6 resultados para styrene butadiene rubber (SBR)

em Brock University, Canada


Relevância:

10.00% 10.00%

Publicador:

Resumo:

This project is focussed on the thermsLl decomposition of t-butyl hydroperoxide and sec-butyl hydroperoxide at 120°C to 160°C in three alcohol solvents. These are methanol, ethajiol and isopropyl alcohol. The aim of the project was to examine the process of induced decomposition. Thermal decomposition of t-hutyl hydroperoxide and sec-butyl hydroperoxide indicate that these reactions have first-order kinetics with activation energies on the order of 20 to 28 K cal/mole, Styrene was used as a free radical trap to inhibit the induced decomposition. The results permitted calculation of how much induced decomposition occurred in its absence. The experimental resvilts indicate that the induced decomposition is important for t-butyl hydroperoxide in alcohol solvents, as shown by both the reaction rate suid product studies. But sec-butyl hydroperoxide results show that the concerted mechanism for the interaction of two sec-butylperoxy radicals occurs in addition to the induced decomposition. Di-sodium E.D,T.A. was added to reduce possible effects of trace transition metal ion .impurities. The result of this experiment were not as expected. The rate of hydroperoxide decomposition was about the same but was zero-order in hydroperoxide concentration.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Kinetics and product studies of the decompositions of allyl-t-butyl peroxide and 3-hydroperoxy- l-propene (allyl hydroperoxide ) in tolune were investigated. Decompositions of allyl-t-butyl peroxide in toluene at 130-1600 followed first order kinetics with an activation energy of 32.8 K.cals/mol and a log A factor of 13.65. The rates of decomposition were lowered in presence of the radical trap~methyl styrene. By the radical trap method, the induced decomposition at 1300 is shown to be 12.5%. From the yield of 4-phenyl-l,2- epoxy butane the major path of induced decomposition is shown to be via an addition mechanism. On the other hand, di-t-butYl peroxyoxalate induced decomposition of this peroxide at 600 proceeded by an abstraction mechanism. Induced decomposition of peroxides and hydroperoxides containing the allyl system is proposed to occur mainly through an addition mechanism at these higher temperatures. Allyl hydroperoxide in toluene at 165-1850 decomposes following 3/2 order kinetics with an Ea of 30.2 K.cals per mole and log A of 10.6. Enormous production of radicals through chain branching may explain these relatively low values of E and log A. The complexity of the reaction is indicated a by the formation of various products of the decomposition. A study of the radical attack of the hydro peroxide at lower temperatures is suggested as a further work to throw more light on the nature of decomposition of this hydroperoxide.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This research was directed towards the investigation of the Smiles rearrangement in hydrazidic systems and the synthesis of related heterocyclic compounds. The work can be conveniently divided into two main sections. Section 1 of the thesis relates to the synthesis and examination of the O+N migration of phenoxy- derivatives of hydrazidic halides. In general, hydrazidic halides were found to react with 2-nitrophenol and 4-nitrophenol to give corresponding a-nitrophenoxy- compounds. These a-nitrophenoxy- compounds were found to rearrange in warm base to give the corresponding N-benzoyl compounds via a proposed five-membered transition state. Experiments conducted in styrene revealed no radical contribution to the rearrangement. Cross-over product analysis indicated the rearrangement as intramolecular and consistent with the Smiles rearrangement. The preparation of N-a-chlorobenzylidene-N'-2-nitrophenyl- -N'-(2,4-dibromophenyl)hydrazine from N-benzoyl-N'-2-nitrophenyl- N'-(2,4-dibromophenyl)hydrazine was accomplished using phosphorus oxychloride. Examination of this hydrazidic chloride indicated a marked decrease .in reactivity as compared to the N-a-chlorobenzylidene-N'-phenylhydrazine case. Section 2 concerns itself with the preparation of heterocyclic compounds using an analogy of the five-membered transition state present in the Smiles rearrangement of a substituted benzylidene derivatives A new preparation of 2,4-phenyl1,3,4- oxadiazol-S-one using N-benzoyl-N'-phenylhydrazine and ethyl thiochloroformate is reported. Two new preparations of N-a-thiobenzoyl-N'-(2,4-dibromophenylhydrazine are reported using sodium hydrosulfide in conjunction with N-a-bromobenzylidene-N'-(2,4-dibromophenyl)hydrazine in the first, and phosphorus pentasulfide with N-benzoylN'-( 2,4-dibromophenyl)hydrazine in the second. The latter is preferred due to the formation of a sulfide co-product in the former. Two preparations of 2-phenyl-4-(2,4-dibromophenyl)-1,3,4- thiadiazol-S-one are reported using N-thiobenzoyl-N'-(2,4-dibromophenyl) hydrazine and ethyl chloroformate and ethyl thiochloroformate Two rapid and easy preparations of 2-phenyl-4-(2,4-dibromophenyl)- 1,3,4-triazol-S-one are reported using ethyl chloroformate and ethyl thiochloroformate. Sodium cyanate in conjunction with a-aminobenzylidene-N'-(2,4-dibromophenyl)hydrazine also provided 2-phenyl-4-(2,4-dibromophenyl)-1,3,4-triazol-S-one Section 2 concludes with an examination of two possible mechanistic routes to the prepared heterocycles.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A simple, low-cost concentric capillary nebulizer (CCN) was developed and evaluated for ICP spectrometry. The CCN could be operated at sample uptake rates of 0.050-1.00 ml min'^ and under oscillating and non-oscillating conditions. Aerosol characteristics for the CCN were studied using a laser Fraunhofter diffraction analyzer. Solvent transport efficiencies and transport rates, detection limits, and short- and long-term stabilities were evaluated for the CCN with a modified cyclonic spray chamber at different sample uptake rates. The Mg II (280.2nm)/l\/lg 1(285.2nm) ratio was used for matrix effect studies. Results were compared to those with conventional nebulizers, a cross-flow nebulizer with a Scott-type spray chamber, a GemCone nebulizer with a cyclonic spray chamber, and a Meinhard TR-30-K3 concentric nebulizer with a cyclonic spray chamber. Transport efficiencies of up to 57% were obtained for the CCN. For the elements tested, short- and long-term precisions and detection limits obtained with the CCN at 0.050-0.500 ml min'^ are similar to, or better than, those obtained on the same instrument using the conventional nebulizers (at 1.0 ml min'^). The depressive and enhancement effects of easily ionizable element Na, sulfuric acid, and dodecylamine surfactant on analyte signals with the CCN are similar to, or better than, those obtained with the conventional nebulizers. However, capillary clog was observed when the sample solution with high dissolved solids was nebulized for more than 40 min. The effects of data acquisition and data processing on detection limits were studied using inductively coupled plasma-atomic emission spectrometry. The study examined the effects of different detection limit approaches, the effects of data integration modes, the effects of regression modes, the effects of the standard concentration range and the number of standards, the effects of sample uptake rate, and the effect of Integration time. All the experiments followed the same protocols. Three detection limit approaches were examined, lUPAC method, the residual standard deviation (RSD), and the signal-to-background ratio and relative standard deviation of the background (SBR-RSDB). The study demonstrated that the different approaches, the integration modes, the regression methods, and the sample uptake rates can have an effect on detection limits. The study also showed that the different approaches give different detection limits and some methods (for example, RSD) are susceptible to the quality of calibration curves. Multicomponents spectral fitting (MSF) gave the best results among these three integration modes, peak height, peak area, and MSF. Weighted least squares method showed the ability to obtain better quality calibration curves. Although an effect of the number of standards on detection limits was not observed, multiple standards are recommended because they provide more reliable calibration curves. An increase of sample uptake rate and integration time could improve detection limits. However, an improvement with increased integration time on detection limits was not observed because the auto integration mode was used.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Interlake Tissue Mills storage location was at the intersection of Glendale and Merritt Street in Merritton. In the 1850s, the Beaver Cotton Mills (later Merritton Cotton Mills) was built. It was a frame building that burned down in 1881. A sandstone structure replaced the previous building. In 1906, the cotton mill closed and in 1912, the Independent Rubber Company took over the building. The mill was doubled in size. The rubber company remained there for ten years and then the building remained vacant until 1935. Interlake Tissue Mills acquired the building for storage purposes. A fire razed the larger of the plant’s buildings on Memorial Day weekend in 1961. After the fire, Domtar used the smaller building for storage for a short time. This is currently the site of the Keg Restaurant.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

CASCO (Canada Starch Company) began operations in 1982 and was officially opened in May of 1983. Premier William Davis was in attendance. CASCO is a company whose roots can be traced back to 1858 when it was founded by W.T. Benson in Cardinal, Ontario. The company grew as corn uses were developed. Corn derived products now include: corn oil, liquid sweetener and feed for dairy and cattle. Starch is used as a finish for fine papers, a component in dry cell batteries, pharmaceuticals, wallpaper, film, tires, surgical dressings, plastics and plywood. Corn syrup is used in beverages, canned fruit, frozen seafood, licorice, ice cream and baking products. Corn solubles are used in animal feed, rubber substitutes, soap, paint and varnish. There are more than 250 industrial and food uses for corn