2 resultados para Schoppe, Kaspar, 1576-1649.
em Brock University, Canada
Resumo:
Growth rates of etiolated Avena sativa coleoptiles in pH 7.0 buffered medium are stimulated in a synergistic manner by IAA and 320 ~l/l carbon dioxide. The suggestion that carbon dioxide stimulated growth involves dark fixation is supported by the ability of 1 mM malate to replace carbon dioxide, with neither factor able to stimulate growth in the presence of the other (Bown, Dymock and Aung, 1974). The regulation of Avena coleoptile growth by ethylene has been investigated in the light of this data and the well documented antagonism between carbon dioxide and ethylene in the regulation of developmental processes. The influence of various permutations of ethylene, IAA, carbon dioxide and malate on the rates of growth, l4c-bicarbonate incorporation, l4C-bicarbonate fixation, and malate decarboxylation have been investigated. In the presence of 320 ~l/l carbon dioxide, 10.8 ~l/l ethylene inhibited growth both in the absence and presence of 20 ~M IAA with inhibition times, of 8-10 and 12-13 minutes respectively. In contrast ethylene inhibition of growth was not significant in the absence of growth stimulation by CO2 or 1 mM malate, and the normal growth increases in response to CO2 and malate were blocked by the simultaneous application of ethylene. The rates of incorporation and dark fixation of l4C-bicerbonate were not measurably. influenced by ethylene, IAA or malate, either prior to or during the changes in growth ,ates induced by these agents. The data does not support the hypothesis that ethylene inhibition of growth results from an inhibition of dark fixation, but suggests that ethylene may inhibit a process which is subsequent to fixation.
Resumo:
Microwave digestions of mercury in Standards Reference Material (SRM) coal samples with nitric acid and hydrogen peroxide in quartz vessels were compared with Teflon® vessel digestion by using flow injection cold vapor atomic absorption spectrometry. Teflon® vessels gave poor reproducibiUty and tended to deliver high values, while the digestion results from quartz vessel show good agreement with certificate values and better standard deviations. Trace level elements (Ag, Ba, Cd, Cr, Co, Cu, Fe, Mg, Mn, Mo, Pb, Sn, Ti, V and Zn) in used oil and residual oil samples were determined by inductively coupled plasma-optical emission spectrometry. Different microwave digestion programs were developed for each sample and most of the results are in good agreement with certified values. The disagreement with values for Ag was due to the precipitation of Ag in sample; while Sn, V and Zn values had good recoveries from the spike test, which suggests that these certified values might need to be reconsidered. Gold, silver, copper, cadmium, cobalt, nickel and zinc were determined by continuous hydride generation inductively coupled plasma-optical emission spectrometry. The performance of two sample introduction systems: MSIS™ and gas-liquid separator were compared. Under the respective optimum conditions, MSIS^"^ showed better sensitivity and lower detection limits for Ag, Cd, Cu, Co and similar values for Au, Ni and Zn to those for the gas-liquid separator.