5 resultados para lead-cadmium fluoride
em Brock University, Canada
Resumo:
A flow injection hydride generation direct current plasma atomic emission spectrometric (FI-HG-DCP-AES) method was developed for the determination of lead at ng.ml-l level. Potassium ferricyanide (K3Fe(CN)6) was used along with sodium tetrahydroborate(III) (NaBH4) to produce plumbane (PbH4) in an acid medium. The design of a gas-liquid separator (hydride generator) was tested and the parameters of the flow injection system were optimized to achieve a good detection limit and sample throughput. The technique developed gave a detection limit of 0.7 ng.ml-l(3ob). The precision at 20 ng.ml"* level was 1.6 % RSD with 1 1 measurements (n=l 1). Volume of sample loop was 500 |J.l. A sample throughput of 120 h"^ was achieved. The transition elements, Fe(II), FeOH), Cd(n), Co(II), Mn(n), Ni(II) and Zn(n) do not interfere in this method but 1 mg,l'l Cu(II) will suppress 50 % of the signal from a sample containing 20 ng.ml'l Pb. This method was successfully applied to determine lead in a calcium carbonate (CaC03) matrix of banded coral skeletons from Si-Chang Island in Thailand.
Resumo:
Modifications to the commercial hydride generator, manufactured by Spectrametrics, resulted in improved operating procedure and enhancement of the arsenic and germanium signals. Experiments with arsenic(III) and arsenic(V) showed that identical reiults could be produced from both oxidation states. However, since arsenic(V) is reduced more slowly than arsenic(III), peak areas and not peak heights must be measured when the arsine is immediately stripped from the system (approximately 5 seconds reaction). When the reduction is allowed to proceed for 20 seconds before the arsine is stripped, peak heights may be used. For a 200 ng/mL solution, the relative standard deviation is 2.8% for As(III) and 3.8% for As(V). The detection limit for arsenic using the modified system is 0.50 ng/mL. Studies performed on As(V) standards show that the interferences from 1000 mg/L of nickel(II), cobalt(II), iron(III), copper(II), cadmium(II), and zinc(II) can be eliminated with the aid of 5 M Hel and 3% L-cystine. Conditions for the reduction of germanium to the corresponding hydride were investigated. The effect of different concentrations of HCl on the reduction of germanium to the covalent hydride in aqueous media by means of NaBH 4 solutions was assessed. Results show that the best response is accomplished at a pH of 1.7. The use of buffer solutions was similarly characterized. In both cases, results showed that the element is best reduced when the final pH of the solution after reaction is almost neutral. In addition, a more sensitive method, which includes the use of (NH4)2S208' has been developed. A 20% increase in the germanium signal is registered when compared to the signal achieved with Hel alone. Moreover, under these conditions, reduction of germanium could be accomplished, even when the solution's pH is neutral. For a 100 ng/mL germanium standard the rsd is 3%. The detection limit for germanium in 0.05 M Hel medium (pH 1.7) is 0.10 ng/mL and 0.09 ng/mL when ammonium persulphate is used in conjunction with Hel. Interferences from 1000 mg/L of iron(III), copper(II), cobalt(II), nickel(II), cadmium(II), lead(II), mercury(II), aluminum(III), tin(IV), arsenic(III), arsenic(V) and zinc(II) were studied and characterized. In this regard, the use of (NH4)ZS20S and Hel at a pH of 1.7 proved to be a successful mixture in the sbppression of the interferences caused by iron, copper, aluminum, tin, lead, and arsenic. The method was applied to the determination of germanium in cherts and iron ores. In addition, experiments with tin(IV) showed that a 15% increase in the tin signal can be accomplished in the presence of 1 mL of (NH4)2S20S 10% (m/V).
Resumo:
Systems such as MF/diol (M = alkali metal) and }1F/carboxylic acid were subjected to IH, I9F and 13C nmr study to investigate the nature of the very strong H-bonding of fluoride ions with these systems. Evidence indicates a strong H-bond in diol-fluoride systems (~H ~ -(56) kJ mol-I) which is stronger than most 'typical' H-bonds (~H = -(12-40) kJ mol-I), but weaker than that reported for carboxylic acid-fluoride systems (~H ~ -(120) kJ mol-I). Approximate fluoride H-bonded shifts (o(OH)OHF) were evaluated for MF/diol systems from IH chemical shift measurements. No direct correlation was observed between I9F chemical shift and H-bond strength. Thermodynamic parameters were calculated from temperature dependent IH and 19F shifts. Preliminary studies of BUn 4NF-acetylacetone by I9F nmr were conducted at low temperatures and a possible Jmax (ca. 400 Hz) is reported for the fluoride ion H-bonded to acetylacetone. Highfield shift for non-protonated carbons and downfield shift for protonated carbons were observed in carboxylic acid/KF systems. Significant decreas$in I3C TI due to strong H-bonding to fluoride ions were also detected in both diol and carboxylic acid systems. Anomalous results were obtained, such as increasing NOE with increasing temperature in neat 1,2-ethanediol (values above the theoretical maximum of 1.988) and in 1,2-ethanediol/KF. The large 13C NOE's for carboxy carbons in neat carboxylic acids which are. further enhanced by the addition of KF are also unusual.
Resumo:
Nanoporous materials with large surface area and well-ordered pore structure have been synthesized. Thiol groups were grafted on the materials' surface to make heavy metal ion pre-concentration media. The adsorption properties ofthe materials were explored. Mercury, gold and silver can be strongly adsorbed by these materials, even in the presence of alkaline earth metal ion. Though the materials can adsorb other heavy metal ions such as lead and copper, they show differential adsorption ability when several ions are present in solution. The adsorption sequence is: mercury> == silver> copper » lead and cadmium. In the second part of this work, the memory effects of mercury, gold, silver and boron were investigated. The addition of 2% L-cysteine and 1% thiourea eliminates the problems of the three metal ions completely. The wash-out time for mercury dropped from more than 20 minutes to 18 seconds, and the wash-out time for gold decreased from more than 30 minutes to 49 seconds. The memory effect of boron can be reduced by the use of mannitol.
Resumo:
Landscape geochemical investigations were conducted upon portions of a natural uniform landscape in southern Norway. This consisted of sampling both soil profile samples and spruce tree twigs for the analysis of twelve chemical elements. These elements were cobalt, copper, nickel, lead, zinc, manganese, magnesium, iron, calcium, sodium, potassium and aluminum which were determined by atomic absorption analysis on standardized extraction techniques for both organic and inorganic materials. Two "landscape traverses" were chosen for a comparative study of the effects of varying landscape parameters upon the trace element distribution patterns throughout the landscape traverses. The object of this study was to test this method of investigation and the concept of an ideal uniform landscape under Norwegian conditions. A "control traverse" was established to represent uniform landscape conditions typical of the study area and was used to determine "normal" or average trace element distribution patterns. A "signal traverse" was selected nearby over an area of lead mineralization where the depth to bedrock is very small. The signal traverse provided an area of similar landscape conditions to those of the control traverse with significant differences in the bedrock configuration and composition. This study was also to determine the effect of the bedrock mineralization upon the distribution patterns of the twelve chemical elements within the major components of the two landscape traverses (i.e. soil profiles and tree branches). The lead distribution within the soils of the signal traverse showed localized accumulations of lead within the overburden with maximum values occurring within the organic A horizon of soil profile #10. Above average concentrations of lead were common within the signal traverse, however, the other elements studied were not significantly different from those averages determined throughout the soils of the control traverse. The spruce twig samples did not have corresponding accumulations of lead near the soil lead anomaly. This is attributable to the very localized nature of the lead dispersion pattern within the soils. This approach to the study of the geochemistry of a natural landscape was effective in establishing: a) average or "normal" trace element distribution patterns b) local variations in the landscape morphology and c) the effect of unusually high lead concentrations upon the geochemistry of the landscape (i.e. within the soil profiles and tree branches). This type of study provides the basis for further more intensive studies and serves only as a first approximation of the behaviour of elements within a natural landscape.