2 resultados para Priority areas

em Brock University, Canada


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sediment relationships observed during geological mapping in southeastern Ontario indicate a relatively simple deglaciation history for the area during late Wisconsin time. The ice from the north (part of the Lake Simcoe lobe) and the Lake Ontario ice lobe, which were coalesced during most of late Wisconsin time, initially separated along the crest of the Oak Ridges Moraine. Available data indicate that the Oak Ridges Moraine is composed primarily of sediments pre-late Wisconsin in age capped by late Wisconsin till and interlobate deposits. Retreat of the northern ice was relatively steady and resulted in the deposition of the Dummer Moraines, a facies of the drumlinized till to the south. Retreat of the Lake Ontario ice lobe into the Lake Ontario basin was interrupted by a re-advance which covered the southeastern half of the map area. The northern ice had already retreated from the area by this time. The Lake Ontario lobe was fed through the St. Lawrence Valley, indicating that the Ottawa Valley was ice filled at this time. High level glacial lakes fronted the ice during deglaciation. These waters quickly fell to low levels as the ice retreated from the St. Lawrence Valley, opening lower outlets.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Factors affecting the detennination of PAHs by capillary GC/MS were studied. The effect of the initial column temperature and the injection solvent on the peak areas and heights of sixteen PAHs, considered as priority pollutants, USillg crosslinked methyl silicone (DB!) and 5% diphenyl, 94% dimethyl, 1% vinyl polysiloxane (DBS) columns was examined. The possibility of using high boiling point alcohols especially butanol, pentanol, cyclopentanol, and hexanol as injection solvents was investigated. Studies were carried out to optimize the initial column temperature for each of the alcohols. It was found that the optimum initial column temperature is dependent on the solvent employed. The peak areas and heights of the PAHs are enhanced when the initial column temperature is 10-20 c above the boiling point of the solvent using DB5 column, and the same or 10 C above the boiling point of the solvent using DB1 column. Comparing the peak signals of the PAHs using the alcohols, p-xylene, n-octane, and nonane as injection solvents, hexanol gave the greatest peak areas and heights of the PAHs particularly the late-eluted peaks. The detection limits were at low pg levels, ranging from 6.0 pg for fluorene t9 83.6 pg for benzo(a)pyrene. The effect of the initial column temperature on the peak shape and the separation efficiency of the PARs was also studied using DB1 and DB5 columns. Fronting or splitting of the peaks was obseIVed at very low initial column temperature. When high initial column temperature was used, tailing of the peaks appeared. Great difference between DB! and.DB5 columns in the range of the initial column temperature in which symmetrical.peaks of PAHs can be obtained is observed. Wider ranges were shown using DB5 column. Resolution of the closely-eluted PAHs was also affected by the initial column temperature depending on the stationary phase employed. In the case of DB5, only the earlyeluted PAHs were affected; whereas, with DB1, all PAHs were affected. An analytical procedure utilizing solid phase extraction with bonded phase silica (C8) cartridges combined with GC/MS was developed to analyze PAHs in water as an alternative method to those based on the extraction with organic solvent. This simple procedure involved passing a 50 ml of spiked water sample through C8 bonded phase silica cartridges at 10 ml/min, dried by passing a gentle flow of nitrogen at 20 ml/min for 30 sec, and eluting the trapped PAHs with 500 Jll of p-xylene at 0.3 ml/min. The recoveries of PAHs were greater than 80%, with less than 10% relative standard deviations of nine determinations. No major contaminants were present that could interfere with the recognition of PAHs. It was also found that these bonded phase silica cartridges can be re-used for the extraction of PAHs from water.