.e., soluble), la chymotrypsine immobilisée (i.e., insoluble) par réticulation avec le glutaraldéhyde (GACT) et la chymotrypsine immobilisée sur billes d’agarose en gel (GELCT). Cette dernière était disponible sur le marché. Selon la chymotrypsine utilisée, nos études ont démontré que les cartes peptidiques avaient des différences significatives selon le nombre de pics et leurs intensités correspondantes. De plus, ces études nous ont permis de constater que les digestions effectuées avec l’enzyme immobilisée avaient une bonne reproductibilité. Plusieurs paramètres quantitatifs ont été étudiés afin d’évaluer l’efficacité des méthodes développées. La limite de détection par CE-LIF obtenue était de 3,010-10 M (S/N = 2,7) pour la CA-FAM digérée par GACT et de 2,010-10 M (S/N = 4,3) pour la CA-FAM digérée par la chymotrypsine libre. Nos études ont aussi démontrées que la courbe d’étalonnage était linéaire dans la région de travail (1,0×10-9-1,0×10-6 M) avec un coefficient de corrélation (R2) de 0,9991.