9 resultados para pesticide contaminants
em Brock University, Canada
Resumo:
This investigation of geochemistry and mineralogy of heavy metals in fine grained (<63^m) sediment of the Welland River was imdertaken to: 1) describe metal dispersion patterns relative to a source, identify minerals forming and existing at the outfall region and relate sediment particle size to chemistry; 2) to delineate sample handling, preparation and evaluate, modify and develop analytical methods for heavy metal analysis of complex environmental samples. Ajoint project between Brock University and Geoscience Laboratories was initiated to test a contaminated site of the Welland River at the base of Atlas Speciality Steels Co. Methods were developed and utilized for particle size separation and two acid extraction techniques: 1) Partial extraction; 2) Total extraction. The mineralogical assessment identified calcite, dolomite, quartz and clays. These minerals are typical of the carbonate-shale rock basement of the Niagara Peninsula. Minerals such as, mullite and ferrocolumbite were found at the outfall region. These are not typical of the local geology and are generally associated with industrial pollutants. Partial and total extraction techniques were used to characterize the sediments based on chemical distribution, elemental behaviour and analytical differences. The majority of elements were lower in concentration in the partial extraction technique; suggesting these elements are bound in an acid extractable phase (exchangeable, organic and carbonate phases). The total extraction technique yielded higher elemental concentrations taking difficult oxides and silicates into solution. Geochemical analyses of grain size separates revealed that heavy metal (Co, Ni, V, Mn, Fe, Ba) concentrations did not increase with decreasing grain size. This is a function of the anthropogenic mill scale input into the river. The background elements (Sc, Y, Sr, Mg, Al and Ti) showed an increase in concentration to the finest grain size suggesting that it is directly related to the local mineralogy and geology. Dispersion patterns ofmetals fall into two distinct categories: 1) the heavy metals (Co, Cu, Ni, Zn, V and Cr), and 2) the background elements (Be, Sc, Y, Sr, Al and Ti). The heavy metals show a marked increase in the outfall region, while the background elements show a significant decrease at the outfall. This pattern is attributed to a "dilution effect" ofthe natural sediments by the anthropogenic mill scale sediments. Multivariant statistical analysis and correlation coefficient matrix results clearly support these results and conclusions. These results indicate the outfall region ofthe Welland River is highly contaminated with to heavy metals from the industrialized area of Welland. A short distance downstream, the metal concentrations return to baseline geochemical levels. It appears, contaminants rapidly come out of suspension and are deposited in close proximity to the source. Therefore, it is likely that dredging the sediment from the river may cause resuspension of contaminated sediments, but may not distribute the sediment as far as initially anticipated.
Resumo:
The carbamate pesticide, carbaryl, was quantitatively studied using fast atom bombardment mass spectrometry (FAB-MS). Mass spectra were obtained in the positive ion-mode using both 2-nitrophenyloctyl ether (NPOE) and 3-nitrobenzyl alcohol (NBA) as matrix liquids. The sample was applied by three different techniques; simple mixing, solvent mixing and surface precipitation. Smaller volumes of matrix liquid were found to produce more favourable ion currents. Detection limits were largely independent of the matrix or application technique used. The relationship between ion current and the mass of analyte was found to be intricately related to the choice of matrix liquid.
Resumo:
Factors affecting the detennination of PAHs by capillary GC/MS were studied. The effect of the initial column temperature and the injection solvent on the peak areas and heights of sixteen PAHs, considered as priority pollutants, USillg crosslinked methyl silicone (DB!) and 5% diphenyl, 94% dimethyl, 1% vinyl polysiloxane (DBS) columns was examined. The possibility of using high boiling point alcohols especially butanol, pentanol, cyclopentanol, and hexanol as injection solvents was investigated. Studies were carried out to optimize the initial column temperature for each of the alcohols. It was found that the optimum initial column temperature is dependent on the solvent employed. The peak areas and heights of the PAHs are enhanced when the initial column temperature is 10-20 c above the boiling point of the solvent using DB5 column, and the same or 10 C above the boiling point of the solvent using DB1 column. Comparing the peak signals of the PAHs using the alcohols, p-xylene, n-octane, and nonane as injection solvents, hexanol gave the greatest peak areas and heights of the PAHs particularly the late-eluted peaks. The detection limits were at low pg levels, ranging from 6.0 pg for fluorene t9 83.6 pg for benzo(a)pyrene. The effect of the initial column temperature on the peak shape and the separation efficiency of the PARs was also studied using DB1 and DB5 columns. Fronting or splitting of the peaks was obseIVed at very low initial column temperature. When high initial column temperature was used, tailing of the peaks appeared. Great difference between DB! and.DB5 columns in the range of the initial column temperature in which symmetrical.peaks of PAHs can be obtained is observed. Wider ranges were shown using DB5 column. Resolution of the closely-eluted PAHs was also affected by the initial column temperature depending on the stationary phase employed. In the case of DB5, only the earlyeluted PAHs were affected; whereas, with DB1, all PAHs were affected. An analytical procedure utilizing solid phase extraction with bonded phase silica (C8) cartridges combined with GC/MS was developed to analyze PAHs in water as an alternative method to those based on the extraction with organic solvent. This simple procedure involved passing a 50 ml of spiked water sample through C8 bonded phase silica cartridges at 10 ml/min, dried by passing a gentle flow of nitrogen at 20 ml/min for 30 sec, and eluting the trapped PAHs with 500 Jll of p-xylene at 0.3 ml/min. The recoveries of PAHs were greater than 80%, with less than 10% relative standard deviations of nine determinations. No major contaminants were present that could interfere with the recognition of PAHs. It was also found that these bonded phase silica cartridges can be re-used for the extraction of PAHs from water.
Resumo:
Sediment samples were taken from seven locations in the
WeIland River in December 1986 and April 1987. The DMSO extracts
of these sediment samples showed a significant (p
Resumo:
Thesis (Ph.D.)--Brock University, 2010.
Resumo:
A room temperature ferromagnetic hysteresis is observed in single crystal strontium titanate substrates as purchased from several manufacturers. It was found that polishing all sides of the substrates removed this observed hysteresis, suggesting that the origin of the ferromagnetic behavior resides on the surface of the substrates. X-ray diffraction and energy dispersive x-ray spectra were measured however they were unable to detect any impurity phases. In similar semiconducting oxides it was previously suggested that ferromagnetism could originate in oxygen vacancies or from disorder within the single crystal. To this end substrates were annealed in both air and vacuum in a range of temperatures (600°C to 1100°G) to both create bulk oxygen vacancies and to heal surface damage. Annealing in vacuum was found to create a measureable number of oxygen vacancies however their creation could not be correlated to the ferromagnetic signal of the substrate. Annealing in air was found to effect the remnant moment of the substrate as well as the width of the x-ray diffraction peaks on the unpolished face, weakly suggesting a relation between surface based disorder and ferromagnetism. Argon ion bombardment was employed to create a layer of surface disorder in the polished crystal, however it was not found to induce ferromagnetism. It was found that acid etching was sufficient to remove the ferromagnetism from as purchased samples and similarly simulated handling with stainless steel tweezers was sufficient to re-create the ferromagnetism. It is suggested that the origin of this ferromagnetism in SrTi03 is surface contaminants (mainly iron).
Resumo:
Rural communities are currently undergoing rapid restructuring as globalization impacts the future viability of many small towns. Agricultural regions throughout Canada, in particular, Niagara-on-the-Lake, are forced to adapt to changes within the industry. In addition to these challenges, sprawling residential developments from nearby urban centres are changing the dynamic of this town, resulting in conflicts between the residential and agricultural land uses. This thesis explores these conflicts from the perspective of the residents and the farmers. It was found that the initial sources of conflict related to noise-generating farm activities are no longer a concern, while the use of pesticide have become a source of contention among the residents. The farmers, alternately, were found to be proactive and strived to limit the potential for conflict with adjacent residents. Lastly, it was determined that planning legislation aggravates land use conflicts within Niagara-on-the-Lake and need to better address these land use conflicts.
Resumo:
On average approximately 13% of the water that is withdrawn by Canadian municipal water suppliers is lost before it reaches final users. This is an important topic for several reasons: water losses cost money, losses force water agencies to draw more water from lakes and streams thereby putting more stress on aquatic ecosystems, leaks reduce system reliability, leaks may contribute to future pipe failures, and leaks may allow contaminants to enter water systems thereby reducing water quality and threatening the health of water users. Some benefits of leak detection fall outside water agencies’ accounting purview (e.g. reduced health risks to households connected to public water supply systems) and, as a result, may not be considered adequately in water agency decision-making. Because of the regulatory environment in which Canadian water agencies operate, some of these benefits-especially those external to the agency or those that may accrue to the agency in future time periods- may not be fully counted when agencies decide on leak detection efforts. Our analysis suggests potential reforms to promote increased efforts for leak detection: adoption of a Canada-wide goal of universal water metering; development of full-cost accounting and, pricing for water supplies; and co-operation amongst the provinces to promulgate standards for leak detection efforts and provide incentives to promote improved efficiency and rational investment decision-making.
Resumo:
Part I: Ultra-trace determination of vanadium in lake sediments: a performance comparison using O2, N20, and NH3 as reaction gases in ICP-DRC-MS Thermal ion-molecule reactions, targeting removal of specific spectroscopic interference problems, have become a powerful tool for method development in quadrupole based inductively coupled plasma mass spectrometry (ICP-MS) applications. A study was conducted to develop an accurate method for the determination of vanadium in lake sediment samples by ICP-MS, coupled with a dynamic reaction cell (DRC), using two differenvchemical resolution strategies: a) direct removal of interfering C10+ and b) vanadium oxidation to VO+. The performance of three reaction gases that are suitable for handling vanadium interference in the dynamic reaction cell was systematically studied and evaluated: ammonia for C10+ removal and oxygen and nitrous oxide for oxidation. Although it was able to produce comparable results for vanadium to those using oxygen and nitrous oxide, NH3 did not completely eliminate a matrix effect, caused by the presence of chloride, and required large scale dilutions (and a concomitant increase in variance) when the sample and/or the digestion medium contained large amounts of chloride. Among the three candidate reaction gases at their optimized Eonditions, creation of VO+ with oxygen gas delivered the best analyte sensitivity and the lowest detection limit (2.7 ng L-1). Vanadium results obtained from fourteen lake sediment samples and a certified reference material (CRM031-040-1), using two different analytelinterference separation strategies, suggested that the vanadium mono-oxidation offers advantageous performance over the conventional method using NH3 for ultra-trace vanadium determination by ICP-DRC-MS and can be readily employed in relevant environmental chemistry applications that deal with ultra-trace contaminants.Part II: Validation of a modified oxidation approach for the quantification of total arsenic and selenium in complex environmental matrices Spectroscopic interference problems of arsenic and selenium in ICP-MS practices were investigated in detail. Preliminary literature review suggested that oxygen could serve as an effective candidate reaction gas for analysis of the two elements in dynamic reaction cell coupled ICP-MS. An accurate method was developed for the determination of As and Se in complex environmental samples, based on a series of modifications on an oxidation approach for As and Se previously reported. Rhodium was used as internal standard in this study to help minimize non-spectral interferences such as instrumental drift. Using an oxygen gas flow slightly higher than 0.5 mL min-I, arsenic is converted to 75 AS160+ ion in an efficient manner whereas a potentially interfering ion, 91Zr+, is completely removed. Instead of using the most abundant Se isotope, 80Se, selenium was determined by a second most abundant isotope, 78Se, in the form of 78Se160. Upon careful selection of oxygen gas flow rate and optimization ofRPq value, previous isobaric threats caused by Zr and Mo were reduced to background levels whereas another potential atomic isobar, 96Ru+, became completely harmless to the new selenium analyte. The new method underwent a strict validation procedure where the recovery of a suitable certified reference material was examined and the obtained sample data were compared with those produced by a credible external laboratory who analyzed the same set of samples using a standardized HG-ICP-AES method. The validation results were satisfactory. The resultant limits of detection for arsenic and selenium were 5 ng L-1 and 60 ng L-1, respectively.