3 resultados para Sulfuric acid solutions
em Brock University, Canada
Resumo:
2-Carboxy-2?-methyldiphenyl sulfide was prepared by the Ullmann reaction and cyclodehydrated by sulfuric acid to afford 4-methylthioxanthone. 1-Methylthioxanthone was separated from the reaction mixture obtained upon cyclodehydration of 2-carboxy-3f-methyldiphenyl sulfide. In addition, 1-, 2-, 3- and 4-methylthioxanthone 10,10-dioxides were synthesized by oxidation of the corresponding thioxanthones. o-, m- and p-N-Tolylanthranilic acids were prepared by the Ullmann reaction and used as precursors for the preparation of 1-, 2- and 4- methyl-9-chloroacridine and finally 1-, 2-, 3- and 4-methylacridone. High resolution, 60 MHz PMR spectra were obtained on the four monomethyl isomers of xanthone, thioxanthone, thioxanthone 10,10-dioxide and acridone, and on 1-, 2- and 4-methyl-9-chloroacridine. For some compounds, coupling of all three different aromatic protons to the methyl was observed, two of the couplings typically being smaller than the third. With the large (ortho) coupling being on the order of 0.5 to 1.0 Hz, it was necessary to decouple the aromatic part of the spectrum. The magnitude of the ortho benzylic constant may be related to an incomplete Tr-bond delocalization in the molecules.
Resumo:
The work in this thesis deals mainly with nucleophilic substitution of chloroanthraquinones as a route to various starting materials which might rearrange, via aryne intermediates to afford fused-ring heterocy1ic carboxylic acids. 1-Amino-5-chloroanthraquinone was successfully prepared by reacting 1,5-dichloroanthraquinone with sodium aZide in ref1uxing dimethylsulfoxide (DMSO). It could also be prepared from the same starting material by reaction with ammonia (gas) in DMSO in the presence of potassium fluoride. Treatment of l-amino-5-chloroanthraquinone with potassium amide in liquid ammonia or with potassium t-butoxide in t-butylbenzene returned mainly starting material, although in the latter case some 1-amino-5-hydroxyanthraquinone was also isolated. 1-Hydroxy-5-chloroanthraquinone was ultimately prepared by diazotization of the amino-analog. It was recovered almost quantitatively after treatmenu'with potassium amide in liquid ammonia. The reaction with potassium t-butoxide in t-buty1benzene was anomalous and gave 1-hydroxyanthraquinone as the only iso1able product. Acridines were successfully prepared by the action of 70% sulfuric acid on 1,5-bis(p-toluidino)-anthraquinone and 1-p-toluidino-5- ch10roanthraquinone, and in the latter case, cleavage to give an acridinecarboxylate was attempted. Substituted anthraquinones reacted with sodium azide in sulfuric acid to give azepindiones by -NH insertion. Methods for separating and identifying isomeric mixtures of these compounds were examined. Attempted decarbonylation of selected azepindiones to give acridones gave mainly what were thought to be amino-benzophenone derivatives. Chloroanthraquinones were found to react with hexamethylphosphoramide (HMPA) to give mixtures of the dimethylamino- and methylaminoderivatives. Under the same conditions halogeno-nitrobenzenes and nitrophenols were substituted to give the appropriate dimethyl aminobenzenes, except in two cases. 3-Chloronitrobenzene reacted anomalously to give a small amount of 3,3'-dichloroazobenzene and a trace of 4-dimethylamino-nitrobenzene. Pentachlorophenol reacted to give a pentachlorophenylphosphorodiamidate in good yield.
Resumo:
A simple, low-cost concentric capillary nebulizer (CCN) was developed and evaluated for ICP spectrometry. The CCN could be operated at sample uptake rates of 0.050-1.00 ml min'^ and under oscillating and non-oscillating conditions. Aerosol characteristics for the CCN were studied using a laser Fraunhofter diffraction analyzer. Solvent transport efficiencies and transport rates, detection limits, and short- and long-term stabilities were evaluated for the CCN with a modified cyclonic spray chamber at different sample uptake rates. The Mg II (280.2nm)/l\/lg 1(285.2nm) ratio was used for matrix effect studies. Results were compared to those with conventional nebulizers, a cross-flow nebulizer with a Scott-type spray chamber, a GemCone nebulizer with a cyclonic spray chamber, and a Meinhard TR-30-K3 concentric nebulizer with a cyclonic spray chamber. Transport efficiencies of up to 57% were obtained for the CCN. For the elements tested, short- and long-term precisions and detection limits obtained with the CCN at 0.050-0.500 ml min'^ are similar to, or better than, those obtained on the same instrument using the conventional nebulizers (at 1.0 ml min'^). The depressive and enhancement effects of easily ionizable element Na, sulfuric acid, and dodecylamine surfactant on analyte signals with the CCN are similar to, or better than, those obtained with the conventional nebulizers. However, capillary clog was observed when the sample solution with high dissolved solids was nebulized for more than 40 min. The effects of data acquisition and data processing on detection limits were studied using inductively coupled plasma-atomic emission spectrometry. The study examined the effects of different detection limit approaches, the effects of data integration modes, the effects of regression modes, the effects of the standard concentration range and the number of standards, the effects of sample uptake rate, and the effect of Integration time. All the experiments followed the same protocols. Three detection limit approaches were examined, lUPAC method, the residual standard deviation (RSD), and the signal-to-background ratio and relative standard deviation of the background (SBR-RSDB). The study demonstrated that the different approaches, the integration modes, the regression methods, and the sample uptake rates can have an effect on detection limits. The study also showed that the different approaches give different detection limits and some methods (for example, RSD) are susceptible to the quality of calibration curves. Multicomponents spectral fitting (MSF) gave the best results among these three integration modes, peak height, peak area, and MSF. Weighted least squares method showed the ability to obtain better quality calibration curves. Although an effect of the number of standards on detection limits was not observed, multiple standards are recommended because they provide more reliable calibration curves. An increase of sample uptake rate and integration time could improve detection limits. However, an improvement with increased integration time on detection limits was not observed because the auto integration mode was used.