7 resultados para Injection pain

em Brock University, Canada


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A flow injection hydride generation direct current plasma atomic emission spectrometric (FI-HG-DCP-AES) method was developed for the determination of lead at ng.ml-l level. Potassium ferricyanide (K3Fe(CN)6) was used along with sodium tetrahydroborate(III) (NaBH4) to produce plumbane (PbH4) in an acid medium. The design of a gas-liquid separator (hydride generator) was tested and the parameters of the flow injection system were optimized to achieve a good detection limit and sample throughput. The technique developed gave a detection limit of 0.7 ng.ml-l(3ob). The precision at 20 ng.ml"* level was 1.6 % RSD with 1 1 measurements (n=l 1). Volume of sample loop was 500 |J.l. A sample throughput of 120 h"^ was achieved. The transition elements, Fe(II), FeOH), Cd(n), Co(II), Mn(n), Ni(II) and Zn(n) do not interfere in this method but 1 mg,l'l Cu(II) will suppress 50 % of the signal from a sample containing 20 ng.ml'l Pb. This method was successfully applied to determine lead in a calcium carbonate (CaC03) matrix of banded coral skeletons from Si-Chang Island in Thailand.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This research provided relevant data to support pain research literature that finds nurses do not have the knowledge base that they require to sufficiently provide effective pain management. The data demonstrated that nurses have mixed attitudes toward pain. These two findings have been observed in the literature for more than 20 years, but were important results for the hospitals and the nurses involved in the study. The purposes of this study were to identify the level of knowledge and attitudes in a sample of nurses fi-om the surgical and medical units in three hospitals, and determine whether a difference between these two groups existed. The institutional resources to support pain relief practices provided by each hospital were also documented. Data were collected using a convenience sample from the medical and surgical units of three hospitals. Ofthe 1 13 nurses who volunteered to participate, 78 worked in surgical units and 35 worked in medical units. Demographic data were collected about the participants. The established instruments used to obtain data about knowledge and attitude included: (a) Nurses Knowledge of Pain Issues Survey, (b)Attitude to Pain Control Scale, and (c) Andrew and Robert Vignette. Data collected were quantitative along with two open-ended questions for a rich, qualitative section. Inadequate knowledge and outdated attitudes were very evident in the responses. Data from the open-ended questions described how nurses assessed pain and the most conmion problems caring for patients in pain. Nursing practice implications for these hospitals involve initiating a process to develop an educational pain program for nurses throughout the hospital. Utilizing findings from other studies, the program should have an interdisciplinary approach to the planning, implementation, evaluation, and ongoing support. This study supports the belief that inadequate pain management has been attributed to many factors, most importantly to a lack of knowledge. Pain is a costly, unnecessary complication for the patient as well as the hospital. It follows then, that it is in the best interest of all involved to implement an educational pain program in order to influence practice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effects of sample solvent composition and the injection volume, on the chromatographic peak profiles of two carbamate derivatives, methyl 2-benzimidazolecarbamate (MBC) and 3-butyl-2,4-dioxo[1,2-a]-s-triazinobenzimidazole (STB), were studied using reverse phase high performance liquid chromatograph. The study examined the effects of acetonitrile percentage in the sample solvent from 5 to 50%, effects of methanol percentage from 5 to 50%, effects of pH increase from 4.42 to 9.10, and effect of increasing buffer concentration from ° to 0.12M. The effects were studied at constant and increasing injection mass and at four injection volumes of 10, 50, 100 and 200 uL. The study demonstrated that the amount and the type of the organic solvents, the pH, and the buffer strength of the sample solution can have a pronounced effect on the peak heights, peak widths, and retention times of compounds analysed. MBC, which is capable of intramolecular hydrogen bonding and has no tendency to ionize, showed a predictable increase .in band broadening and a decrease in retention times at higher eluting strengths of the sample solvent. STB, which has a tendency to ionize or to strongly interact with the sample solvent, was influenced in various ways by the changes in ths sample solvent composition. The sample solvent effects became more pronounced as the injection volume increased and as the percentage of organic solvent in the sample solution became greater. The peak height increases for STB at increasing buffer concentrations became much more pronounced at higher analyte concentrations. It was shown that the widely accepted procedure of dissolving samples in the mobile phase does not yield the most efficient chromatograms. For that reason samples should be dissolved in the solutions with higher aqueous content than that of the mobile phase whenever possible. The results strongly recommend that all the samples and standards, regardless whether the standards are external or internal, be analysed at a constant sample composition and a constant injection volume.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Flow injection analysis (FIA) was applied to the determination of both chloride ion and mercury in water. Conventional FIA was employed for the chloride study. Investigations of the Fe3 +/Hg(SCN)2/CI-,450 nm spectrophotometric system for chloride determination led to the discovery of an absorbance in the 250-260 nm region when Hg(SCN)2 and CI- are combined in solution, in the absence of iron(III). Employing an in-house FIA system, absorbance observed at 254 nm exhibited a linear relation from essentially 0 - 2000 Jlg ml- 1 injected chloride. This linear range spanning three orders of magnitude is superior to the Fe3+/Hg(SCN)2/CI- system currently employed by laboratories worldwide. The detection limit obtainable with the proposed method was determin~d to be 0.16 Jlg ml- 1 and the relative standard deviation was determined to be 3.5 % over the concentration range of 0-200 Jig ml- 1. Other halogen ions were found to interfere with chloride determination at 254 nm whereas cations did not interfere. This system was successfully applied to the determination of chloride ion in laboratory water. Sequential injection (SI)-FIA was employed for mercury determination in water with the PSA Galahad mercury amalgamation, and Merlin mercury fluorescence detection systems. Initial mercury in air determinations involved injections of mercury saturated air directly into the Galahad whereas mercury in water determinations involved solution delivery via peristaltic pump to a gas/liquid separator, after reduction by stannous chloride. A series of changes were made to the internal hardware and valving systems of the Galahad mercury preconcentrator. Sequential injection solution delivery replaced the continuous peristaltic pump system and computer control was implemented to control and integrate all aspects of solution delivery, sample preconcentration and signal processing. Detection limits currently obtainable with this system are 0.1 ng ml-1 HgO.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Part I - Fluorinated Compounds A method has been developed for the extraction, concentration, and determination of two unique fluorinated compounds from the sediments of Lake Ontario. These compounds originated from a common industrial landfill, and have been carried to Lake Ontario by the Niagara River. Sediment samples from the Mississauga basin of Lake Ontario have been evaluated for these compounds and a depositional trend was established. The sediments were extracted by accelerated solvent extraction (ASE) and then underwent clean-up, fractionation, solvent exchange, and were concentrated by reduction under nitrogen gas. The concentrated extracts were analyzed by gas chromatography - electron capture negative ionization - mass spectrometry. The depositional profile determined here is reflective of the operation of the landfill and shows that these compounds are still found at concentrations well above background levels. These increased levels have been attributed to physical disturbances of previously deposited contaminated sediments, and probable continued leaching from the dumpsite. Part II - Polycyclic Aromatic Hydrocarbons Gas chromatography/mass spectrometry is the most common method for the determination of polycyclic aromatic hydrocarbons (PAHs) from various matrices. Mass discrimination of high-boiling compounds in gas chromatographic methods is well known. The use of high-boiling injection solvents shows substantial increase in the response of late-eluting peaks. These solvents have an increased efficiently in the transfer of solutes from the injector to the analytical column. The effect of I-butanol, I-pentanol, cyclopentanol, I-hexanol, toluene and n-octane, as injection solvents, was studied. Higher-boiling solvents yield increased response for all PAHs. I -Hexanol is the best solvent, in terms of P AH response, but in this solvent P AHs were more susceptible to chromatographic problems such as peak splitting and tailing. Toluene was found to be the most forgiving solvent in terms of peak symmetry and response. It offered the smallest discrepancies in response, and symmetry over a wide range of initial column temperatures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Chronic low back pain (CLBP) is a complex health problem of psychological manifestations not fully understood. Using interpretive phenomenological analysis, 11 semi-structured interviews were conducted to help understand the meaning of the lived experience of CLBP; focusing on the psychological response to pain and the role of depression, catastrophizing, fear-avoidance behavior, anxiety and somatization. Participants characterized CLBP as persistent tolerable low back pain (TLBP) interrupted by periods of intolerable low back pain (ILBP). ILBP contributed to recurring bouts of helplessness, depression, frustration with the medical system and increased fear based on the perceived consequences of anticipated recurrences, all of which were mediated by the uncertainty of such pain. During times of TLBP all participants pursued a permanent pain consciousness as they felt susceptible to experience a recurrence. As CLBP progressed, participants felt they were living with a weakness, became isolated from those without CLBP and integrated pain into their self-concept.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent research suggests that participating in vigorous synchronized physical activity may result in elevated levels of endorphins, which may in turn affect social bonding (Cohen et. al., 2009). The present research aimed to examine whether or not the change in pain tolerance would be able to predict participants’ willingness to cooperate after statistically controlling for the groups’ condition. Participants were asked to run on a treadmill for 30 minutes under one of two conditions (control vs. synchronized). Prior to and after the run participants underwent a pain tolerance test. Once completed, a second activity was introduced to the participants; a cooperative game. A public goods game was used to measure an individual’s willingness to cooperate. The results showed the synchronized condition was able to predict that participants cooperated more during the public goods game (p = .009), however the change in pain threshold was unable to significantly predict cooperation (p = .32).