5 resultados para lower semi-continuous maps and functions
em Brock University, Canada
Resumo:
Although medium sized, muscular vessels normally respond to sympathetic stimulation by reducing compliance, it is unclear whether the large brachial artery is similarly affected by sympathetic stimulation induced via lower-body negative pressure (LBNP). Similarly, the impact of flow-mediated dilation (FMD) on brachial artery compliance and distensibility remains unresolved, hi addition, before such measures can be used as prognostic tools, it is important to investigate the reliability and repeatability of both techniques. Using a randomized order design, the effects of LBNP and FMD on the mechanical properties of the brachial artery were examined in nine healthy male subjects (mean age 24y). Non-invasive Doppler ultrasound and a Finometer were used to measure simultaneously the variation in systolic and diastolic diameter, and brachial blood pressure, respectively. These values were used to calculate compliance and distensibility values at baseline, and during both LBNP and FMD. The within-day and between-day repeatability of arterial diameter, compliance, distensibility, and FMD measures were assessed using the error coefficient and intra-class correlation coefficient (ICC). While heart rate (P<0.01) and peripheral resistance increased during LBNP (P<0.05), forearm blood flow and pulse pressure decreased (P<0.01). hi terms of mechanical properties, vessel diameters decreased (P<0.05), but both compliance and distensibility were not changed. On the other hand, FMD resulted in a significant increase in diameter (P<0.001), with no change in compliance or distensibility. hi summary, LBNP and FMD do not appear to alter brachial artery compliance or distensibility in young, healthy males. Whereas measures ofFMD were not found to be repeatable between days, the ICC indicated that compliance and distensibility were repeatable only within-day.
Resumo:
Trilobites ¥tere collected from Ordovician and Devonian formations of Ontario} New York} Ohio} Oklahoma} and Indiana. Diversity was generally low} but 19..?telllS and Ph..~tY>ps ¥tere the most abundant species from the Ordovician and Devonian} respectively. Recent marine arthropods ¥tere collected from the Atlantic shore of the middle Florida Keys} and from the Pacific and lagoonal waters at Cape Beale} B. C. Fresh-water arthropods were collected along the shore of the Severn River in northcentral Ontario. Cuticles ¥tere analyzed for major} minor and trace elements, 180 and 13C isotopes, as ¥tell as examined by scanning electron micr?scope to identify original and diagenetic fabrics. Examination of trilobite cuticles by scanning electron microscope revealed several microstructures consistent with those observed in Recent arthropods. Microstructures} such as setae and tegumental gland duct openings} in like sized Lim/IllS and Isoteline trilobites may indicate common ancestral origins for these organisms, or simply parallel cuticle evolutions. The dendritic microstructure, originally' thought to be a diagenetic indicator, was found in Recent specimens and therefore its presence in trilobites may be suggestive of the delicate nature of diagenesis in trilobites. The absence of other primary microstructures in trilobites may indicate alteration, taxonomic control} or that there is some inherent feature of S EM examination which may' not allow detection of some features} while others are apparently visit·le onl~1 under SH.·1. The region of the cuticle sampled for examination is also a major influence in detecting pristine microstructures, as not all areas of trilobite and Recent arthropod cuticles will have microstructures identifiable in a SEM study. Subtleties in the process of alteration, however} ma~·· leave pristine microstructures in cuticles that are partial~/ silicified or do 10m itized, and degree and type of alteration may vary stratigraphically and longitudinally within a unit. The presence of fused matrices, angular calcite rhombs, and pyrite in the cuticle are thought to be indicative of altered cuticles, although pyritization may not affect the entire cuticle. t-~atural processes in Recent arthropods, such as molting, lead to variations in cuticle chemistries, and are thought to reflect the area of concentration of the elements during calcification. The level of sodium in Recent arthropods was found to be higher than that in trilobites, but highly mobile when sUbjected to the actions of VY'€'athering. Less saline water produced lovy'€'r magnesium and higher calcium values in Recent specimens .. and metal variations in pristine Ordovician trilobite cuticle appears to follow the constraints outlined for Recent arthropods, of regulation due to the chemislry of the surrounding medium. In diagenetic analysis, sodium, strontium and magnesium proved most beneficial in separating altered from least altered trilobites. Using this criterion, specimens from shale show the least amount of geochemical alteration, and have an original mineralogy of 1.7 - 2.4 mole % MgC03 (8000 t(> 9500 ppm magnesium) for both /s>..?/e/11S lJA'i.riff!11S and PseIAit'11J17ites I..itmirpin..itl/~ and 2.8 - 3.3 mole % MgC03 (5000 to 7000 ppm magnesium) for Ph.i{).?PS This is Slightly lower than the mineralogy of Recent marine arthropods (4.43 - 12.1 mole % MgC03), and slightly higher than that of fresh-water crayfish (0.96 - 1.82 mole % MgC03). Geochemically pristine trilobites were also found to possess primary microstructures. Stable isotope values and trends support the assertion that marine-meteoriclburial fluids were responsible for the alteration observed in a number of the trilobite specimens. The results of this stUdy suggest that fossil material has to be evaluated separately along taxonomic and lithological lines to arrive at sensible diagenetic and e nvironmenta I interpretations.
Resumo:
Linear alkylbenzenes, LAB, formed by the Alel3 or HF catalyzed alkylation of benzene are common raw materials for surfactant manufacture. Normally they are sulphonated using S03 or oleum to give the corresponding linear alkylbenzene sulphonates In >95 % yield. As concern has grown about the environmental impact of surfactants,' questions have been raised about the trace levels of unreacted raw materials, linear alkylbenzenes and minor impurities present in them. With the advent of modem analytical instruments and techniques, namely GCIMS, the opportunity has arisen to identify the exact nature of these impurities and to determine the actual levels of them present in the commercial linear ,alkylbenzenes. The object of the proposed study was to separate, identify and quantify major and minor components (1-10%) in commercial linear alkylbenzenes. The focus of this study was on the structure elucidation and determination of impurities and on the qualitative determination of them in all analyzed linear alkylbenzene samples. A gas chromatography/mass spectrometry, (GCIMS) study was performed o~ five samples from the same manufacturer (different production dates) and then it was followed by the analyses of ten commercial linear alkylbenzenes from four different suppliers. All the major components, namely linear alkylbenzene isomers, followed the same elution pattern with the 2-phenyl isomer eluting last. The individual isomers were identified by interpretation of their electron impact and chemical ionization mass spectra. The percent isomer distribution was found to be different from sample to sample. Average molecular weights were calculated using two methods, GC and GCIMS, and compared with the results reported on the Certificate of Analyses (C.O.A.) provided by the manufacturers of commercial linear alkylbenzenes. The GC results in most cases agreed with the reported values, whereas GC/MS results were significantly lower, between 0.41 and 3.29 amu. The minor components, impurities such as branched alkylbenzenes and dialkyltetralins eluted according to their molecular weights. Their fragmentation patterns were studied using electron impact ionization mode and their molecular weight ions confirmed by a 'soft ionization technique', chemical ionization. The level of impurities present i~ the analyzed commercial linear alkylbenzenes was expressed as the percent of the total sample weight, as well as, in mg/g. The percent of impurities was observed to vary between 4.5 % and 16.8 % with the highest being in sample "I". Quantitation (mg/g) of impurities such as branched alkylbenzenes and dialkyltetralins was done using cis/trans-l,4,6,7-tetramethyltetralin as an internal standard. Samples were analyzed using .GC/MS system operating under full scan and single ion monitoring data acquisition modes. The latter data acquisition mode, which offers higher sensitivity, was used to analyze all samples under investigation for presence of linear dialkyltetralins. Dialkyltetralins were reported quantitatively, whereas branched alkylbenzenes were reported semi-qualitatively. The GC/MS method that was developed during the course of this study allowed identification of some other trace impurities present in commercial LABs. Compounds such as non-linear dialkyltetralins, dialkylindanes, diphenylalkanes and alkylnaphthalenes were identified but their detailed structure elucidation and the quantitation was beyond the scope of this study. However, further investigation of these compounds will be the subject of a future study.