2 resultados para Time Line

em Brock University, Canada


Relevância:

60.00% 60.00%

Publicador:

Resumo:

This study explored one university's response to the internationalization of higher education. Case study methodology was employed through a review of current and archival documents and interviews with key actors in the international spheres of the university. The historical, current, and future contexts were considered to situate the case study on a time line. Data analysis revealed that there were several points of division among the university community related to the response to internationalization, but also a major point of coherence in the centrality of inter-cultural understanding in efforts to internationalize. Other key findings included strengths, areas for improvement, and future directions of the university's response to internationalization. All of these findings were contextualized in findings related to the history of the university. In addition to these major findings, three themes in relation to the vision for internationalization at the institution were revealed: ( a) intercultural understanding, (b) the comprehensive status of the university, and (c) the financial benefits of internationalization. Recommendations are made for practice at the university in order to clarify this vision to develop a clear foundation from which to further build a response to internationalization that is solidly based on inter-cultural understanding, and recommendations for future research into the process of internationalization at the institutional level in Canada are suggested.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A method using L-cysteine for the determination of arsenous acid (As(III)), arsenic acid (As(V)), monomethylarsonic acid (MMAA), and dimethylarsinic acid (DMAA) by hydride generation was demonstrated. The instrument used was a d.c. plasma atomic emission spectrometer (OCP-AES). Complete recovery was reported for As(III), As(V), and DMAA while 86% recovery was reported for MMAA. Detection limits were determined, as arsenic for the species listed previously, to be 1.2, 0.8, 1.1, and 1.0 ngemL-l, respectively. Precision values, at 50 ngemL-1 arsenic concentration, were f.80/0, 2.50/0, 2.6% and 2.6% relative standard deviation, respectively. The L-cysteine reagent was compared directly with the conventional hydride generation technique which uses a potassium iodide-hydrochloric acid medium. Recoveries using L-cysteine when compared with the conventional method provided the following results: similar recoveries were obtained for As(III), slightly better recoveries were obtained for As(V) and MMAA, and significantly better recoveries for DMAA. In addition, tall and sharp peak shapes were observed for all four species when using L-cysteine. The arsenic speciation method involved separation by ion exchange .. high perfonnance liquid chromatography (HPLC) with on-line hydride generation using the L.. cysteine reagent and measurement byOCP-AES. Total analysis time per sample was 12 min while the time between the start of subsequent runs was approximately 20 min. A binary . gradient elution program, which incorporated the following two eluents: 0.01 and 0.5 mM tri.. sodium citrate both containing 5% methanol (v/v) and both at a pH of approximately 9, was used during the separation by HPLC. Recoveries of the four species which were measured as peak area, and were normalized against As(III), were 880/0, 290/0, and 40% for DMAA, MMAA and As(V), respectively. Resolution factors between adjacent analyte peaks of As(III) and DMAA was 1.1; DMAA and MMAA was 1.3; and MMAA and As(V) was 8.6. During the arsenic speciation study, signals from the d.c. plasma optical system were measured using a new photon-signal integrating device. The_new photon integrator developed and built in this laboratory was based on a previously published design which was further modified to reflect current available hardware. This photon integrator was interfaced to a personal computer through an AID convertor. The .photon integrator has adjustable threshold settings and an adjustable post-gain device.