2 resultados para Waves, Calming of.

em Brock University, Canada


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The prlmaiy objective of this study was to Identify and describe the physical and psychological stress factors that elementary school teachers experience and how teachers cope with stress. A secondary objective was to offer boards and teachers potential coping strategies counteracting stress and the effects of stress. The sample consisted of 120 elementaiy teachers from southern Ontario. Ten elementaiy schools were randomly chosen. The Teacher Stress Inventory questionnaire (Flmian, 1989) was used. Data were analyzed using a variety of statistics. Test norms and interpretations were performed based on standard results obtained from the author of the questionnaire (Flmian, 1988). Overall, the results indicated that work-related stressors were the main factor for teacher stress. This Included such factors as caseload/class is too big, too much administrative paperwork, and having little time to prepare lessons. Implications for further research and practical suggestions for further reseairch are discussed. Also a variety of recommendations to boards and for individual use are discussed. Some recommendations are having counselling available for teachers, workshops on how to handle stress, and learning how to breathe and using calm visualization.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fermi patches in quasi-two dimensional charge density waves (CDW) have not described the connection to superconductivity (SC) according to theory adequately at this point in time. The connection between CDW and SC in the quasi-two dimensional material CuxTiSe2 is an interesting one which might reveal mechanisms in unconventional superconductors. A previous Brock graduate student grew crystals of CuxTiSe2. The precise doping of the samples was not known. In order to determine the doping parameter x in CuxTiSe2, a sensitive resistivity measurement system was necessary. A new resistivity measurement system was designed and implemented utilizing an Infrared Labs HDL-10 He3 cryostat. By comparing with data from the literature, doping of two samples was investigated using the new measurement system and a Quantum Design Magnetic Property Measurement System (MPMS). Methods for determining the doping revealed that the old resistivity system would not be able to determine the CDW transition temperature of highly doped samples or doping for elongated samples due to electronic noise. Doping in one sample was found to be between x=0.06 and x=0.065. Values of doping in the second sample had a discrepancy but could be explained by incorrect sample orientation.