2 resultados para Immunoglobulins, Intravenous

em Brock University, Canada


Relevância:

20.00% 20.00%

Publicador:

Resumo:

It is common practice to initiate supplemental feeding in newborns if body weight decreases by 7-10% in the first few days after birth (7-10% rule). Standard hospital procedure is to initiate intravenous therapy once a woman is admitted to give birth. However, little is known about the relationship between intrapartum intravenous therapy and the amount of weight loss in the newborn. The present research was undertaken in order to determine what factors contribute to weight loss in a newborn, and to examine the relationship between the practice of intravenous intrapartum therapy and the extent of weight loss post-birth. Using a cross-sectional design with a systematic random sample of 100 mother-baby dyads, we examined properties of delivery that have the potential to impact weight loss in the newborn, including method of delivery, parity, duration of labour, volume of intravenous therapy, feeding method, and birth attendant. This study indicated that the volume of intravenous therapy and method of delivery are significant predictors of weight loss in the newborn (R2=15.5, p<0.01). ROC curve analysis identified an intravenous volume cut-point of 1225 ml that would elicit a high measure of sensitivity (91.3%), and demonstrated significant Kappa agreement (p<0.01) with excess newborn weight loss. It was concluded that infusion of intravenous therapy and natural birth delivery are discriminant factors that influence excess weight loss in newborn infants. Acknowledgement of these factors should be considered in clinical practice.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Euclidean distance matrix analysis (EDMA) methods are used to distinguish whether or not significant difference exists between conformational samples of antibody complementarity determining region (CDR) loops, isolated LI loop and LI in three-loop assembly (LI, L3 and H3) obtained from Monte Carlo simulation. After the significant difference is detected, the specific inter-Ca distance which contributes to the difference is identified using EDMA.The estimated and improved mean forms of the conformational samples of isolated LI loop and LI loop in three-loop assembly, CDR loops of antibody binding site, are described using EDMA and distance geometry (DGEOM). To the best of our knowledge, it is the first time the EDMA methods are used to analyze conformational samples of molecules obtained from Monte Carlo simulations. Therefore, validations of the EDMA methods using both positive control and negative control tests for the conformational samples of isolated LI loop and LI in three-loop assembly must be done. The EDMA-I bootstrap null hypothesis tests showed false positive results for the comparison of six samples of the isolated LI loop and true positive results for comparison of conformational samples of isolated LI loop and LI in three-loop assembly. The bootstrap confidence interval tests revealed true negative results for comparisons of six samples of the isolated LI loop, and false negative results for the conformational comparisons between isolated LI loop and LI in three-loop assembly. Different conformational sample sizes are further explored by combining the samples of isolated LI loop to increase the sample size, or by clustering the sample using self-organizing map (SOM) to narrow the conformational distribution of the samples being comparedmolecular conformations. However, there is no improvement made for both bootstrap null hypothesis and confidence interval tests. These results show that more work is required before EDMA methods can be used reliably as a method for comparison of samples obtained by Monte Carlo simulations.