5 resultados para Needle biopsy
em Brock University, Canada
Resumo:
Polarized reflectance measurements of the quasi I-D charge-transfer salt (TMTSFh CI04 were carried out using a Martin-Puplett-type polarizing interferometer and a 3He refrigerator cryostat, at several temperatures between 0.45 K and 26 K, in the far infrared, in the 10 to 70 cm- 1 frequency range. Bis-tetramethyl-tetraselena-fulvalene perchlorate crystals, grown electrochemically and supplied by K. Behnia, of dimensions 2 to 4 by 0.4 by 0.2 mm, were assembled on a flat surface to form a mosaic of 1.5 by 3 mm. The needle shaped crystals were positioned parallel to each other along their long axis, which is the stacking direction of the planar TMTSF cations, exposing the ab plane face (parallel to which the sheets of CI04 anions are positioned). Reflectance measurements were performed with radiation polarized along the stacking direction in the sample. Measurements were carried out following either a fast (15-20 K per minute) or slow (0.1 K per minute) cooling of the sample. Slow cooling permits the anions to order near 24 K, and the sample is expected to be superconducting below 1.2 K, while fast cooling yields an insulating state at low temperatures. Upon the slow cooling the reflectance shows dependence with temperature and exhibits the 28 cm- 1 feature reported previously [1]. Thermoreflectance for both the 'slow' and 'fast' cooling of the sample calculated relative to the 26 K reflectance data indicates that the reflectance is temperature dependent, for the slow cooling case only. A low frequency edge in the absolute reflectance is assigned an electronic origin given its strong temperature dependence in the relaxed state. We attribute the peak in the absolute reflectance near 30 cm-1 to a phonon coupled to the electronic background. Both the low frequency edge and the 30 cm-1 feature are noted te shift towards higher frequcncy, upon cntering the superconducting state, by an amount of the order of the expected superconducting energy gap. Kramers-Kronig analysis was carried out to determine the optical conductivity for the slowly cooled sample from the measured reflectance. In order to do so the low frequency data was extrapolated to zero frequency using a Hagen-Ru bens behaviour, and the high frequency data was extended with the data of Cao et al. [2], and Kikuchi et al. [3]. The real part of the optical conductivity exhibits an asymmetric peak at 35 cm-1, and its background at lower frequencies seems to be losing spectral weight with lowering of the temperature, leading us to presume that a narrow peak is forming at even lower frequencies.
Resumo:
In 2003, prostate cancer (PCa) is estimated to be the most commonly diagnosed cancer and third leading cause of cancer death in Canada. During PCa population screening, approximately 25% of patients with a normal digital rectal examination (DRE) and intermediate serum prostate specific antigen (PSA) level have PCa. Since all patients typically undergo biopsy, it is expected that approximately 75% of these procedures are unnecessary. The purpose of this study was to compare the degree of efficacy of clinical tests and algorithms in stage II screening for PCa while preventing unnecessary biopsies from occurring. The sample consisted of 201 consecutive men who were suspected of PCa based on the results of a DRE and serum PSA. These men were referred for venipuncture and transrectal ultrasound (TRUS). Clinical tests included TRUS, agespecific reference range PSA (Age-PSA), prostate specific antigen density (PSAD), and free-to-total prostate specific antigen ratio (%fPSA). Clinical results were evaluated individually and within algorithms. Cutoffs of 0.12 and 0.15 ng/ml/cc were employed for PSAD. Cutoffs that would provide a minimum sensitivity of 0.90 and 0.95, respectively were utilized for %fPSA. Statistical analysis included ROC curve analysis, calculated sensitivity (Sens), specificity (Spec), and positive likelihood ratio (LR), with corresponding confidence intervals (Cl). The %fPSA, at a 23% cutoff ({ Sens=0.92; CI, 0.06}, {Spec=0.4l; CI, 0.09}, {LR=1.56; CI, O.ll}), proved to be the most efficacious independent clinical test. The combination of PSAD (cutoff 0.15 ng/ml/cc) and %fPSA (cutoff 23%) ({Sens=0.93; CI, 0.06}, {Spec=0.38; CI, 0.08}, {LR=1.50; CI, 0.10}) was the most efficacious clinical algorithm. This study advocates the use of %fPSA at a cutoff of 23% when screening patients with an intermediate serum PSA and benign DRE.
Resumo:
With repeated activity, force production, rate of force production, and relaxation time are impaired. These are characteristics ofa fatigued muscle (Vandenboom, 2004). However, brief bouts of near maximal to maximal activity results in the increased ability of the muscle to generate force, termed post activation potentiation (P AP)(V andervoort et aI., 1983). The purpose of the present study was to characterize motor unit firing rate (MUFR) in the unfatigued, potentiated tibialis anterior (TA). Using a quadrifilar needle electrode, MUFR was measured during a 5s 50% MVC in which the TA was either potentiated or unpotentiated; monopolar electrodes measured surface parameters. A lOs MVC was used to potentiate the muscle. Firing rate decreased significantly from 20.15±2.9Opps to 18.27±2.99pps, while mean power frequency decreased significantly from 60. 13±7.75 Hz to 53.62±8.56 Hz. No change in root mean square (RMS) was observed. Therefore, in the present study, MUFR decreases in response to a potentiated TA.
Resumo:
Globally, Prostate cancer (PCa) is the most frequently occurring non-cutaneous cancer, and is the second highest cause of cancer mortality in men. Serum prostate specific antigen (PSA) has been the standard in PCa screening since its approval by the American Food & Drug Administration (FDA) in 1994. Currently, PSA is used as an indicator for PCa - patients with a serum PSA level above 4ng/mL will often undergo prostate biopsy to confirm cancer. Unfortunately fewer than similar to 30% of these men will biopsy positive for cancer, meaning that the majority of men undergo invasive biopsy with little benefit. Despite PSA's notoriously poor specificity (33%), there is still a significant lack of credible alternatives. Therefore an ideal biomarker that can specifically detect PCa at an early stage is urgently required. The aim of this study was to investigate the potential of using deregulation of urinary proteins in order to detect Prostate Cancer (PCa) among Benign Prostatic Hyperplasia (BPH). To identify the protein signatures specific for PCa, protein expression profiling of 8 PCa patients, 12 BPH patients and 10 healthy males was carried out using LC-MS/MS. This was followed by validating relative expression levels of proteins present in urine among all the patients using quantitative real time-PCR. This was followed by validating relative expression levels of proteins present in urine among all the patients using quantitative real time-PCR. This approach revealed that significant the down-regulation of Fibronectin and TP53INP2 was a characteristic event among PCa patients. Fibronectin mRNA down-regulation, was identified as offering improved specificity (50%) over PSA, albeit with a slightly lower although still acceptable sensitivity (75%) for detecting PCa. As for TP53INP2 on the other hand, its down-regulation was moderately sensitive (75%), identifying many patients with PCa, but was entirely non-specific (7%), designating many of the benign samples as malignant and being unable to accurately identify more than one negative.
Resumo:
Brass Surveying Compass with a 6 1/2 inch diameter silvered brass dial signed E. and G.W. Blunt of New York. There is a fleur-de-lis at the north point and the outer needle ring is engraved 0-90 in four quadrants. There is an engraved central pattern, blue steel hand and brass lifter, shaped limbs and a brass dial cover. This belonged to Samuel DeVeaux Woodruff who was a Civil Engineer. It also belonged to R.D.W. Band who was also a Civil Engineer. Also, One 13 cm. brass spindle taper for the surveying compass, n.d