2 resultados para PSF
em Brock University, Canada
Resumo:
The ability of the cardiovascular system to quickly and efficiently adapt to an orthostatic stress is vital for the human body to function on earth. The way in which the various aspects of the cardiovascular system work together to counteract an orthostatic stress has been previously quantified in the adult population. However, there are still many unknowns surrounding the topic of how the cardiovascular system functions to cope with this same stress in children. The purpose of this study was to describe the cardiovascular hemodynamic adaptations to various levels of orthostatic stress induced using a lower body negative pressure (LBNP) chamber in pre-pubertal boys. A secondary purpose was to determine indices of baroreceptor sensitivity (BRS) at both rest and during low levels of LBNP in this same pediatric sample. Finally, this study aimed to compare the relative responses to LBNP between the children and adults. To complete the study 20 healthy pre-pubertal boys and adult males (9.3 ± 1.1 and 23 ± 1.8 years of age respectively) were recruited and randomly exposed to three levels of LBNP (15, 20 and 25 mmHg). At rest and during the application of the LBNP heart rate (HR), manual and bcat-by-beat systolic (SBP), diastolic (DBP) and mean arterial blood pressure (MAP) were monitored continuously. Aortic diameter was measured at rest and peak aortic blood velocity (PV) was recorded continuously for at least I minute during each baseline and LBNP condition. From the raw data HR, stroke volume (SV), cardiac output (Q), total peripheral resistance (TPR), low frequency baroreceptor sensitivity (LF BRS), high frequency baroreceptor sensitivity (HF BRS) and LFIIIF ratio were calculated. At rest, llR wa'i higher and SBP, SV, Q and LF/HF ratio were lower in the children compared to the adult males (pgJ.05). In response to the increasing LEN!> IIR and TPR increased, and LF BRS. SV and Q decreased in the adult group (pSf).05). while the same levels of LBNP caused an increase in TPR and a decrease in SBP, SV and Q in the children (pSf).05). Although not significant, the LF/HF ratio in the adult group showed an increasing trend in response to increased negative pressure (p=O.088). As for resting BRS, there were no significant differences in LF or HF BRS between the children and the adults despite a tendency for both measures to be 18% lower in the children. Also the LF/HF ratio was almost significantly greater in the adults compared to the children (p=O.057). In addition, a comparison between the relative adult and child responses to LBNP yielded no significant group by level interactions. This result should be taken with caution though, as the low sample size and high measurement variability generated very low statistical power for this analysis. In conclusion, the results of this study suggest that the hemodynamic adaptations to an orthostatic stress were less pronounced in the prepubertal males, most likely due to an underdeveloped autonomic system. These results need to be strengthened by further research before any implications can be derived for health care purposes.
Resumo:
Confocal and two-photon microcopy have become essential tools in biological research and today many investigations are not possible without their help. The valuable advantage that these two techniques offer is the ability of optical sectioning. Optical sectioning makes it possible to obtain 3D visuahzation of the structiu-es, and hence, valuable information of the structural relationships, the geometrical, and the morphological aspects of the specimen. The achievable lateral and axial resolutions by confocal and two-photon microscopy, similar to other optical imaging systems, are both defined by the diffraction theorem. Any aberration and imperfection present during the imaging results in broadening of the calculated theoretical resolution, blurring, geometrical distortions in the acquired images that interfere with the analysis of the structures, and lower the collected fluorescence from the specimen. The aberrations may have different causes and they can be classified by their sources such as specimen-induced aberrations, optics-induced aberrations, illumination aberrations, and misalignment aberrations. This thesis presents an investigation and study of image enhancement. The goal of this thesis was approached in two different directions. Initially, we investigated the sources of the imperfections. We propose methods to eliminate or minimize aberrations introduced during the image acquisition by optimizing the acquisition conditions. The impact on the resolution as a result of using a coverslip the thickness of which is mismatched with the one that the objective lens is designed for was shown and a novel technique was introduced in order to define the proper value on the correction collar of the lens. The amoimt of spherical aberration with regard to t he numerical aperture of the objective lens was investigated and it was shown that, based on the purpose of our imaging tasks, different numerical apertures must be used. The deformed beam cross section of the single-photon excitation source was corrected and the enhancement of the resolution and image quaUty was shown. Furthermore, the dependency of the scattered light on the excitation wavelength was shown empirically. In the second part, we continued the study of the image enhancement process by deconvolution techniques. Although deconvolution algorithms are used widely to improve the quality of the images, how well a deconvolution algorithm responds highly depends on the point spread function (PSF) of the imaging system applied to the algorithm and the level of its accuracy. We investigated approaches that can be done in order to obtain more precise PSF. Novel methods to improve the pattern of the PSF and reduce the noise are proposed. Furthermore, multiple soiu'ces to extract the PSFs of the imaging system are introduced and the empirical deconvolution results by using each of these PSFs are compared together. The results confirm that a greater improvement attained by applying the in situ PSF during the deconvolution process.