3 resultados para internal information flow
em Brock University, Canada
Resumo:
We assess the predictive ability of three VPIN metrics on the basis of two highly volatile market events of China, and examine the association between VPIN and toxic-induced volatility through conditional probability analysis and multiple regression. We examine the dynamic relationship on VPIN and high-frequency liquidity using Vector Auto-Regression models, Granger Causality tests, and impulse response analysis. Our results suggest that Bulk Volume VPIN has the best risk-warning effect among major VPIN metrics. VPIN has a positive association with market volatility induced by toxic information flow. Most importantly, we document a positive feedback effect between VPIN and high-frequency liquidity, where a negative liquidity shock boosts up VPIN, which, in turn, leads to further liquidity drain. Our study provides empirical evidence that reflects an intrinsic game between informed traders and market makers when facing toxic information in the high-frequency trading world.
Resumo:
This case study examines the impact of a computer information system as it was being implemented in one Ontario hospital. The attitudes of a cross section of the hospital staff acted as a barometer to measure their perceptions of the implementation process. With The Mississauga Hospital in the early stages of an extensive computer implementation project, the opportunity existed to identify staff attitudes about the computer system, overall knowledge and compare the findings with the literature. The goal of the study was to develop a greater base about the affective domain in the relationship between people and the computer system. Eight exploratory questions shaped the focus of the investigation. Data were collected from three sources: a survey questionnaire, focused interviews, and internal hospital documents. Both quantitative and qualitative data were analyzed. Instrumentation in the study consisted of a survey distributed at two points in time to randomly selected hospital employees who represented all staff levels.Other sources of data included hospital documents, and twenty-five focused interviews with staff who replied to both surveys. Leavitt's socio-technical system, with its four subsystems: task, structure, technology, and people was used to classify staff responses to the research questions. The study findings revealed that the majority of respondents felt positive about using the computer as part of their jobs. No apparent correlations were found between sex, age, or staff group and feelings about using the computer. Differences in attitudes, and attitude changes were found in potential relationship to the element of time. Another difference was found in staff group and perception of being involved in the decision making process. These findings and other evidence about the role of change agents in this change process help to emphasize that planning change is one thing, managing the transition is another.
Resumo:
Flow injection analysis (FIA) was applied to the determination of both chloride ion and mercury in water. Conventional FIA was employed for the chloride study. Investigations of the Fe3 +/Hg(SCN)2/CI-,450 nm spectrophotometric system for chloride determination led to the discovery of an absorbance in the 250-260 nm region when Hg(SCN)2 and CI- are combined in solution, in the absence of iron(III). Employing an in-house FIA system, absorbance observed at 254 nm exhibited a linear relation from essentially 0 - 2000 Jlg ml- 1 injected chloride. This linear range spanning three orders of magnitude is superior to the Fe3+/Hg(SCN)2/CI- system currently employed by laboratories worldwide. The detection limit obtainable with the proposed method was determin~d to be 0.16 Jlg ml- 1 and the relative standard deviation was determined to be 3.5 % over the concentration range of 0-200 Jig ml- 1. Other halogen ions were found to interfere with chloride determination at 254 nm whereas cations did not interfere. This system was successfully applied to the determination of chloride ion in laboratory water. Sequential injection (SI)-FIA was employed for mercury determination in water with the PSA Galahad mercury amalgamation, and Merlin mercury fluorescence detection systems. Initial mercury in air determinations involved injections of mercury saturated air directly into the Galahad whereas mercury in water determinations involved solution delivery via peristaltic pump to a gas/liquid separator, after reduction by stannous chloride. A series of changes were made to the internal hardware and valving systems of the Galahad mercury preconcentrator. Sequential injection solution delivery replaced the continuous peristaltic pump system and computer control was implemented to control and integrate all aspects of solution delivery, sample preconcentration and signal processing. Detection limits currently obtainable with this system are 0.1 ng ml-1 HgO.