22 resultados para Risks Assessment Methods


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Triple quadrupole mass spectrometers coupled with high performance liquid chromatography are workhorses in quantitative bioanalyses. It provides substantial benefits including reproducibility, sensitivity and selectivity for trace analysis. Selected Reaction Monitoring allows targeted assay development but data sets generated contain very limited information. Data mining and analysis of non-targeted high-resolution mass spectrometry profiles of biological samples offer the opportunity to perform more exhaustive assessments, including quantitative and qualitative analysis. The objectives of this study was to test method precision and accuracy, statistically compare bupivacaine drug concentration in real study samples and verify if high resolution and accurate mass data collected in scan mode can actually permit retrospective data analysis, more specifically, extract metabolite related information. The precision and accuracy data presented using both instruments provided equivalent results. Overall, the accuracy was ranging from 106.2 to 113.2% and the precision observed was from 1.0 to 3.7%. Statistical comparisons using a linear regression between both methods reveal a coefficient of determination (R2) of 0.9996 and a slope of 1.02 demonstrating a very strong correlation between both methods. Individual sample comparison showed differences from -4.5% to 1.6% well within the accepted analytical error. Moreover, post acquisition extracted ion chromatograms at m/z 233.1648 ± 5 ppm (M-56) and m/z 305.2224 ± 5 ppm (M+16) revealed the presence of desbutyl-bupivacaine and three distinct hydroxylated bupivacaine metabolites. Post acquisition analysis allowed us to produce semiquantitative evaluations of the concentration-time profiles for bupicavaine metabolites.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Injectable drug nanocarriers have greatly benefited in their clinical development from the addition of a superficial hydrophilic corona to improve their cargo pharmacokinetics. The most studied and used polymer for this purpose is poly(ethylene glycol), PEG. However, in spite of its wide use for over two decades now, there is no general consensus on the optimum PEG chain coverage-density and size required to escape from the mononuclear phagocyte system and to extend the circulation time. Moreover, cellular uptake and active targeting may have conflicting requirements in terms of surface properties of the nanocarriers which complicates even more the optimization process. These persistent issues can be largely attributed to the lack of straightforward characterization techniques to assess the coverage-density, the conformation or the thickness of a PEG layer grafted or adsorbed on a particulate drug carrier and is certainly one of the main reasons why so few clinical applications involving PEG coated particle-based drug delivery systems are under clinical trial so far. The objective of this review is to provide the reader with a brief description of the most relevant techniques used to assess qualitatively or quantitatively PEG chain coverage-density, conformation and layer thickness on polymeric nanoparticles. Emphasis has been made on polymeric particle (solid core) either made of copolymers containing PEG chains or modified after particle formation. Advantages and limitations of each technique are presented as well as methods to calculate PEG coverage-density and to investigate PEG chains conformation on the NP surface.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dans le cadre de l’évaluation pré-chirurgicale de patients épileptiques, il est impératif de déterminer la spécialisation hémisphérique du langage, ainsi que de localiser les aires du langage au sein de cet hémisphère. De nouvelles méthodes d’évaluation non- invasives doivent être mises au point afin de diminuer les risques associés aux méthodes plus invasives telles que le test à l’amobarbital intracarotidien (TAI). L’objectif principal de cette thèse est donc de développer un protocole d’évaluation pré-chirurgicale alternatif et non-invasif à l’aide de la magnétoencéphalographie (MEG) pour la latéralisation et la localisation du langage, incluant la mémoire verbale qui serait éventuellement accessible à une population pédiatrique francophone épileptique. L’article 1 présente une recension de la littérature résumant les différentes études en MEG ayant pour objectif l’évaluation pré-chirurgicale du langage. Trente-sept articles en MEG ont été analysés pour déterminer quelles tâches permettaient d’obtenir les meilleurs résultats de latéralisation intrahémisphérique et de localisation du langage pour l’évaluation du langage réceptif et expressif chez des sujets neurologiquement sains et épileptiques. Parmi les tests retenus, l’épreuve de reconnaissance de mots permet d’évaluer le langage réceptif et la mémoire verbale, tandis que des épreuves de fluence verbale telles que la génération de verbes permettent d’évaluer le langage expressif de façon à obtenir de très bons résultats. L’article 2 a permis de valider un protocole auprès de sujets neurologiquement sains à l’aide des épreuves identifiées dans l’article 1. Le protocole utilisé comprend une tâche de langage réceptif et de mémoire verbale (une épreuve de reconnaissance de mots) et une tâche de langage expressif (une épreuve de fluence verbale). Suite à la validation du protocole à l’aide d’analyses par composantes principales, les épreuves ont été administrées à un groupe de patients épileptiques. Les index de latéralité et les analyses de sources i révèlent que la MEG permet de localiser et de latéraliser les fonctions langagières et pourrait donc être utilisée comme méthode d'évaluation du langage lors de l'évaluation pré- chirurgicale auprès de patients épileptiques. Toutefois, alors que l’épreuve de mémoire verbale a permis d’obtenir les meilleurs résultats auprès de l’ensemble des participants, l’épreuve de fluence verbale n’a fourni des informations supplémentaires que chez un seul patient et chez aucun participant neurologiquement sain. En résumé, les deux articles de cette thèse démontrent le potentiel clinique de la MEG pour l’évaluation pré-chirurgicale de patients souffrant d’une épilepsie réfractaire.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose. Clinicians commonly assess posture in persons with musculoskeletal disorders and tend to do so subjectively. Evidence-based practice requires the use of valid, reliable and sensitive tools to monitor treatment effectiveness. The purpose of this article was to determine which methods were used to assess posture quantitatively in a clinical setting and to identify psychometric properties of posture indices measured from these methods or tools. Methods. We conducted a comprehensive literature review. Pertinent databases were used to search for articles on quantitative clinical assessment of posture. Searching keywords were related to posture and assessment, scoliosis, back pain, reliability, validity and different body segments. Results. We identified 65 articles with angle and distance posture indices that corresponded to our search criteria. Several studies showed good intra- and inter-rater reliability for measurements taken directly on the persons (e.g., goniometer, inclinometer, flexible curve and tape measurement) or from photographs, but the validity of these measurements was not always demonstrated. Conclusion. Taking measurements of all body angles directly on the person is a lengthy process and may affect the reliability of the measurements. Measurement of body angles from photographs may be the most accurate and rapid way to assess global posture quantitatively in a clinical setting.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Scoliosis is a 3D deformity of the spine and rib cage. Extensive validation of 3D reconstruction methods of the spine from biplanar radiography has already been published. In this article, we propose a novel method to reconstruct the rib cage, using the same biplanar views as for the 3D reconstruction of the spine, to allow clinical assessment of whole trunk deformities. This technique uses a semi-automatic segmentation of the ribs in the postero-anterior X-ray view and an interactive segmentation of partial rib edges in the lateral view. The rib midlines are automatically extracted in 2D and reconstructed in 3D using the epipolar geometry. For the ribs not visible in the lateral view, the method predicts their 3D shape. The accuracy of the proposed method has been assessed using data obtained from a synthetic bone model as a gold standard and has also been evaluated using data of real patients with scoliotic deformities. Results show that the reconstructed ribs enable a reliable evaluation of the rib axial rotation, which will allow a 3D clinical assessment of the spine and rib cage deformities.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Study Design. Reliability study. Objectives. To assess between-acquisition reliability of new multilevel trunk cross sections measurements, in order to define what is a real change when comparing 2 trunk surface acquisitions of a same patient, before and after surgery or throughout the clinical monitoring. Summary of Background Data. Several cross-sectional surface measurements have been proposed in the literature for noninvasive assessment of trunk deformity in patients with adolescent idiopathic scoliosis (AIS). However, only the maximum values along the trunk are evaluated and used for monitoring progression and assessing treatment outcome. Methods. Back surface rotation (BSR), trunk rotation (TR), and coronal and sagittal trunk deviation are computed on 300 cross sections of the trunk. Each set of 300 measures is represented as a single functional data, using a set of basis functions. To evaluate between-acquisition variability at all trunk levels, a test-retest reliability study is conducted on 35 patients with AIS. A functional correlation analysis is also carried out to evaluate any redundancy between the measurements. Results. Each set of 300 measures was successfully described using only 10 basis functions. The test-retest reliability of the functional measurements is good to very good all over the trunk, except above the shoulders level. The typical errors of measurement are between 1.20° and 2.2° for the rotational measures and between 2 and 6 mm for deviation measures. There is a very strong correlation between BSR and TR all over the trunk, a moderate correlation between coronal trunk deviation and both BSR and TR, and no correlation between sagittal trunk deviation and any other measurement. Conclusion. This novel representation of trunk surface measurements allows for a global assessment of trunk surface deformity. Multilevel trunk measurements provide a broader perspective of the trunk deformity and allow a reliable multilevel monitoring during clinical follow-up of patients with AIS and a reliable assessment of the esthetic outcome after surgery.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Improving the appearance of the trunk is an important goal of scoliosis surgical treatment, mainly in patients' eyes. Unfortunately, existing methods for assessing postoperative trunk appearance are rather subjective as they rely on a qualitative evaluation of the trunk shape. In this paper, an objective method is proposed to quantify the changes in trunk shape after surgery. Using a non-invasive optical system, the whole trunk surface is acquired and reconstructed in 3D. Trunk shape is described by two functional measurements spanning the trunk length: the lateral deviation and the axial rotation. To measure the pre and postoperative differences, a correction rate is computed for both measurements. On a cohort of 36 scoliosis patients with the same spinal curve type who underwent the same surgical approach, surgery achieved a very good correction of the lateral trunk deviation (median correction of 76%) and a poor to moderate correction of the back axial rotation (median correction of 19%). These results demonstrate that after surgery, patients are still confronted with residual trunk deformity, mainly a persisting hump on the back. That can be explained by the fact that current scoliosis assessment and treatment planning are based solely on radiographic measures of the spinal deformity and do not take trunk deformity into consideration. It is believed that with our novel quantitative trunk shape descriptor, clinicians and surgeons can now objectively assess trunk deformity and postoperative shape and propose new treatment strategies that could better address patients' concern about their appearance. © (2013) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.