6 resultados para Sodium-ions

em Brock University, Canada


Relevância:

20.00% 20.00%

Publicador:

Resumo:

All-electron partitioning of wave functions into products ^core^vai of core and valence parts in orbital space results in the loss of core-valence antisymmetry, uncorrelation of motion of core and valence electrons, and core-valence overlap. These effects are studied with the variational Monte Carlo method using appropriately designed wave functions for the first-row atoms and positive ions. It is shown that the loss of antisymmetry with respect to interchange of core and valence electrons is a dominant effect which increases rapidly through the row, while the effect of core-valence uncorrelation is generally smaller. Orthogonality of the core and valence parts partially substitutes the exclusion principle and is absolutely necessary for meaningful calculations with partitioned wave functions. Core-valence overlap may lead to nonsensical values of the total energy. It has been found that even relatively crude core-valence partitioned wave functions generally can estimate ionization potentials with better accuracy than that of the traditional, non-partitioned ones, provided that they achieve maximum separation (independence) of core and valence shells accompanied by high internal flexibility of ^core and Wvai- Our best core-valence partitioned wave function of that kind estimates the IP's with an accuracy comparable to the most accurate theoretical determinations in the literature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Analytical methods for the determination of trace amounts of germanium, tin and arsenic were established using hydride generation coupled with direct current plasma atomic emission spectrometry. A continuous gas flowing batch system for the hydride generation was investigated and was applied to the determination of germanium(Ge), tin(Sn), antimony(Sb) and lead(Pb) (Preliminary results suggest that it is also applicable to arsenic)As) ). With this system, the reproducibility of signals was improved and the determination was speeded up, compared with the conventional batch type hydride generation system. Each determination was complete within one minute. Interferences from a number of transition metal ions, especially from Pd(II), Pt(IV), Ni(II), Cu(II), Co(II), and Fe(II, III), have proven to be very serious under normal conditions, in the determination of germanium, tin, and arsenic. These interference effects were eliminated or significantly reduced in the presence of L-cystine or L-cysteine. Thus, a 10-1000 fold excess of Ni(II), Cu(II), Co(II), Fe(II), Pt(IV), Pd(II), etc. can be tolerated without interference, In the presence of L-cystine or L-cysteine, compared with absence of interference reducing agent. The methods for the determination of Ge, Sn, and As were examined by the analyses of standard reference materials. Interference effects from the sample matrix, for example, in transition metal-rich samples, copper, iron and steel, were eliminated by L-cystine (for As and Sn) and by LI cysteine (for Ge). The analysis of a number of standard reference materials gave excellent results of As and Sn contents in agreement with the certified values, showing there was no systematic interference. The detection limits for both germanium and tin were 20 pg ml- I . Preliminary studies were carried out for the determination of antimony and lead. Antimony was found to react with NaBH4, remaInIng from the previous determinations, giving an analytical signal. A reversed injection manner, i.e., injection of the NaBH4 solution prior to the analyte solution was used to avoid uncertainty caused by residual NaBH4 present and to ensure that an excess of NaB H4 was available. A solution of 0.4% L-cysteine was found to reduce the interference from selected transition metal ions, Co(II), Cu(II), Ni(II) and Pt(IV). Hydrochloric acid - hydrogen peroxide, nitric acid - ammonium persulphate, and potassium dichromate malic acid reaction systems for lead hydride generation were compared. The potassium dichromate - malic acid reaction medium proved to be the best with respect to reproducibility and minimal interference. Cu(II), Ni(II), and Fe(II) caused strong interference In lead determinations, which was not reduced by L-cysteine or Lcystine. Sodium citrate, ascorbic acid, dithizone, thiosemicarbazide and penicillamine reduced interferences to some extent. Further interference reduction studies were carried out uSIng a number of amino acids, glycine, alanine, valine, leucine and histidine, as possible interference reducing agents in the determination of germanium. From glycine, alanine, valine to leucine, the interference reduction effect in germanium determinations decreased. Histidine II was found to be very promising In the reduction of interference. In fact, histidine proved more efficient than L-cystine and L-cysteine In the reduction of interference from Ni(II) in the determination of germanium. Signal enhancement by easily ionized elements (EIEs), usually regarded as an interference effect in analysis by DCP-AES, was studied and successfully applied to advantage in improving the sensitivity and detection limit in the determination of As, Ge, Sn, Sb, and Pb. The effect of alkali and alkaline-earth elements on the determination of the above five hydride forming elements was studied. With the appropriate EIE, a signal enhancement of 40-115% was achieved. Linear calibration and good reproducibility were also obtained in the presence of EIEs. III

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The algebraic expressions for the anharmonic contributions to the Debye-Waller factor up to 0(A ) and 0 L% ) £ where ^ is the scattering wave-vector] have been derived in a form suitable for cubic metals with small ion cores where the interatomic potential extends to many neighbours. This has been achieved in terms of various wave-vector dependent tensors, following the work of Shukla and Taylor (1974) on the cubic anharmonic Helmholtz free energy. The contribution to the various wave-vector dependent tensors from the coulomb and the electron-ion terms in the interatomic metallic potential has been obtained by the Ewald procedure. All the restricted multiple whole B r i l l o u i n zone (B.Z.) sums are reduced to single whole B.Z. sums by using the plane wave representation of the delta function. These single whole B.Z. sums are further reduced to the •%?? portion of the B.Z. following Shukla and Wilk (1974) and Shukla and Taylor (1974). Numerical calculations have been performed for sodium where the Born-Mayer term in the interatomic potential has been neglected because i t is small £ Vosko (1964)3 • *n o^er to compare our calculated results with the experimental results of Dawton (1937), we have also calculated the r a t io of the intensities at different temperatures for the lowest five reflections (110), (200), (220), (310) and (400) . Our calculated quasi-harmonic results agree reasonably well with the experimental results at temperatures (T) of the order of the Debye temperature ( 0 ). For T » © ^ 9 our calculated anharmonic results are found to be in good agreement with the experimental results.The anomalous terms in the Debye-Waller factor are found not to be negligible for certain reflections even for T ^ ©^ . At temperature T yy Op 9 where the temperature is of the order of the melting temperature (Xm) » "the anomalous terms are found to be important almost for all the f i ve reflections.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two groups of rainbow trout were acclimated to 20 , 100 , and 18 o C. Plasma sodium, potassium, and chloride levels were determined for both. One group was employed in the estimation of branchial and renal (Na+-K+)-stimulated, (HC0 3-)-stimulated, and CMg++)-dependent ATPase activities, while the other was used in the measurement of carbonic anhydrase activity in the blood, gill and kidney. Assays were conducted using two incubation temperature schemes. One provided for incubation of all preparations at a common temperature of 2S oC, a value equivalent to the upper incipient lethal level for this species. In the other procedure the preparations were incubated at the appropriate acclimation temperature of the sampled fish. Trout were able to maintain plasma sodium and chloride levels essentially constant over the temperature range employed. The different incubation temperature protocols produced different levels of activity, and, in some cases, contrary trends with respect to acclimation temperature. This information was discussed in relation to previous work on gill and kidney. The standing-gradient flow hypothesis was discussed with reference to the structure of the chloride cell, known thermallyinduced changes in ion uptake, and the enzyme activities obtained in this study. Modifications of the model of gill lon uptake suggested by Maetz (1971) were proposed; high and low temperature models resulting. In short, ion transport at the gill at low temperatures appears to involve sodium and chloride 2 uptake by heteroionic exchange mechanisms working in association w.lth ca.rbonlc anhydrase. G.l ll ( Na + -K + ) -ATPase and erythrocyte carbonic anhydrase seem to provide the supplemental uptake required at higher temperatures. It appears that the kidney is prominent in ion transport at low temperatures while the gill is more important at high temperatures. 3 Linear regression analyses involving weight, plasma ion levels, and enzyme activities indicated several trends, the most significant being the interrelationship observed between plasma sodium and chloride. This, and other data obtained in the study was considered in light of the theory that a link exists between plasma sodium and chloride regulatory mechanisms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The primary objective of this investigation was that of providing a comprehensive tissue-by-tissue assessment of water-electrolyte status in thermally-acclimated rainbow trout, Salmo gairdneri. To this end levels of water and the major ions, sodium, chloride and potassium were evaluated in the plasma, at three skeletal muscle sites, and in cardiac muscle, liver, spleen, gut and brain of animals acclimated to 2°, 10° and 18°C. The occurrence of possible seasonal variations in water-electrolyte balance was evaluated by sampling sununer and late fall-early winter populations of trout. On the basis of values for water and electrolyte content, estimates of extracellular and cellular phase volumes, cellular electrolyte concentrations and Nernst equilibrium potentials were made. Since accurate assessment of the extracellular phase volume is critical in the estimation of cellular electrolyte concentrations and parameters based on assumed cellular ion levels, [14 C]-polyethylene glycol-4000, which is assumed to be confined to the extracellular space, was employed to provide comparisons with various ion-defined spaces (H20~~s, H20~~/K and H20~~s). Subsequently, the ion-defined space yielding the most realistic estimate of extracellular phase volume for each tissue was used in cellular electrolyte calculations. Water and electrolyte content and distribution varied with temperature. Tissues, such as liver, spleen and brain appeared to be the most thermosensitive, whereas skeletal and cardiac muscle and gut tissue were less influenced. 'Summer' series trout appeared to be more capable of maintaining their water- electrolyte balance than the ~fall-winter' series animals. i The data are discussed in terms of their possible effect on maintenance of appropriate cellular metabolic and electrophysiological functions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A double-blinded, placebo controlled, cross-over design was used to investigate sodium citrate dihydrate (Na-CIT) supplementation improve 200m swimming performance. Ten well-trained, male swimmers (14.9 ± 0.4y; 63.5 ± 4kg) performed four 200m time trials: acute (ACU) supplementation (0.5g/kg), acute placebo (PLC-A), chronic (CHR) (0.1g/kg for 3 days and 0.3g/kg on the 4th day pre-trial), and chronic placebo (PLC-C). Na-CIT was administered 120min pre-trial in solution with 500mL of flavored water; placebo was flavored water. Blood lactate, base excess (BE), bicarbonate, pH, and PCO2 were analyzed at basal, 100min post-ingestion, and 3min post-trial via finger prick. Time, lactate, and rate of perceived exertion were not different between trials. BE and bicarbonate were significantly higher for the ACU and CHR trials compared to placebo. “Responders” improved by 1.03% (P=0.043) and attained significantly higher post-trial lactate concentrations in the ACU versus PLC-A trials and compared to non-responders in the ACU and CHR trials.