3 resultados para partial least-squares regression

em Brock University, Canada


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Digital Terrain Models (DTMs) are important in geology and geomorphology, since elevation data contains a lot of information pertaining to geomorphological processes that influence the topography. The first derivative of topography is attitude; the second is curvature. GIS tools were developed for derivation of strike, dip, curvature and curvature orientation from Digital Elevation Models (DEMs). A method for displaying both strike and dip simultaneously as colour-coded visualization (AVA) was implemented. A plug-in for calculating strike and dip via Least Squares Regression was created first using VB.NET. Further research produced a more computationally efficient solution, convolution filtering, which was implemented as Python scripts. These scripts were also used for calculation of curvature and curvature orientation. The application of these tools was demonstrated by performing morphometric studies on datasets from Earth and Mars. The tools show promise, however more work is needed to explore their full potential and possible uses.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this study was to identify the impact of stressors and offsetting satistiers, measured in this study with Stress Offset Score (SOS), on intentions to quit and examine the mediating and moderating effects of three facets of work satisfaction (job satisfaction, pay satisfaction, and satisfaction with supervisor) and two facets of organizational commitment (affective and nonnative commitment) on this relationship. The sample was composed of 2990 employees from 21 public and private organizations. The interaction of each type of work satisfaction and organizational commitment, with SOS, was tested using Ordinary Least Squares (OLS) procedures. Intentions to quit was the dependent variable. The research questions were determine: (1) Does SOS predict intentions to quit? (2) Does work satisfaction mediate the predictive relationship of SOS on intentions to quit? (3) Does organizational commitment mediate the predictive relationship of SOS on intent to quit? (4) Does work satisfaction moderate the predictive relationship of SOS on intentions to quit? and (5) Does organizational commitment moderate the predictive relationship of SOS on intentions to quit? The results indicated that SOS was negatively correlated with intentions to quit. Each of the types of work satisfaction and organizational commitment variables showed a partial mediated relationship with SOS and each relationship was highly significant, while normative commitment explained more of the relationship then other mediators. The study also tested for interactions but no statistical significant relationships where established between any of the interaction terms (e.g., SOSxJob Satisfaction and SOSxAffcctive Commitment) and intentions to quit.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simple, low-cost concentric capillary nebulizer (CCN) was developed and evaluated for ICP spectrometry. The CCN could be operated at sample uptake rates of 0.050-1.00 ml min'^ and under oscillating and non-oscillating conditions. Aerosol characteristics for the CCN were studied using a laser Fraunhofter diffraction analyzer. Solvent transport efficiencies and transport rates, detection limits, and short- and long-term stabilities were evaluated for the CCN with a modified cyclonic spray chamber at different sample uptake rates. The Mg II (280.2nm)/l\/lg 1(285.2nm) ratio was used for matrix effect studies. Results were compared to those with conventional nebulizers, a cross-flow nebulizer with a Scott-type spray chamber, a GemCone nebulizer with a cyclonic spray chamber, and a Meinhard TR-30-K3 concentric nebulizer with a cyclonic spray chamber. Transport efficiencies of up to 57% were obtained for the CCN. For the elements tested, short- and long-term precisions and detection limits obtained with the CCN at 0.050-0.500 ml min'^ are similar to, or better than, those obtained on the same instrument using the conventional nebulizers (at 1.0 ml min'^). The depressive and enhancement effects of easily ionizable element Na, sulfuric acid, and dodecylamine surfactant on analyte signals with the CCN are similar to, or better than, those obtained with the conventional nebulizers. However, capillary clog was observed when the sample solution with high dissolved solids was nebulized for more than 40 min. The effects of data acquisition and data processing on detection limits were studied using inductively coupled plasma-atomic emission spectrometry. The study examined the effects of different detection limit approaches, the effects of data integration modes, the effects of regression modes, the effects of the standard concentration range and the number of standards, the effects of sample uptake rate, and the effect of Integration time. All the experiments followed the same protocols. Three detection limit approaches were examined, lUPAC method, the residual standard deviation (RSD), and the signal-to-background ratio and relative standard deviation of the background (SBR-RSDB). The study demonstrated that the different approaches, the integration modes, the regression methods, and the sample uptake rates can have an effect on detection limits. The study also showed that the different approaches give different detection limits and some methods (for example, RSD) are susceptible to the quality of calibration curves. Multicomponents spectral fitting (MSF) gave the best results among these three integration modes, peak height, peak area, and MSF. Weighted least squares method showed the ability to obtain better quality calibration curves. Although an effect of the number of standards on detection limits was not observed, multiple standards are recommended because they provide more reliable calibration curves. An increase of sample uptake rate and integration time could improve detection limits. However, an improvement with increased integration time on detection limits was not observed because the auto integration mode was used.