5 resultados para Least-squares method

em Brock University, Canada


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simple, low-cost concentric capillary nebulizer (CCN) was developed and evaluated for ICP spectrometry. The CCN could be operated at sample uptake rates of 0.050-1.00 ml min'^ and under oscillating and non-oscillating conditions. Aerosol characteristics for the CCN were studied using a laser Fraunhofter diffraction analyzer. Solvent transport efficiencies and transport rates, detection limits, and short- and long-term stabilities were evaluated for the CCN with a modified cyclonic spray chamber at different sample uptake rates. The Mg II (280.2nm)/l\/lg 1(285.2nm) ratio was used for matrix effect studies. Results were compared to those with conventional nebulizers, a cross-flow nebulizer with a Scott-type spray chamber, a GemCone nebulizer with a cyclonic spray chamber, and a Meinhard TR-30-K3 concentric nebulizer with a cyclonic spray chamber. Transport efficiencies of up to 57% were obtained for the CCN. For the elements tested, short- and long-term precisions and detection limits obtained with the CCN at 0.050-0.500 ml min'^ are similar to, or better than, those obtained on the same instrument using the conventional nebulizers (at 1.0 ml min'^). The depressive and enhancement effects of easily ionizable element Na, sulfuric acid, and dodecylamine surfactant on analyte signals with the CCN are similar to, or better than, those obtained with the conventional nebulizers. However, capillary clog was observed when the sample solution with high dissolved solids was nebulized for more than 40 min. The effects of data acquisition and data processing on detection limits were studied using inductively coupled plasma-atomic emission spectrometry. The study examined the effects of different detection limit approaches, the effects of data integration modes, the effects of regression modes, the effects of the standard concentration range and the number of standards, the effects of sample uptake rate, and the effect of Integration time. All the experiments followed the same protocols. Three detection limit approaches were examined, lUPAC method, the residual standard deviation (RSD), and the signal-to-background ratio and relative standard deviation of the background (SBR-RSDB). The study demonstrated that the different approaches, the integration modes, the regression methods, and the sample uptake rates can have an effect on detection limits. The study also showed that the different approaches give different detection limits and some methods (for example, RSD) are susceptible to the quality of calibration curves. Multicomponents spectral fitting (MSF) gave the best results among these three integration modes, peak height, peak area, and MSF. Weighted least squares method showed the ability to obtain better quality calibration curves. Although an effect of the number of standards on detection limits was not observed, multiple standards are recommended because they provide more reliable calibration curves. An increase of sample uptake rate and integration time could improve detection limits. However, an improvement with increased integration time on detection limits was not observed because the auto integration mode was used.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Emerging markets have received wide attention from investors around the globe because of their return potential and risk diversification. This research examines the selection and timing performance of Canadian mutual funds which invest in fixed-income and equity securities in emerging markets. We use (un)conditional two- and five-factor benchmark models that accommodate the dynamics of returns in emerging markets. We also adopt the cross-sectional bootstrap methodology to distinguish between ‘skill’ and ‘luck’ for individual funds. All the tests are conducted using a comprehensive data set of bond and equity emerging funds over the period of 1989-2011. The risk-adjusted measures of performance are estimated using the least squares method with the Newey-West adjustment for standard errors that are robust to conditional heteroskedasticity and autocorrelation. The performance statistics of the emerging funds before (after) management-related costs are insignificantly positive (significantly negative). They are sensitive to the chosen benchmark model and conditional information improves selection performance. The timing statistics are largely insignificant throughout the sample period and are not sensitive to the benchmark model. Evidence of timing and selecting abilities is obtained in a small number of funds which is not sensitive to the fees structure. We also find evidence that a majority of individual funds provide zero (very few provide positive) abnormal return before fees and a significantly negative return after fees. At the negative end of the tail of performance distribution, our resampling tests fail to reject the role of bad luck in the poor performance of funds and we conclude that most of them are merely ‘unlucky’.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The x-ray crystal structure of thiamine hydroiodide,C1ZH18N40S12' has been determined. The unit cell parameters are a = 13.84 ± 0.03, o b = 7.44 ± 0.01, c = 20.24 ± 0.02 A, 8 = 120.52 ± 0.07°, space group P2/c, z = 4. A total of 1445 reflections having ,2 > 2o(F2), 26 < 40° were collected on a Picker four-circle diffractometer with MoKa radiation by the 26 scan technique. The structure was solved by the heavy atom method. The iodine and sulphur atoms were refined anisotropically; only the positional parameters were refined for the hydrogen atoms. Successive least squares cycles yielded an unweighted R factor of 0.054. The site of protonation of the pyrimidine ring is the nitrogen opposite the amino group. The overall structure conforms very closely to the structures of other related thiamine compounds. The bonding surrounding the iodine atoms is distorted tetrahedral. The iodine atoms make several contacts with surrounding atoms most of them at or near the van der Waal's distances A thiaminium tetrachlorocobaltate salt was produced whose molecular and crystal structure was j~dged to be isomorphous to thiaminium tetrachlorocadmate.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The 3700 A - 3000 A absorption spectra of CH3CHO and its isotopic compounds such as CH3CDO, CD3CHO and CD3CDO were studied in the gas phase at room temperature and low temperatures. The low resolution spectra of the compounds were recorded by a 1.5 m Baush and Lomb grating spectrograph. The high resolution spectra were recorded by a Ebert spectrograph with the Echelle grating and the holographic grating separately. The multiple reflection cells were used to achieve the long path length. The pressure-path length used for the absorption spectrum of CH 3CHO was up to 100 mm Hg )( 91 . 43mo The emission spectrum and the excitation spectrum of CH3CHO were also recorded in this research. The calculated satellite band patterns \vhich were ob-tailied by the method of Lewis were used to compare with the observed near UV absorption spectrum of acetaldehyde. These calculated satellite band patterns belonged to two cases: namely, the barriers-in-phase case and the barriers- out-of-phase case. Each of the calculated patterns corresponded to a stable conformation of acetaldehyde in the excited state . The comparisons showed that the patterns in the observed absorption spectra corresponded to the H-H eclipsed conformations of acetaldehyde in the excited state . The least squares fitting analysis showed that the barrier heights in the excited state were higher than in the ground state. Finally, the isotopic shifts for the isotopic compounds of acetaldehyde were compared to the compounds with the similar deuterium substitution.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Digital Terrain Models (DTMs) are important in geology and geomorphology, since elevation data contains a lot of information pertaining to geomorphological processes that influence the topography. The first derivative of topography is attitude; the second is curvature. GIS tools were developed for derivation of strike, dip, curvature and curvature orientation from Digital Elevation Models (DEMs). A method for displaying both strike and dip simultaneously as colour-coded visualization (AVA) was implemented. A plug-in for calculating strike and dip via Least Squares Regression was created first using VB.NET. Further research produced a more computationally efficient solution, convolution filtering, which was implemented as Python scripts. These scripts were also used for calculation of curvature and curvature orientation. The application of these tools was demonstrated by performing morphometric studies on datasets from Earth and Mars. The tools show promise, however more work is needed to explore their full potential and possible uses.