3 resultados para grating acuity
em Brock University, Canada
Resumo:
A Czerny Mount double monochromator is used to measure Raman scattered radiation near 90" from a crystalline, Silicon sample. Incident light is provided by a mixed gas Kr-Ar laser, operating at 5145 A. The double monochromator is calibrated to true wavelength by comparison of Kr and Ar emission Une positions (A) to grating position (A) display [1]. The relationship was found to be hnear and can be described by, y = 1.219873a; - 1209.32, (1) where y is true wavelength (A) and xis grating position display (A). The Raman emission spectra are collected via C"*""*" encoded software, which displays a mV signal from a Photodetector and allows stepping control of the gratings via an A/D interface. [2] The software collection parameters, detector temperature and optics are optimised to yield the best quality spectra. The inclusion of a cryostat allows for temperatmre dependent capabihty ranging from 4 K to w 350 K. Silicon Stokes temperatm-e dependent Raman spectra, generally show agreement with Uterature results [3] in their frequency haxdening, FWHM reduction and intensity increase as temperature is reduced. Tests reveal that a re-alignment of the double monochromator is necessary before spectral resolution can approach literature standard. This has not yet been carried out due to time constraints.
Resumo:
As a result of the current changes taking place in the delivery of acute care services, the emergence of acute ambulatory care (AAC) settings is expanding. According to a literature review, the volume, acuity, and complexity of patient care in these settings is increasing while the time the patients spend under the care of nurses is decreasing. Two forces, hospital downsizing and advancing technology, are identified as the major contributors to the shift in acute care delivery. The effects that these changes are having on the clinical nursing practice of registered nurses working in AAC settings are not known. Given that AAC settings are rapidly expanding, it can be anticipated that the delivery of nursing care will continue to be compressed into a shorter time frame. Therefore, the following qualitative research question was formulated: What are the problems and issues related to clinical nursing practice in acute ambulatory settings? The purpose of this study was to explore the problems and issues associated with change and clinical nursing practice including the educational needs of nurses working in MC settings. Specific objectives of the study included the following: (a) to explore the problems and issues related to nursing practice in select AAC settings; (b) to explore the similarities and differences in perspectives related to role expectation between nurse managers, nurse educators, and staff nurses; and (c) to develop a conceptual framework that will guide the construction of an instrument needed for further research. This study used semistructured individual interviews and focus group sessions to collect data from the three categories of registered nurses. More specifically, data were collected from one nurse manager, two charge nurses, two nurse educators and fifteen staff nurses, working in three different MC settings of a major teaching hospital. Collected data were separately analyzed by the researcher and an external rater following grounded theory methodology. By using open and axial coding, the problems and issues identified by nurses were grouped into several major and minor themes. In final analysis, by using selective coding, the four core themes (intensification, moderation, frustration, and adaptation) were extracted. Each core theme was presented and discussed in relation to hospital downsizing and advancing technology. The relationships among the four core themes were discussed and depicted in a model termed the "Impact and Consequence Model on Nursing Practice in MC Settings." Implications for further research are discussed and research hypotheses, based on the research findings, are presented.
Resumo:
The 3700 A - 3000 A absorption spectra of CH3CHO and its isotopic compounds such as CH3CDO, CD3CHO and CD3CDO were studied in the gas phase at room temperature and low temperatures. The low resolution spectra of the compounds were recorded by a 1.5 m Baush and Lomb grating spectrograph. The high resolution spectra were recorded by a Ebert spectrograph with the Echelle grating and the holographic grating separately. The multiple reflection cells were used to achieve the long path length. The pressure-path length used for the absorption spectrum of CH 3CHO was up to 100 mm Hg )( 91 . 43mo The emission spectrum and the excitation spectrum of CH3CHO were also recorded in this research. The calculated satellite band patterns \vhich were ob-tailied by the method of Lewis were used to compare with the observed near UV absorption spectrum of acetaldehyde. These calculated satellite band patterns belonged to two cases: namely, the barriers-in-phase case and the barriers- out-of-phase case. Each of the calculated patterns corresponded to a stable conformation of acetaldehyde in the excited state . The comparisons showed that the patterns in the observed absorption spectra corresponded to the H-H eclipsed conformations of acetaldehyde in the excited state . The least squares fitting analysis showed that the barrier heights in the excited state were higher than in the ground state. Finally, the isotopic shifts for the isotopic compounds of acetaldehyde were compared to the compounds with the similar deuterium substitution.