6 resultados para heavy disk
em Brock University, Canada
Resumo:
This investigation of geochemistry and mineralogy of heavy metals in fine grained (<63^m) sediment of the Welland River was imdertaken to: 1) describe metal dispersion patterns relative to a source, identify minerals forming and existing at the outfall region and relate sediment particle size to chemistry; 2) to delineate sample handling, preparation and evaluate, modify and develop analytical methods for heavy metal analysis of complex environmental samples. Ajoint project between Brock University and Geoscience Laboratories was initiated to test a contaminated site of the Welland River at the base of Atlas Speciality Steels Co. Methods were developed and utilized for particle size separation and two acid extraction techniques: 1) Partial extraction; 2) Total extraction. The mineralogical assessment identified calcite, dolomite, quartz and clays. These minerals are typical of the carbonate-shale rock basement of the Niagara Peninsula. Minerals such as, mullite and ferrocolumbite were found at the outfall region. These are not typical of the local geology and are generally associated with industrial pollutants. Partial and total extraction techniques were used to characterize the sediments based on chemical distribution, elemental behaviour and analytical differences. The majority of elements were lower in concentration in the partial extraction technique; suggesting these elements are bound in an acid extractable phase (exchangeable, organic and carbonate phases). The total extraction technique yielded higher elemental concentrations taking difficult oxides and silicates into solution. Geochemical analyses of grain size separates revealed that heavy metal (Co, Ni, V, Mn, Fe, Ba) concentrations did not increase with decreasing grain size. This is a function of the anthropogenic mill scale input into the river. The background elements (Sc, Y, Sr, Mg, Al and Ti) showed an increase in concentration to the finest grain size suggesting that it is directly related to the local mineralogy and geology. Dispersion patterns ofmetals fall into two distinct categories: 1) the heavy metals (Co, Cu, Ni, Zn, V and Cr), and 2) the background elements (Be, Sc, Y, Sr, Al and Ti). The heavy metals show a marked increase in the outfall region, while the background elements show a significant decrease at the outfall. This pattern is attributed to a "dilution effect" ofthe natural sediments by the anthropogenic mill scale sediments. Multivariant statistical analysis and correlation coefficient matrix results clearly support these results and conclusions. These results indicate the outfall region ofthe Welland River is highly contaminated with to heavy metals from the industrialized area of Welland. A short distance downstream, the metal concentrations return to baseline geochemical levels. It appears, contaminants rapidly come out of suspension and are deposited in close proximity to the source. Therefore, it is likely that dredging the sediment from the river may cause resuspension of contaminated sediments, but may not distribute the sediment as far as initially anticipated.
Resumo:
Microwave digestions of mercury in Standards Reference Material (SRM) coal samples with nitric acid and hydrogen peroxide in quartz vessels were compared with Teflon® vessel digestion by using flow injection cold vapor atomic absorption spectrometry. Teflon® vessels gave poor reproducibiUty and tended to deliver high values, while the digestion results from quartz vessel show good agreement with certificate values and better standard deviations. Trace level elements (Ag, Ba, Cd, Cr, Co, Cu, Fe, Mg, Mn, Mo, Pb, Sn, Ti, V and Zn) in used oil and residual oil samples were determined by inductively coupled plasma-optical emission spectrometry. Different microwave digestion programs were developed for each sample and most of the results are in good agreement with certified values. The disagreement with values for Ag was due to the precipitation of Ag in sample; while Sn, V and Zn values had good recoveries from the spike test, which suggests that these certified values might need to be reconsidered. Gold, silver, copper, cadmium, cobalt, nickel and zinc were determined by continuous hydride generation inductively coupled plasma-optical emission spectrometry. The performance of two sample introduction systems: MSIS™ and gas-liquid separator were compared. Under the respective optimum conditions, MSIS^"^ showed better sensitivity and lower detection limits for Ag, Cd, Cu, Co and similar values for Au, Ni and Zn to those for the gas-liquid separator.
Resumo:
Temperature dependent resistivity, p, magnetic susceptibility, X, and far-infrared reflectance measurements were made on the low Tc superconductor UBe13. Two variants of UBe13 have been proposed, named 'L'- (for low Tc ) and 'H'-type (for high Tc ). Low temperature resistivity measurements confirmed that our sample was of H-type and that the transition temperature was at 0.9 K. This was further confirmed with the observation of this transition in the AC-susceptibility. Low temperature reflectance measurements showed a decrease in the reflectivity as the temperature is lowered from 300 to 10 K, which is in qualitative agreement with the increasing resistivity in this temperature range as temperature is lowered. No dramatic change in the reflectivity was observed between 10 and 0.75 K. A further decrease of the reflectance was observed for the temperature of 0.5 K. The calculated optical conductivity shows a broad minimum near 80 cm-1 below 45 K. Above 45 K the conductivity is relatively featureless. As the temperature is lowered, the optical conductivity decreases. The frequency dependent scattering rate was found to be flat for temperatures between 300 and 45 K. The development of a peak, at around 70 cm-1 was found for temperatures of 45 K and below. This peak has been associated with the energy at which the transition to a coherent state occurs from single impurity scattering in other heavy fermion systems. The frequency dependent mass enhancement coefficient was found to increase at low frequencies as the frequency decreases. Its' magnitude as frequency approaches zero also increased as the temperature decreased.
Resumo:
The optical response to far infrared radiation has been measured on a mosaic of heavy fermion CeColnssingle crystals. The superconducting transition temperature of the crystals has been determined by van der Pauw resistivity and ac-susceptibility measurements as Tc = 2.3 K. The optical measurements were taken above and below the transition temperature using a 3He cryostat and step and integrate Martin-Puplett type polarizing interferometer. The absolute reflectance of the heavy fermion CeColns in the superconducting state in range (0, 100)cm-1 was calculated from the measured thermal reflectance, using the normal state data of Singley et al and a low frequency extrapolation for a metallic material in the Hagen-Rubens regime. By means of Kramers-Kronig analysis the absolute reflectance was used to calculate the optical conductivity of the sample. The real part of the calculated complex conductivity 0-(w) ofCeColns indicates a possible opening of an energy gap close to 50 em-I.
Resumo:
The optical response to far infrared radiation has been measured on a mosaic of heavy fermion CeCoIns single crystals. The superconducting transition temperature of the crystals has been determined by van der Pauw resistivity and ac-susceptibility measurements as Tc = 2.3 K. The optical measurements were taken above and below the transition temperature using a ^He cryostat and step and integrate Martin-Puplett type polarizing interferometer. The absolute reflectance of the heavy fermion CeCoIns in the superconducting state in range (0, 100)cm~^ was calculated from the measured thermal reflectance, using the normal state data of Singley et al and a low frequency extrapolation for a metallic material in the Hagen-Rubens regime. By means of Kramers-Kronig analysis the absolute reflectance was used to calculate the optical conductivity of the sample. The real part of the calculated complex conductivity a{u)) of CeCoIns indicates a possible opening of an energy gap close to 50 cm~^.
Resumo:
Objective: To determine which socio-demographic, exposure, morbidity and symptom variables are associated with health-related quality of life among former and current heavy smokers. Methods: Cross sectional data from 2537 participants were studied. All participants were at ≥2% risk of developing lung cancer within 6 years. Linear and logistic regression models utilizing a multivariable fractional polynomial selection process identified variables associated with health-related quality of life, measured by the EQ-5D. Results: Upstream and downstream associations between smoking cessation and higher health-related quality of life were evident. Significant upstream associations, such as education level and current working status and were explained by the addition of morbidities and symptoms to regression models. Having arthritis, decreased forced expiratory volume in one second, fatigue, poor appetite or dyspnea were most highly and commonly associated with decreased HRQoL. Discussion: Upstream factors such as educational attainment, employment status and smoking cessation should be targeted to prevent decreased health-related quality of life. Practitioners should focus treatment on downstream factors, especially symptoms, to improve health-related quality of life.