3 resultados para H3 Relaxin
em Brock University, Canada
Resumo:
Euclidean distance matrix analysis (EDMA) methods are used to distinguish whether or not significant difference exists between conformational samples of antibody complementarity determining region (CDR) loops, isolated LI loop and LI in three-loop assembly (LI, L3 and H3) obtained from Monte Carlo simulation. After the significant difference is detected, the specific inter-Ca distance which contributes to the difference is identified using EDMA.The estimated and improved mean forms of the conformational samples of isolated LI loop and LI loop in three-loop assembly, CDR loops of antibody binding site, are described using EDMA and distance geometry (DGEOM). To the best of our knowledge, it is the first time the EDMA methods are used to analyze conformational samples of molecules obtained from Monte Carlo simulations. Therefore, validations of the EDMA methods using both positive control and negative control tests for the conformational samples of isolated LI loop and LI in three-loop assembly must be done. The EDMA-I bootstrap null hypothesis tests showed false positive results for the comparison of six samples of the isolated LI loop and true positive results for comparison of conformational samples of isolated LI loop and LI in three-loop assembly. The bootstrap confidence interval tests revealed true negative results for comparisons of six samples of the isolated LI loop, and false negative results for the conformational comparisons between isolated LI loop and LI in three-loop assembly. Different conformational sample sizes are further explored by combining the samples of isolated LI loop to increase the sample size, or by clustering the sample using self-organizing map (SOM) to narrow the conformational distribution of the samples being comparedmolecular conformations. However, there is no improvement made for both bootstrap null hypothesis and confidence interval tests. These results show that more work is required before EDMA methods can be used reliably as a method for comparison of samples obtained by Monte Carlo simulations.
Resumo:
The present study has both theoretical and practical aspects. The theoretical intent of the study was to closely examine the relationship between muscle activity (EMG) and EEG state during the process of falling asleep. Sleep stages during sleep onset (SO) have been generally defined with regards to brain wave activity (Recht schaff en & Kales (1968); and more precisely by Hori, Hayashi, & Morikawa (1994)). However, no previous study has attempted to quantify the changes in muscle activity during this same process. The practical aspect of the study examined the reliability ofa commercially developed wrist-worn alerting device (NovAlert™) that utilizes changes in muscle activity/tension in order to alert its user in the event that he/she experiences reduced wakefulness that may result in dangerous consequences. Twelve female participants (aged 18-42) sp-ent three consecutive nights in the sleep lab ("Adaptation", "EMG", and "NOVA" nights). Each night participants were given 5, twenty-minute nap opportunities. On the EMG night, participants were allowed to fall asleep freely. On the NOV A night, participants wore the Nov Alert™ wrist device that administered a Psychomotor Vigilance Test (PVT) when it detected that muscle activity levels had dropped below baseline. Nap sessions were scored using Hori's 9-stage scoring system (Hori et aI, 1994). Power spectral analyses (FFT) were also performed. Effects ofthe PVT administration on EMG and EEG frequencies were also examined. Both chin and wrist EMG activity showed reliable and significant decline during the early stages ofHori staging (stages HO to H3 characterized by decreases in alpha activity). All frequency bands studied went through significant changes as the participants progressed through each ofHori's 9 SO stages. Delta, theta, and sigma activity increased later in the SO continuum while a clear alpha dominance shift was noted as alpha activity shifted from the posterior regions of the brain (during Hori stages HO to H3) to the anterior portions (during Hori stages H7 to H9). Administration of the PVT produced significant increases in EMG activity and was effective in reversing subjective drowsiness experienced during the later stages of sleep onset. Limitations of the alerting effects of the PVTs were evident following 60 to 75 minutes of use in that PVTs delivered afterwards were no longer able to significantly increase EMG levels. The present study provides a clearer picture of the changes in EMG and EEG during the sleep onset period while testing the efficacy of a commercially developed alerting device. EMG decreases were found to begin during Hori stage 0 when EEG was - dominated by alpha wave activity and were maximal as Hori stages 2 to 5 were traversed (coincident with alpha and beta activity). This signifies that EMG decrements and the loss of resting alpha activity are closely related. Since decreased alpha has long been associated with drowsiness and impending sleep, this investigation links drops in muscle tone with sleepiness more directly than in previous investigations. The EMG changes were reliably demonstrated across participants and the NovAlert™ detected the EMG decrements when Hori stage 3 was entered. The alerting vibrations produced by the NovAlert™ occurred early enough in the SO process to be of practical importance as a sleepiness monitoring and alerting device.
Resumo:
I t was hypothesized that the freeze/thaw cycles endured by icewine grapes would change their chemical composition, resulting in unique chemical fingerprint and sensory properties, and would be affected by harvest date (HD) and crop level (CL). The objectives were: 1) to identify odour-active compounds using gas chromatographic and sensory analysis; 2) to determine the effect of CL and HD on these compounds; 3) to determine the icewine sensory profiles; 4) to correlate analytical and sensory results for an overall icewine profile. CharmAnalysis™ determined the Top 15 odour-potent compounds in Vidal and Riesling icewine and table wines; 24 and 23 compounds, respectively. The majority of the compounds had the highest concentrations in the icewines compared to table wines. These compounds were used as the foundation for assessing differences in icewine chemical profiles from different HD and CL. Vidal and Riesling icewine were made from grapes picked at different HD; HI : 19 December; H2: 29 December; H3: 18 January; H4: 11 February (Vidal only). HI wines differed from H3 and H4 wines in both Vidal and Riesling for aroma compounds and sensory profiles. - Three·CL [control (fully cropped), cluster thin at fruit set to one basal cluster/shoot (TFS), and cluster thin at veraison to one basal cluster/shoot (TV)] were evaluated for Riesling and Vidal cultivars over two seasons. Vidal icewines had the highest concentration of aroma compounds in the control and TV icewines in 2003 and in TFS icewines in 2004. In Riesling, most aroma compounds had the highest concentration in the TV icewines and the lowest concentration in the TFS wine for both years. The thinned treatments were associated with almost all of the sensory attributes in both cultivars, both years. HD and CL affected the chemical variables, aroma compounds and sensory properties of Vidal and Riesling icewines and freeze/thaw events changed their sensory profile. The most odour-potent compounds were p-damascenone, cis-rose oxide, 1- octen-3-ol, 4-vinylguaiacol, ethyl octanoate, and ethyl hexanoate. The role of Pdamascenone as a marker compound for icewine requires further investigation. This research provides a strong foundation for the understanding the odour-active volatiles and sensory profiles important to icewine.