12 resultados para Solvents.

em Brock University, Canada


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Molecular mechanics calculations were done on tetrahedral phosphine oxide zinc complexes in simulated water, benzene and hexane phases using the DREIDING II force field in the BIOGRAF molecular modeling program. The SUN workstation computer (SUN_ 4c, with SPARK station 1 processor) was used for the calculations. Experimental structural information used in the parameterization was obtained from the September 1989 version of the Cambridge Structural Database. 2 Steric and solvation energies were calculated for complexes of the type ZnCl2 (RlO)2' The calculations were done with and without inclusion of electrostatic interactions. More reliable simulation results were obtained without inclusion of charges. In the simulated gas phase, the steric energies increase regularly with number of carbons in the alkyl group, whereas they go through a maximum when solvent shells are included in the calculation. Simulated distribution ratios vary with chain length and type of chain branching and the complexes are found to be more favourable for extraction by benzene than by hexane, in accord with experimental data. Also, in line with what would be expected for a favorable extraction, calculations without electrostatics predict that the complexes are better solvated by the organic solvents than by water.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Part I - Fluorinated Compounds A method has been developed for the extraction, concentration, and determination of two unique fluorinated compounds from the sediments of Lake Ontario. These compounds originated from a common industrial landfill, and have been carried to Lake Ontario by the Niagara River. Sediment samples from the Mississauga basin of Lake Ontario have been evaluated for these compounds and a depositional trend was established. The sediments were extracted by accelerated solvent extraction (ASE) and then underwent clean-up, fractionation, solvent exchange, and were concentrated by reduction under nitrogen gas. The concentrated extracts were analyzed by gas chromatography - electron capture negative ionization - mass spectrometry. The depositional profile determined here is reflective of the operation of the landfill and shows that these compounds are still found at concentrations well above background levels. These increased levels have been attributed to physical disturbances of previously deposited contaminated sediments, and probable continued leaching from the dumpsite. Part II - Polycyclic Aromatic Hydrocarbons Gas chromatography/mass spectrometry is the most common method for the determination of polycyclic aromatic hydrocarbons (PAHs) from various matrices. Mass discrimination of high-boiling compounds in gas chromatographic methods is well known. The use of high-boiling injection solvents shows substantial increase in the response of late-eluting peaks. These solvents have an increased efficiently in the transfer of solutes from the injector to the analytical column. The effect of I-butanol, I-pentanol, cyclopentanol, I-hexanol, toluene and n-octane, as injection solvents, was studied. Higher-boiling solvents yield increased response for all PAHs. I -Hexanol is the best solvent, in terms of P AH response, but in this solvent P AHs were more susceptible to chromatographic problems such as peak splitting and tailing. Toluene was found to be the most forgiving solvent in terms of peak symmetry and response. It offered the smallest discrepancies in response, and symmetry over a wide range of initial column temperatures.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This project is focussed on the thermsLl decomposition of t-butyl hydroperoxide and sec-butyl hydroperoxide at 120°C to 160°C in three alcohol solvents. These are methanol, ethajiol and isopropyl alcohol. The aim of the project was to examine the process of induced decomposition. Thermal decomposition of t-hutyl hydroperoxide and sec-butyl hydroperoxide indicate that these reactions have first-order kinetics with activation energies on the order of 20 to 28 K cal/mole, Styrene was used as a free radical trap to inhibit the induced decomposition. The results permitted calculation of how much induced decomposition occurred in its absence. The experimental resvilts indicate that the induced decomposition is important for t-butyl hydroperoxide in alcohol solvents, as shown by both the reaction rate suid product studies. But sec-butyl hydroperoxide results show that the concerted mechanism for the interaction of two sec-butylperoxy radicals occurs in addition to the induced decomposition. Di-sodium E.D,T.A. was added to reduce possible effects of trace transition metal ion .impurities. The result of this experiment were not as expected. The rate of hydroperoxide decomposition was about the same but was zero-order in hydroperoxide concentration.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The thermal decomposition of 2,3-di~ethy l - J-hydr operox y- 1 - butene , p r epared f rol") singl e t oxygen, has been studied i n three solvents over the tempe r a ture r ange from 1500e to l o00e and t!1e i 111 t ial ~oncentrfttl nn r Ange from O. 01 M to 0.2 M. Analys i s of the kine tic data ind ica te s i nduced homolysis as the n ost probRble mode of d e composition, g iving rise to a 3/2 f S order dependence upon hy d.roperoxide concent :r8.tl on . Experimental activation e nergies for the decomposition were f ound to be between 29.5 kcsl./raole and 30.0 k cal./mole .• \,iith log A factors between 11 . 3 and 12.3. Product studies were conducted in R variety of solvents a s well as in the pr esence of a variety of free r adical initiators . Investigation of the kinetic ch a in length indicated a chain length of about fifty. A degenerat i ve chain branching mechanism 1s proposed which predicts the multi t ude of products which Rre observed e xperimentally as well as giving activation energies and log A factors si~il a r to those found experimentally .

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The effects of sample solvent composition and the injection volume, on the chromatographic peak profiles of two carbamate derivatives, methyl 2-benzimidazolecarbamate (MBC) and 3-butyl-2,4-dioxo[1,2-a]-s-triazinobenzimidazole (STB), were studied using reverse phase high performance liquid chromatograph. The study examined the effects of acetonitrile percentage in the sample solvent from 5 to 50%, effects of methanol percentage from 5 to 50%, effects of pH increase from 4.42 to 9.10, and effect of increasing buffer concentration from ° to 0.12M. The effects were studied at constant and increasing injection mass and at four injection volumes of 10, 50, 100 and 200 uL. The study demonstrated that the amount and the type of the organic solvents, the pH, and the buffer strength of the sample solution can have a pronounced effect on the peak heights, peak widths, and retention times of compounds analysed. MBC, which is capable of intramolecular hydrogen bonding and has no tendency to ionize, showed a predictable increase .in band broadening and a decrease in retention times at higher eluting strengths of the sample solvent. STB, which has a tendency to ionize or to strongly interact with the sample solvent, was influenced in various ways by the changes in ths sample solvent composition. The sample solvent effects became more pronounced as the injection volume increased and as the percentage of organic solvent in the sample solution became greater. The peak height increases for STB at increasing buffer concentrations became much more pronounced at higher analyte concentrations. It was shown that the widely accepted procedure of dissolving samples in the mobile phase does not yield the most efficient chromatograms. For that reason samples should be dissolved in the solutions with higher aqueous content than that of the mobile phase whenever possible. The results strongly recommend that all the samples and standards, regardless whether the standards are external or internal, be analysed at a constant sample composition and a constant injection volume.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Factors affecting the detennination of PAHs by capillary GC/MS were studied. The effect of the initial column temperature and the injection solvent on the peak areas and heights of sixteen PAHs, considered as priority pollutants, USillg crosslinked methyl silicone (DB!) and 5% diphenyl, 94% dimethyl, 1% vinyl polysiloxane (DBS) columns was examined. The possibility of using high boiling point alcohols especially butanol, pentanol, cyclopentanol, and hexanol as injection solvents was investigated. Studies were carried out to optimize the initial column temperature for each of the alcohols. It was found that the optimum initial column temperature is dependent on the solvent employed. The peak areas and heights of the PAHs are enhanced when the initial column temperature is 10-20 c above the boiling point of the solvent using DB5 column, and the same or 10 C above the boiling point of the solvent using DB1 column. Comparing the peak signals of the PAHs using the alcohols, p-xylene, n-octane, and nonane as injection solvents, hexanol gave the greatest peak areas and heights of the PAHs particularly the late-eluted peaks. The detection limits were at low pg levels, ranging from 6.0 pg for fluorene t9 83.6 pg for benzo(a)pyrene. The effect of the initial column temperature on the peak shape and the separation efficiency of the PARs was also studied using DB1 and DB5 columns. Fronting or splitting of the peaks was obseIVed at very low initial column temperature. When high initial column temperature was used, tailing of the peaks appeared. Great difference between DB! and.DB5 columns in the range of the initial column temperature in which symmetrical.peaks of PAHs can be obtained is observed. Wider ranges were shown using DB5 column. Resolution of the closely-eluted PAHs was also affected by the initial column temperature depending on the stationary phase employed. In the case of DB5, only the earlyeluted PAHs were affected; whereas, with DB1, all PAHs were affected. An analytical procedure utilizing solid phase extraction with bonded phase silica (C8) cartridges combined with GC/MS was developed to analyze PAHs in water as an alternative method to those based on the extraction with organic solvent. This simple procedure involved passing a 50 ml of spiked water sample through C8 bonded phase silica cartridges at 10 ml/min, dried by passing a gentle flow of nitrogen at 20 ml/min for 30 sec, and eluting the trapped PAHs with 500 Jll of p-xylene at 0.3 ml/min. The recoveries of PAHs were greater than 80%, with less than 10% relative standard deviations of nine determinations. No major contaminants were present that could interfere with the recognition of PAHs. It was also found that these bonded phase silica cartridges can be re-used for the extraction of PAHs from water.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The preparation of phenacyl and para-phenylphenacyl esters, the reactions of carboxylic acids, phenols, 2-nitropropane and alcohols with alkyl halides in the presence of fluoride anion are described. The reactions are thought to be accelerated by the formation of hydrogen bonds between the fluoride anion and the organic electron acceptor. The fluoride ,carboxylic acids, fluoride-phenols and fluoride-2-nitropropane are better reaction systems than the fluoride-alcohol. The source of the fluoride anion and the choice of solvents are also discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Hydrogen bond assisted alkylation of phenols is compared with the classical base assisted reactions. The influence of solvents on the fluoride assisted reactions is discussed,· with emphasis on the localization of hydrogen bond charge density. Polar aprotic solvents such as DMF favour a-alkylation, and nonpolar aprotic solvents such as toluene favourC-alkylation of phenol. For more reactive and soluble fluorides, such as tetrabu~ylammoniumfluoride, the polar aprotic solvent favours a-alkylation and nonpolar aprotic solvent favours fluorination. Freeze-dried potassium fluoride is a better catalytic agent in hydrogen bond assisted alkylation reactions of phenol than the oven-dried fluoride. The presence of water in the alkylation reactions reduces the expected yield drastically. The tolerance of the reaction to water has also been studied. The use ofa phase transfer catalyst such as tetrabutylammonium bromide in the alkylation reactions of phenol in the presence of potassium fluoride is very effective under anhydrous conditions. Sterically hindered phenols such as 2,6-ditertiarybutyl-4-methyl phenol could not be alkylated even by using the more reactive fluorides, such as tetrabutylammonium fluoride in either polar or nonpolar aprotic solvents. Attempts were also made to alkylate phenols in the presence of triphenylphosphine oxide.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Re~tes artd pJ~oducts of tllerma]. d,ecom.position of sec-butyl peroxide at 110 - 150°C i.n four solvents h,ave been determined. The d,ecompos i tion vJas sb.o\'\Tn to be tlnlmolecl.llar wi tho energies of activation in toluene, benzene, and cyclohexane of 36 .7-+ 1.0, 33.2 +- 1..0, 33.t~) +.. 1.0 I'(:cal/mol respectively. The activation energy of thermal decomposition for the d,et.1terated peroxide was found to be 37.2 4:- 1.0 KC8:1/1TIol in toluene. A.bo1J.t 70 - 80/~ ol~ tJJ.e' pl~od.1..1CtS could, be explained by kn01rJ11 reactions of free allcoxy raclicals J and very littJ...e, i.f allY, disPl"Opox~tiol'lation of tll10 sec-butoxy radica.ls in t116 solvent cage could be detected. The oth,er 20 - 30% of the peroxide yielded H2 and metb.:'ll etb..yl 1{etol1e. Tl1.e yield. o:f H2 "'lIas unafJ:'ected by the nature or the viscosity of the solvent, but H2 was not formed when s-t1U202 lrJaS phctolyzed. in tolttene at 35°C nor 'tl!Jrl.en the peroxide 1;'JaS tl1.ermally o..ecoJnposed. in the gas p11ase. ~pC-Dideutero-~-butYlperoxide was prepared and decomposed in toluene at 110 - 150°C. The yield of D2 was about ·•e1ne same 248 the yield. of I{2 from s-Bu202, bU.t th.e rate of decomposition (at 135°C) 1iJas only 1/1.55 as fast. Ivlecl1.anisms fOl') J:1ydrogen produ.ction are discussed, but none satisfactorily explains all the evidence.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Rates of H2 formation have been determined for the thermal decomposition of isopropyl peroxide at l30o-l50oC in toluene and methanol and at l400C in isopropyl alcohol and water. Product studies have been carried out at l400C in these solvents. The decomposition of isopropyl peroxide was shown to be unimolecular with energies of activation in toluene, and methanol of 39.1, 23.08 Kcal/mole respectively. It has been shown that the rates of H2 formation in decomposition of isopropyl peroxide are solvent dependent and that the ~ vs "'2';' values (parameters for solvent polarity) givesastraight line. Mechanisms for hydrogen production are discussed which satisfactorily explain the stabilization of the six-centered transition state by the solvent. One possibility is that of conformation stabilization by solvent and the other, a transition state with sufficient ionic character to be stabilized by a polar solvent. Rates of thermal decomposition of 1,2-dioxane in tert-butylbenzene at l40o-l70oC have been determined. The activation energy was found to be 33.4 Kcal/mole. This lower activation energy, compared to that for the decomposition of isopropyl peroxide in toluene (39.1 Kcal/mole) has been explained in terms of ring strain. Decomposition of 1,2 dioxane in MeOH does not follow a first order reaction. Several mechanisms have been suggested for the products observed for decomposition of 1;2-dioxane in toluene and methanol.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Factors involved in the determination of PAHs (16 priority PAHs as an example) and PCBs (10 PCB congeners, representing 10 isomeric groups) by capillary gas chromatography coupled with mass spectrometry (GC/MS, for PAHs) and electron capture detection (GC/ECD , for PCBs) were studied, with emphasis on the effect of solvent. Having various volatilities and different polarities, solvent studied included dichloromethane, acetonitrile, hexan e, cyclohexane, isooctane, octane, nonane, dodecane, benzene, toluene, p-xylene, o-xylene, and mesitylene. Temperatures of the capillary column, the injection port, the GC/MS interface, the flow rates of carrier gas and make-up gas, and the injection volume were optimized by one factor at a time method or simplex optimization method. Under the optimized conditions, both peak height and peak area of 16 PAHs, especially the late-eluting PAHs, were significantly enhanced (1 to 500 times) by using relatively higher boiling point solvents such as p-xylene and nonane, compared with commonly used solvents like benzene and isooctane. With the improved sensitivity, detection limits of between 4.4 pg for naphthalene and 30.8 pg for benzo[g,h,i]perylene were obtained when p-xylene was used as an injection solvent. Effect of solvent on peak shape and peak intensity were found to be greatly dependent on temperature parameters, especially the initial temperature of the capillary column. The relationship between initial temperature and shape of peaks from 16 PAHs and 10 PCBs were studied and compared when toluene, p-xylene, isooctane, and nonane were used as injection solvents. If a too low initial temperature was used, fronting or split of peaks was observed. On the other hand, peak tailing occurred at a too high initial column temperature. The optimum initial temperature, at which both peak fronting and tailing were avoided and symmetrical peaks were obtained, depended on both solvents and the stationary phase of the column used. On a methyl silicone column, the alkane solvents provided wider optimum ranges of initial temperature than aromatic solvents did, for achieving well-shaped symmetrical GC peaks. On a 5% diphenyl: 1% vinyl: 94% dimethyl polysiloxane column, when the aromatic solvents were used, the optimum initial temperature ranges for solutes to form symmetrical peaks were improved to a similar degree as those when the alkanes were used as injection solvents. A mechanism, based on the properties of and possible interactions among the analyte, the injection solvent, and the stationary phase of the capillary column, was proposed to explain these observations. The effect of initial temperature on peak height and peak area of the 16 PAHs and the 10 PCBs was also studied. The optimum initial temperature was found to be dependent on the physical properties of the solvent used and the amount of the solvent injected. Generally, from the boiling point of the solvent to 10 0C above its boiling point was an optimum range of initial temperature at which cthe highest peak height and peak area were obtained.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This project aimed to determine the protein prof i les and concent rat ion in honeys, ef fect of storage condi t ions on the protein content and the interact ion between proteins and polyphenols. Thi r teen honeys f rom di f ferent botanical or igins were analyzed for thei r protein prof i les using SDS-PAGE, protein concent rat ion and phenol ic content , using the Pierce Protein Assay and Fol in-Ciocal teau methods, respectively. Protein-polyphenol interact ions were analyzed by a combinat ion of the ext ract ion of honeys wi th solvents of di f ferent polar i t ies fol lowed by LCjMS analysis of the obtained f ract ions. Results demonst rated a di f ferent protein content in the tested honeys, wi th buckwheat honey possessing the highest protein concent rat ion. We have shown that the reduct ion of proteins dur ing honey storage was caused, partially, by the protein complexat ion wi th phenolics. The LCjMS analysis of the peak elut ing at retent ion t ime of 10 to 14 min demonst rated that these phenolics included f lavonoids such as Pinobanksin, Pinobanksin acetate, Apigenin, Kaemferol and Myricetin and also cinnamic acid.