3 resultados para peak-to-plateau ratio
em Brock University, Canada
Resumo:
A simple, low-cost concentric capillary nebulizer (CCN) was developed and evaluated for ICP spectrometry. The CCN could be operated at sample uptake rates of 0.050-1.00 ml min'^ and under oscillating and non-oscillating conditions. Aerosol characteristics for the CCN were studied using a laser Fraunhofter diffraction analyzer. Solvent transport efficiencies and transport rates, detection limits, and short- and long-term stabilities were evaluated for the CCN with a modified cyclonic spray chamber at different sample uptake rates. The Mg II (280.2nm)/l\/lg 1(285.2nm) ratio was used for matrix effect studies. Results were compared to those with conventional nebulizers, a cross-flow nebulizer with a Scott-type spray chamber, a GemCone nebulizer with a cyclonic spray chamber, and a Meinhard TR-30-K3 concentric nebulizer with a cyclonic spray chamber. Transport efficiencies of up to 57% were obtained for the CCN. For the elements tested, short- and long-term precisions and detection limits obtained with the CCN at 0.050-0.500 ml min'^ are similar to, or better than, those obtained on the same instrument using the conventional nebulizers (at 1.0 ml min'^). The depressive and enhancement effects of easily ionizable element Na, sulfuric acid, and dodecylamine surfactant on analyte signals with the CCN are similar to, or better than, those obtained with the conventional nebulizers. However, capillary clog was observed when the sample solution with high dissolved solids was nebulized for more than 40 min. The effects of data acquisition and data processing on detection limits were studied using inductively coupled plasma-atomic emission spectrometry. The study examined the effects of different detection limit approaches, the effects of data integration modes, the effects of regression modes, the effects of the standard concentration range and the number of standards, the effects of sample uptake rate, and the effect of Integration time. All the experiments followed the same protocols. Three detection limit approaches were examined, lUPAC method, the residual standard deviation (RSD), and the signal-to-background ratio and relative standard deviation of the background (SBR-RSDB). The study demonstrated that the different approaches, the integration modes, the regression methods, and the sample uptake rates can have an effect on detection limits. The study also showed that the different approaches give different detection limits and some methods (for example, RSD) are susceptible to the quality of calibration curves. Multicomponents spectral fitting (MSF) gave the best results among these three integration modes, peak height, peak area, and MSF. Weighted least squares method showed the ability to obtain better quality calibration curves. Although an effect of the number of standards on detection limits was not observed, multiple standards are recommended because they provide more reliable calibration curves. An increase of sample uptake rate and integration time could improve detection limits. However, an improvement with increased integration time on detection limits was not observed because the auto integration mode was used.
Resumo:
This study examined changes in the salivary concentrations of immunoglobulin A (sIgA), cortisol (sC), testosterone (sT) and testosterone-to-cortisol ratio (T/C) in 23 competitive swimmers, 11-15 years old, during a week leading to competition as compared to a control (non-competitive) week. Results showed no effect of week or day, and no significant week-by-day interaction for sIgA, sC and T/C. In contrast, sT significantly decreased during the week of competition, along with a 7%, non-significant decrease in the weekly T/C. The latter suggests that the swimmers were in a catabolic state due to their training, but this did not have a negative effect on their performance Since sC did not change over the two weeks and according to the sport anxiety scale, competition stress was relatively low in these peri-pubertal athletes, it is concluded that in the absence of high cortisol levels mucosal immunity is unaffected in young athletes prior to competition.
Resumo:
The purpose of this study was to examine the acute hormonal responses to a bout of resistance versus plyometric exercise in young male athletes. Specifically, changes in salivary cortisol, testosterone and testosterone-to-cortisol ratio from pre- to post-exercise between the two different exercise protocols were examined. Twenty-six peri-pubertal active boys participated in this cross-over study, completing two exercise sessions. During each session, participants first completed a 30 min control period, which did not include any exercise, and then was randomly assigned to perform a 45 min of either a resistance exercise or a plyometric exercise protocol. All participants crossed over to perform the other exercise protocol during their second exercise session, a week later. Four saliva samples during each protocol were taken at: baseline, pre-exercise, 5 min post-exercise and 30 min post-exercise. Significant increases in testosterone values were reported 5 min post-exercise following the resistance protocol, but not the plyometric protocol. Both exercise protocols resulted in significant cortisol decreases overtime, as well as significant testosterone-to-cortisol ratio increases. The post-exercise increases in salivary testosterone and testosterone-to-cortisol ratio followed the typical exercise induced anabolic response seen in adults. However, the post-exercise decrease in salivary cortisol was different than the typical adult response indicating an insufficient stimulus for this age group maybe due to their stage of the biological development. Thus, in the adolescent boys, exercise appears to change the anabolic to catabolic balance in favor of anabolism.